WARRANTY
The benets conferred by this warranty are in addition to all implied warranties, other rights
and remedies in respect of the product which the consumer has under the Trade Practices
Act and similar State and Territory Laws.
The original purchaser of this Threesome, is provided with the following warranty, subject
to the following conditions. Gerard Industries Pty Ltd warrants this product for a period
of 5 years from the date of purchase for all parts defective in workmanship or materials.
All defective parts will be repaired at the point of installation, free of charge. Commercial
applications are covered by this warranty and its conditions for 90 days only.
WARRANTY CONDITIONS
1. This warranty is only valid for appliances installed according to the manufacturer’s instructions.
2. This appliance must not be modied or changed in any manner.
3. All wiring must be carried out by a qualied electrician and must be connected to the voltage
requirements as specied in the ratings label.
4. Heater Globes supplied with this unit are covered by a separate 2 year replacement warranty
and excluded from the 5 year In-Home warranty. The Incandescent, R80 centre globe is
excluded from all the above warranties.
5. The manufacturer does not accept liability for any direct or consequential damage, loss or
other expense arising from misuse or incorrect installation and operation of the appliance.
6. Warranty will only be given on appliances where proof of purchase is provided, e.g. original
invoice.
IMPORTANT: RETAIN YOUR RECEIPT. To obtain In-Home service under warranty you must
retain your original purchase receipt. Service will otherwise be charged at current rates.
For your future reference, please complete the following details and le this
information with your purchase invoice.
Threesome Model 6500ATP.
Serial Number
Purchased From
Date of Purchase
SPARE PARTS
Electrical switches supplied with your Threesome are usually available from any electrical
wholesaler. The central globe can be replaced by a 100W maximum reector type, R80,
screw in globe. The special Hard Glass heating globes are only available from selected
retailers and wholesalers.
Note: Maximum wattage of central light globe is 100 watts.
Maximum wattage of each heat globe is 275 watts.
SERVICE AND MAINTENANCE (within Australia)
For service or maintenance within Australia, contact the following specialist service provider:
Electric Blue Installations & Service Pty. Ltd.
To ensure prompt service or maintenance of your product(s) please have the following
information available prior to phoning Electric Blue.
• Model number and description of the product(s).
• Detailed description of the problem or maintenance requirements.
• For warranty enquiries please ensure you also have proof of purchase (i.e. receipt).
Phone 1300 654 488
For service within New Zealand, contact CLIPSAL NZ on (09) 576 1757
F1678/02
Product of Gerard Industries Pty Ltd
ABN 27 007 873 529
Head Ofce 12 Park Terrace, Bowden, SA 5007
Telephone (08) 8269 0511 Facsimile (08) 8340 1724
E-mail [email protected]
Double Insulated
New Zealand Clipsal Industries (NZ) Ltd (Auckland)
Telephone (09) 576 3403 Facsimile (08) 576 1015
E-mail headof[email protected].nz
Customer Service Free Fax (0508) 250 305
Auckland/Mobile Phone (09) 572 0014
Free Phone (0508) CLIPSAL
2547725
© Copyright Gerard Industries Pty Ltd 2003 IMPORTANT
THESE INSTRUCTIONS ARE ALSO YOUR
INSTALLATION TEMPLATE
Installation Instructions and Warranty
Radiant Globe Combination
Heater, Light and Exhaust Fan
Threesome
6500ATP
FITTING INSTRUCTIONS
Thank you for purchasing this Threesome product by Gerard Industries Pty Ltd. Threesome
combines heat globes, an exhaust fan and light, to provide gentle radiant heat, clean air and
a bright light from one compact, stylish unit. All functions are separately controlled from a
supplied switch plate for convenient ngertip control.
You can be assured of years of trouble free operation by installing your Threesome carefully
according to instructions. Please read all instructions before commencing installation.
Threesome can be mounted in any room that requires instant, direct, radiant heat to ward
off winter chills. The light and fan have separate switching, making it suitable for bathrooms,
dressing & change rooms.
BV`SSa][S
SUITABLE LOCATIONS
The Threesome has been designed especially for cavity type ceilings. Flat roof installation is
NOT recommended.
Threesome must not be mounted in areas subject to direct splashing. Threesome must
be mounted in the horizontal position only. Unsuitable for ‘cathedral’ or ‘raked’ ceilings.
Threesome comes with 4 Infra-red Heat Globes which emit harmless radiant heat.
Threesome is best positioned directly above the area requiring warmth. Before you start,
make sure your ceiling has at least 280mm clearance from the roof (see diagram 2).
WHERE TO LOCATE
Radiant globe heaters are not designed to heat entire rooms. They provide instant,
concentrated heat to persons standing directly below the heat lamps. Therefore, units should
be located over the area where drying off takes place, not directly over a shower
or bath.
These heaters are not designed to be left on for extended periods of time, as this could
cause overheating and premature failure. Threesome units, even those without fans, should
not be covered or installed in situations which restrict the natural ventilation of the units for
cooling purposes.
Ceiling insulation should be kept well clear of the units (at least 100mm). For optimum
performance, models with exhaust fans should be installed in areas with good ventilation,
to enable fresh air to ow into the room. It is recommended that there is at least a 500mm
clearance above the unit, and that the ceiling space is adequately ventilated to allow
appropriate air ow through the unit. Any restrictions on return air entering the room, or
exhausted air escaping from the ceiling space, will impair effectiveness and may contribute to
premature failure.
RADIANT HEAT
Threesome requires no warm up period because of its efcient, Radiant Heat Globes. Heat
is directed at you for an instant warmth you can feel, rather than gradually warming the entire
room. Because of this, Threesome only needs to be turned ON when you are in the room.
MOUNTING
1. Using this card in its open state as a template, position it
in the area you want your Threesome and draw around
the edges with a pencil to mark the hole cutting size.
BE SURE TO CHECK ABOVE THE CEILING FOR
MINIMUM SPACE OF 280mm (for optimum performance
allow 500mm or more clearance) AND THE LOCATION
OF THE CEILING JOISTS. Ensure there is a minimum
of 100mm clear space between the Threesome unit and
any ceiling insulation.
2. Use a saw to cut the section along the drawn lines.
3. The lamp surround easily unclips from the main body
by lifting gently from any side. Remove it and the 4 heat
globes to avoid damage from knocks and vibrations.
Now insert your Threesome with both side springs pulled
inwards so that the body can pass through the hole
without damaging the plaster. Return springs to original
position to x body securely to the ceiling.
NOTE: Springs are adjusted to suit either 10mm or 13mm
plasterboard ceiling.
4. Clip the lamp surround back onto the body making sure
both clips snap into place. Fit retaining spring as shown
in diagram.
5. The lamp surround has been shaped to position heat
globes correctly in the main body. Screw the four, large
heat globes through the lamp surround holes, tightening
rmly to ensure a good electrical contact. DO NOT
FORCE OR OVER-TIGHTEN. Screw centre light globe
into place. Centre lampholder is designed to accept 100
Watt (max), reector type, R80, screw in light globes.
IMPORTANT SAFEGUARDS
• The Threesome is not intended for use by young children or inrm persons without supervision
.
• Young children should be supervised to ensure that they do not play with the appliance.
• Ensure that the switch is in the off position when changing the heat lamp (globe) or light globe.
• Ensure that the wattage of a replacement globe is the same as the globes supplied with the unit.
• Ensure the grille is free of objects, dust build up, etc. Make sure that the air ow through the
grille is not inhibited.
ELECTRICIANS’ WIRING INSTRUCTIONS
Your Threesome requires a 230/240 Volt, 50Hz electrical supply. All electrical work must
be carried out by a qualied electrician and installed in accordance with relevant Electrical
Wiring Regulations.
Your new Threesome comes with all required switches and mounting plate.
WIRING DETAILS
1. Decide the best position for the switch set and mount it. Be sure to click the switches into
the backing plate in the desired order beforehand.
2. Connect wiring to switches as shown in the appropriate electrical diagram.
3.
Remove screws from
terminal cover on the
Threesome and put aside.
Wire according to the
label beside the terminal
strip. Once the wires
are connected incoming
cable must not be fouled
by cover. Use appropriate
knockouts in terminal
cover to accommodate
cable before replacing.
Screw down rmly.
TEST
Clean surround and globes with a soft, moist cloth. Check power is switched on and all
switches activate properly, according to their marked function.
CLEANING
• Ensure the Threesome is switched off before cleaning.
• Remove globes when they are at room temperature. Wipe with a damp cloth, never immerse.
• Unclip lamp surround and wash in warm, soapy water. Always use a soft cloth, never abrasives.
•
Clean away any excess uff from the inside of the body, motor blade brackets.
PERMANENT
APPLIANCE
WIRING
E
NEUTRAL
HEAT
FAN
HEAT
LIGHT
SWITCHES EARTH
ACTIVE

Other Airflow Heater manuals

Airflow EPO-V Series Reference manual

Airflow

Airflow EPO-V Series Reference manual

Airflow SunShine 6600ATP User manual

Airflow

Airflow SunShine 6600ATP User manual

Popular Heater manuals by other brands

Master MH-40-GFA User's manual & operating instructions

Master

Master MH-40-GFA User's manual & operating instructions

Holmes HCH5250 owner's guide

Holmes

Holmes HCH5250 owner's guide

Black & Decker BDH55 Use and care book

Black & Decker

Black & Decker BDH55 Use and care book

Rointe KYROS KTI030SE 3 Series instruction manual

Rointe

Rointe KYROS KTI030SE 3 Series instruction manual

Vortice VORT HRW 60 HP MONO Instruction booklet

Vortice

Vortice VORT HRW 60 HP MONO Instruction booklet

DAY Useful Everyday 69651 instruction manual

DAY Useful Everyday

DAY Useful Everyday 69651 instruction manual

Decofire DF102043 Assembly, Safety & Operating Instructions

Decofire

Decofire DF102043 Assembly, Safety & Operating Instructions

Telemax DRO 128 9FINS manual

Telemax

Telemax DRO 128 9FINS manual

BVF Heating Solutions CALEO CP1-500 user manual

BVF Heating Solutions

BVF Heating Solutions CALEO CP1-500 user manual

Protemp Protemp PT-45-KFA Owner's Manual and Operating Instructions

Protemp

Protemp Protemp PT-45-KFA Owner's Manual and Operating Instructions

ApenGroup AH-Sport manual

ApenGroup

ApenGroup AH-Sport manual

HK Instruments DPT-Flow-4 Series installation instructions

HK Instruments

HK Instruments DPT-Flow-4 Series installation instructions

SKF EAZ Instructions for use

SKF

SKF EAZ Instructions for use

Mesko MS7804 user manual

Mesko

Mesko MS7804 user manual

Master B 230 User and Maintenance Book

Master

Master B 230 User and Maintenance Book

Klarstein 10031979 manual

Klarstein

Klarstein 10031979 manual

Smith's Heating First Sterling 3 EL Installation & user guide

Smith's Heating First

Smith's Heating First Sterling 3 EL Installation & user guide

Clarke CONTRACTOR GSH15 Operation & maintenance instructions

Clarke

Clarke CONTRACTOR GSH15 Operation & maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.