manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. AKO
  6. •
  7. Transmitter
  8. •
  9. AKO DP Series User manual

AKO DP Series User manual

®
Sensor and Equipment
Differential Pressure Transmitter
DP Series
Instruction Manual
Please read the following
safety considerations before use.
Safety considerations
Please observe all safety considerations for safe and
proper product operation to avoid hazards.
Warning: Fail-safe device must be installed when using
the unit with machinery that may cause serious injury or
economic loss.(e.g. nuclear power control, medical equipment,
ships, railways, aircraft, combustion, safety equipment, etc.)
Warning: Do not connect, repair or inspect the unit while
connected to a power source.
Warning: Do not disassemble or modify the unit, please
contact us if necessary.
Warning: check input power specification and check power
terminal polarity before connecting the power source.
Caution: Do not use the unit outdoors.
Caution: Do not touch the temperature \ humidity by hands.
Caution: Do not use the water or oil-based detergent when
clean the unit.
Caution: Do not use the unit where flammable or explosive gas,
direct sunlight, radiant heat, vibration or impact may be present.
Caution: keep dust and wire residue from flowing into the unit.
Ordering Information
Terminal Connection
Power & Output
terminal
V+
Gnd
1
24VDC(±%10)2.4W
+
-
mA DC 4-20 mA
(∆P)
-
+
DP- - - C
V+
Gnd
1
24VDC(±%10)2.4W
+
-V0-10 Vdc
(∆P)
-
+
DP - - - V
DP - - - M
V+
Gnd
1
24VDC
(±%10)
2.4W
-
+
2Master
device
B (+)
A (-)
Slave
device
B (+)
A (-)
Set Measuring rang
Measuring ran is Multi range and can set by 2 Dip switches.
DP- - - C
DP- - - V
Dip switches for
Set measuring rage
Caution During use:
1. Do not store at the high temperature /humidity environment.
2. For cleaning use dry towel and do not use acid ,chrome acid,
solvent but alcohol.
3. Separate the unit cable from high voltage line. power line to avoid
inductive noise.
4.installation environment: it shall be used indoor and pollution degree 2
Failure to follow these instruction may result in product damage.
V+
Gnd
1
2
TH R D1 C
C
V
M
W
Current
Voltage
Mudbus
Wireless
N
D1
D2
D3
No Display
LCD small
LCD large
7seqment
R
D
W
O
Room
Duct
Wall
Outside
TH
DP
MD
CM
Temperature and Humidity
Differential Pressure
Motor Damper
Clean Room Monitor
Output
Signal
Display
Type
Mounting
Type
Product
Type
MP Monitoring Pack Device
Sw1 Pressure Range Time
S1 S2 S3 : On S4
On
On
On On
0...100Pa
0...500Pa
0...1000Pa
0...2000Pa
±100Pa
±500Pa
±1000Pa
±2000Pa
On
1S
5S
Off Off
Off
Off
Off
S3 : Off
ON DIP
1 2 34
Sw1
Yellow LED will On
when power is okey
Model
Power supply 24 VDC ± 10% 2.4W
Output
signal
Resolution 16 Bit
Protection
class IP 65
Cable Ø 0.5mm , 4-Wire
DP- -
D
Measuring
Range
Sensitivity
Pressure ± 0.5 P.a
Specification
Certificate of Calibration
±2000Pa (Multi Range)
DP- - - C===> 4 ~20 mA
- - V===> 0 ~ 10 Vdc
- - M===> Modbus RTU
- - W===> WIFI (Wirless)
- - R===> Relay(Switching)
D
DP- D
DP- D
DP- D
DP- D
B1
B1 (button) for
reset measuring value (Zero)
Modbus communication address
Modbus communication
Comm. protocol Modbus RTU
Comm. type Rs485
Max.connection 255unit(address:01up255)
for use max 31 devices, must use Repeater
Comm. method Two-wire half duplex
Comm. distance Max. 500m
for max 150m, must use Repeater
Comm. speed 9.6 and 19.2kbps(selectable)
Start bit 1-bit (fixed)
Data bit 8-bit (fixed)
Parity bit None (fixed)
Stop bit 1-bit (fixed)
Interface
Master
device
B (+)
A (-)
TH
#1
B (+)
A (-)
TH
#2
B (+)
A (-)
TH
#30
B (+)
A (-)
TH
#31
B (+)
A (-)
Enable
terminating
resistance
Modbus network connection
Modbus Mapping Table
Address Item Remark
40002 (0001)
40003 (0002)
Temperature value
Humidity value
Temperature value x 0.01
Humidity value x 0.01
Modbus communication setting
8 Dip switches for
Set communication address
TH - - - M
ON DIP
1 2 345678
sw1
j1
Enable or Disable
Terminating resistance
ON
1 2
sw2
2 Dip switches for
Set Communication Speed
Sw1 Address
S5 S4 S3 S2 S1
1
0000
0
1000
1
1000
0
0100
1
0100
0
1100
1
1
100
0
00
1
0
1
0010
0
1010
1
1010
0
0110
1
0110
0
1110
1
1110
0
0001
1
0001
0
1001
1
1001
0
0101
1
0101
0
1101
1
1101
0
0011
1
0011
.
.
.
.
.
1
0111
0
1111
1
1111
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
.
253
254
255
S1S6S7S8
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
111
111
111
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
..
.
.
.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Modbus communication speed
Sw2 Baud
rate
9.6 kbps
19.2 kbps
-
-
0
0
1
0
0
1
1
1
S7 S6
Dimensions
Accessories :
AKO Corporation
www.ako-auto.com
Tel&Fax: +98 41 35 59 53 48
Email: [email protected]

Other AKO Transmitter manuals

AKO AKO-575 N Series User manual

AKO

AKO AKO-575 N Series User manual

AKO AKO-575744N User manual

AKO

AKO AKO-575744N User manual

AKO AKO-575022 User manual

AKO

AKO AKO-575022 User manual

Popular Transmitter manuals by other brands

Sennheiser SK 300 instruction manual

Sennheiser

Sennheiser SK 300 instruction manual

WIKA IS-3 operating instructions

WIKA

WIKA IS-3 operating instructions

Labom CK5 Series operating instructions

Labom

Labom CK5 Series operating instructions

Audio A10-TX user guide

Audio

Audio A10-TX user guide

Emerson Bristol 2808 Series instruction manual

Emerson

Emerson Bristol 2808 Series instruction manual

Motorola T505 - MOTOROKR - Speaker Phone instruction manual

Motorola

Motorola T505 - MOTOROKR - Speaker Phone instruction manual

Optelecom-nkf 9172DT Installation and operation manual

Optelecom-nkf

Optelecom-nkf 9172DT Installation and operation manual

Firefly 318ALD33K instruction manual

Firefly

Firefly 318ALD33K instruction manual

NGS SPARK V2 user manual

NGS

NGS SPARK V2 user manual

Honeywell SmartLine ST700 user guide

Honeywell

Honeywell SmartLine ST700 user guide

Nautel NX5 Operation & maintenance manual

Nautel

Nautel NX5 Operation & maintenance manual

Sentera Controls DSMFM-2R Mounting and operating instructions

Sentera Controls

Sentera Controls DSMFM-2R Mounting and operating instructions

F-S Electronics HLLY TVX-02S instructions

F-S Electronics

F-S Electronics HLLY TVX-02S instructions

Blue Sea VSM 422 manual

Blue Sea

Blue Sea VSM 422 manual

Kingspan SENSiT installation manual

Kingspan

Kingspan SENSiT installation manual

Kramer TP-210 user manual

Kramer

Kramer TP-210 user manual

newins NT5400E Series manual

newins

newins NT5400E Series manual

Vaisala DMP248 Configuration

Vaisala

Vaisala DMP248 Configuration

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.