Airzone SE80RVL User manual

VENTILATION FAN
TM
Model: SE80RVL SE80RVLH
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switching on
accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, tothe service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated
construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and
the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT
THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the
motor with the exact service motor. The impeller should also be replaced.
OPERATION
Use an on/off switch to operate this fan. See “Connect Wiring” for details.
The humidity control and fan can be operated separately. Use a 1 or 2 function wall control. Do not use a dimmer switch to operate the
humidity control or light. See “Connect Wiring” for details.
For SE80RVLH
SENSOR OPERATION
The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable) increases in humidity or
(b) humidity above a user-adjustable set-point (50%-100% relative humidity). The humidity sensor may occasionally turn the fan ON when
environmental conditions change. If the fan continuously responds to changing environmental conditions, “H” (means “humidity”) adjustment
may be required. This figure is factory-set for about 75% (Ambient temperature of 25¥)
SENSITIVITY ADJUSTMENT
The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness control, the “H”
may need to be increased toward maximum “+”. If the control is responding too often to changing environmental conditions, movement toward less
“-” “H” may be required.
To adjust the “H”:
1. Disconnect power at service entrance.
2. Through the grille, locate the slot marked “H”.
3. Carefully rotate the “H” adjustment toward “+” or “-”.
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on.
5. Repeat above steps if necessary.
When the temperature changes, humidity sensor values will have deviation.
TIMER ADJUSTMENTC
The humidity sensing fan has a “T” (means timer) that can be adjusted from 5 to 60 minutes (factory-set at about 20 minutes). This “T” controls the
length of time that the fan remains ON afterthe sensor has stopped sensing a rise in humidity and the humidity level is below the user-adjustable set-point.
To adjust the “T”:
1. Disconnect powerat service entrance;
2. Through the grille, locate the slot marked “T”;
3. Carefully rotate the “T” adjustment to desired setting (from 5 to 60 minutes).
4. Check operation by turning on ahumidity source until the fanturns on.
5. Turn humiditysource off and time the unit.
6. Repeat above steps if necessary.
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.

PLAN THE INSTALLATION
1. Do not use in a cooking area.
2. Two ways to connect ductwork to a factory-shipped unit.
ROOF CAP *
ROUND
DUCT *
*Purchase
separately
ROUND WALL
CAP *
ELBOW *
ASSEMBLY INSTRUCTIONS
1. Befor installation, you need to know:
Screw A ST4.2*13mm
Screw B ST4.2*25mm
Hanger bar 13 3/8 in (340mm)
(long)
14 3/8 in.-23 1/2 in. (365-597)
1. MOUNT WITH HANGER BARS
1a. Sliding hanger bars have been provided, which allow the housing to be
positioned accurately anywhere between the framing. The bars can be used
on all types of framing: I-joist, standard joist,
and truss construction. Slide hanger bars onto housing and adjust as
needed to fit between framing.
1b. Extend the hanger bars to the width of the framing. Position the Screw A
ventilator with the hanger bar tabs wrapped around the bottom edge of the
framing, holding the ventilator in place.
Secure hanger bars to framing using one screw on each end of hanger bar.
Select a proper hole and secure the hanger bars together using flange
screws.
Screw B
2

ASSEMBLY INSTRUCTIONS
2. INSTALL ROUND DUCTWORK
Connect the round ductwork (not included) to the damper/duct connector,
and run the ductwork to a roof or wall cap (not included). Using tape (not
included), secure all the ductwork connections so that they are air tight.
CONNECT ELECTRICAL WIRING
Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the wiring
plate. Refer to the wiring diagram, and connect the wires as shown.
SE80RVL
BLACK(BLK) WHITE(WHT)
BLUE(BLU) GROUND (GRD)
LIGHT WIRE PANEL UNIT
FAN
SE80RVLH
FAN BLK
SWITCH COM WHT
SENSOR BRN
SWITCH BLK
WHT
LIGHT BLU
SWITCH WHT
SWITCH BOX FAN LIGHT
RECEPTACLE RECEPTACLE
POWER SUPPLY
120V AC
BLACK (BLK) WHITE (WHT) BLUE(BLU)
BROWN (BRN) GROUND (GRD)
SENSOR WIRE PANEL UNIT
HUMIDITY
L RECEPTACLE
T LIGHT
Motor
N H FAN
LIGHT FAN LIGHT
BLK
LINEWHT
IN GRD
SWITCH BOX UNIT
SWITCH BOX RECEPTACLE
RECEPTACLE
120V AC LINE IN
FINISH CEILING WORK
1. A circle ceiling hole (6 1/2 inches (165mm) dia.) shoule be cut. And
make sure there will be a gap (> 1/8 inches (3.2mm))between bottom
of fan body and ceiling. Lamp base
Install the fluorescent lamp.
Note: The lamp base can adjust the height in 2.6 in. to 4 in. (66mm-102mm)
with the wing nut on both side of the lamp base.
Wing nut
Fluorescent lamp
Joist
Hanger bar
Ceiling
After finishing the ceiling job, fill gap between flange and ceiling with caulk or
other sealant to pervent air leakage.
REPLACEMENT INSTALLATION
1. Remove the trim ring by pulling down the springs.
2. Remove the screws as shown in the right.
3. Remove the lamp base.
4. Pull the duct system, so that you can see the blowe system.
Remove the screws
Blowe system
Lamp base
3

REPLACEMENT INSTALLATION
5. Remove the screws as shown in the right.
6. Take the blowe system out of the housing.
7. Replace the broken parts.
8. Replace the capacitance need to remove the wire panel, and then
replace the capacitance.
Remove the screws
Remove the screws
Remove
the screws Wire Panel
SERVICE PARTS
PART PART NAME Qty. 12
1 Trim Ring 1
2 Lamp base 1
3 Humidity Sensor System (for SE80RVLH) 1 11 6
4 Wire Panel / Harness Assembly 1 5
5 Hanger Bars 4
6 Wiring plate 1 5
7 Motor 1 4
8 Motor plate 1 10
9 Blower Wheel 1 3
10 Blower housing 1 9
11 Duct 1 2
12 Housing 1 8 1
7
WARRANTY
This warranty covers all defects in workmanship or materials for:
The mechanical and electrical parts contained in this product, for a period of 12 months, from the date of purchase. You must keep and be able to provide your
original sales receipt as proof of the date of purchase. This warranty is covered the original retail purchaser of this product. The manufacturer will repair or
replace, in your home, any mechanical or electrical part which proves defective in normal household use for a period of 12 months.
THIS WARRANTY DOES NOT COVER:
• Damages from improper installation
• Damages from shipping
• Damages from misuse, abuse, accident, alteration, lack of proper care and maintenance
• Damages from service by persons other than an authorized dealer or service center.
• Labor, service, transportation and shipping charges for the removal of defective parts and for installation of a replacement part,
beyond the initial 12-month period.
This warranty does not extend to fluorescent lamp starters and tubes.
THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
The remedyprovidedin this warranty is exclusive and is granted in lieu of all other remedies. This warranty does not cover incidental or consequential damages.
Some states do not allow the exclusion of incidental or consequential damages, so this limitation may not apply to you. Some states do not allow limitations on how
long an implied warranty lasts, so this limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which
vary from state to state.
4
This manual suits for next models
1
Table of contents
Other Airzone Fan manuals
Popular Fan manuals by other brands

Carrier
Carrier 42BJ ULTRA installation instructions

Brandson
Brandson 303030 user manual

Quoizel
Quoizel PCOH3120OI installation guide

EFBE-SCHOTT
EFBE-SCHOTT VT 800 Operaing instructions

Home Decorators Collection
Home Decorators Collection AJAX 51770 Use and care guide

Ensy
Ensy AHU-300 HV User manual and installation guide

LUCCI Air
LUCCI Air AIRFUSION MOONAH Series Installation instructions & warranty information

Hunter
Hunter 23947 Manual de Installatión y Operatión

Vitek
Vitek VT-1913 Manual instruction

HiB
HiB Hush Series Fitting instructions

RH Teen
RH Teen Zephyr 52 quick start guide

Panasonic
Panasonic Whisper Value-Lite FV-08VSL2 installation instructions