Aico RadioLink Ei208DWRF User manual

Mile End Business Park, Oswestry, Shropshire SY10 8NN Tel. 0870 758 4000 Fax. 0870 758 4010 www.aico.co.uk
E &OE Our policy is one of continuous improvement. Ei208DWRF DataSht Rev 2 20.06.12
We reserve the right to amend designs and specifications without prior notice.
Product Description
The Ei208DWRF is a RadioLINK Carbon Monoxide (CO) Alarm
that is powered by a sealed-in Lithium battery.
The alarm has a high performance, proven electrochemical
sensor to sense CO presence. The sensor is individually
calibrated and tested in CO gas on assembly to ensure
accuracy.
The LCD displays CO level, status messages and icons.
The alarm has RadioLINK interconnectivity which enables
wireless transmission of a CO alarm condition to other
RadioLINK alarms and accessories.
The alarm has a twist on mounting base which has multiple
fixing points so it can easily be secured to a ceiling or wall.
The memory feature records the last CO level sensed and can
be useful to check if CO has been present if the home owner
or tenant has been absent from the property.
An easy to use Test/Hush button allows the user to test the
alarm. This checks all aspects of the alarm (sensor, electronics
and sounder).
The alarm has an ‘End of life’ indicator which will notify the
user when the alarm needs replacing at the end of its seven
year life.
Operation
When dangerous levels of CO are detected, the LCD will
display the CO concentration, the alarm will sound and the
red alarm light will flash as detailed below:
When lower levels of CO are detected, the alarm will display
a ‘VENTILATE’ message. When higher levels are detected, the
alarm will display an ‘EVACUATE’ message
If the alarm is reaching the end of life or a sensor fault is
detected the alarm will display a ‘REPLACE UNIT’ message
and the amber fault light will flash three times every minute
with three beeps
The ‘Test/Hush’ button will either silence false alarms (if
briefly pressed) or perform a unit self test (if pressed and
held). Note that the alarm cannot be silenced when sensing
a CO level of 150ppm or above
Lithium Battery Powered
Carbon Monoxide Alarm
Wireless interconnection to RadioLINK Smoke, Heat and Carbon
Monoxide (CO) alarms and accessories
Proven Electrochemical sensor (7 year life)
Lithium battery (sealed in)
Easy to use large Test/Hush button
LCD displays CO level, status messages and icons
Memory feature records if Carbon Monoxide (CO) has been detected
Pre alarm LED and LCD display gives early warning of CO
Loud distinctive alarm sound (85db (A) at 3 metres)
Power, alarm and fault indicator lights
Kitemarked to BS EN50291-1:2010
5 Year Guarantee
Model Ei208DWRF
CO Level Red Light Alarm
<43ppm Off Off
43-80ppm 1 flash every 2 sec Sounds after 60-90 mins
80-150ppm 1 flash every sec Sounds after 10-40 mins
>150ppm 2 flashes every sec Sounds within 2 mins
Wireless Interconnection

Technical Specification
1. The CO Alarm carries the BSI Kitemark to indicate type testing to BS EN 50291-1:2010. It is CE marked to indicate conformance to BS EN 60335-1:1994,
BS EN 50270:1999 Safety and Electromagnetic Compatibility Directives.
2. New generation electrochemical cell type Carbon Monoxide sensor checks CO concentration every 4 seconds. Each unit is calibrated and tested in CO gas
in order to ensure accuracy.
3. Battery powered. Sealed in Lithium battery that will power the unit for it’s entire life (7 years). The LCD will display a Low Battery indicator and the
amber fault light will flash twice every minute with two beeps to indicate that the unit needs replacing.
4. Start up sequence - the red, amber and green LEDs will flash once. Rapid warm up time - once this very short sequence has elapsed, the alarm is in full
operation.
5. CO level indicators as follows. The LCD display will also show the actual CO level in parts per million (PPM):
6. Fault indicator - the LCD will display a ‘REPLACE UNIT’ message and the amber fault light will flash twice every 50 seconds if a fault is detected.
7. Manual Test/Hush button - press and hold the Test/Hush button to test circuitry, sensor and sounder. LEDs will flash as below:
Normal mode - Green LED flash with normal alarm sound
Fault condition - Amber LED flash. Alarm will not sound
End of life - Amber LED flash with beep
10. Pressing and releasing the Test/Hush button when the unit is sensing CO will silence the alarm for 4 minutes. It will only silence once until the gas clears.
At CO levels of 150ppm and above the unit cannot be silenced due to the increased danger.
11. Memory feature which records the last CO level sensed. If the unit has been in alarm and then ceased, the red LED will continue to flash for a 24 hour
period to indicate the level of CO sensed. Pressing the test button will also show the last CO level sensed, via the rate of flash of the red LED. As follows:
12. Built in sounder to give a minimum output of 85dB(A) at 3 metres. Modulated sound output - 3 rapid pulses followed by a 1½ second pause, repeated
until reset. This easily differentiates it from a typical smoke alarm.
13. Automatic reset of alarm test function and after an alarm state when CO gas clears.
14. Radio frequency (wireless) interconnection: 868 MHz band in accordance with R&TTE Directive 1999/5/EC - this band has been designated for use with
security products and only allows a 1% duty cycle, so continuous transmission and interference from external sources is extremely remote, and would be
illegal.
15. RF Range: the type of building will be the major limiting factor i.e. the number and type of walls/ceilings that the radio signal has to pass through. As a
guide, 30m should be the maximum distance between any alarms in the system.
16. Up to 12 units can be installed on one system. For larger systems contact our Technical Service Department for guidance.
17. Units are in Factory Code when received (they will all communicate with each other). They must be ‘House-Coded’ to eliminate the risk of adjacent
properties communicating with each other. After ‘House-Coding’ they will only communicate with other units coded at the same time.
14. Supplied with integral mounting base and fixing screws. The mounting base has multiple fixing holes and the alarm is suitable for ceiling or wall
mounting.
15. Operating temperature range: -10°C to +40°C. 15% to 95% relative humidity (non-condensing).
16. Dimensions: 120mm x 105mm x 45mm. Weight: 180g.
17. 5 year guarantee.
18. Manufactured in Ireland.
Mile End Business Park, Oswestry, Shropshire SY10 8NN Tel. 0870 758 4000 Fax. 0870 758 4010 www.aico.co.uk
E &OE Our policy is one of continuous improvement. Ei208DWRF DataSht Rev 2 20.06.12
Aico Ltd is a wholly owned subsidiary of Ei Electronics
Europe’s Leader in Residential Fire + Gas Detection
Ei Electronics, Shannon, Ireland
Made in
Ireland
Model Ei208DWRF
CO Level Red Light LCD Display (before horn
sounds)
<43ppm Off Off
43-80ppm 1 flash every 2 sec VENTILATE
80-150ppm 1 flash every sec VENTILATE
>150ppm 2 flashes every sec VENTILATE
LCD Display (after horn
sounds)
Off
EVACUATE
EVACUATE
EVACUATE
Alarm
Off
Sounds after 60-90 mins
Sounds after 10-40 mins
Sounds within 2 mins
For 24 hours after the alarm has ceased
CO Level Sensed Red Light
43-80ppm 2 flashes every 50 sec
80-150ppm 4 flashes every 50 sec
>150ppm 8 flashes every 50 sec
When the test button is pressed
CO Level Sensed Red Light
43-80ppm 1 flash every 2 sec
80-150ppm 1 flash every sec
>150ppm 2 flashes every sec
LCD Display
Displays previous CO level in ppm
Displays previous CO level in ppm
Displays previous CO level in ppm