Alcofind DA-8100 User manual

DA-8100DA-8100
DA-8100
Please read the user's manual carefully before use.
Breath Alcohol Tester
Advanced fuel cell sensor
Personal & professional use alcohol tester
Instruction
Manual
Professional Fuel Cell Sensor
High Accuracy & Precision
Reliability & Stability
User adjustable settings
blow time / unit / beep alarm /
flow detecting)
HADRON

Introduction
Thank you for purchasing our product.
Alcofin d DA-8100 is a breathalyzer with a fuel cell sensor.
It offers enhanced accuracy and is easy to carry.
It is suitable for personal use as well as professional use.
It provides linear accuracy with high-reliability.
Name of Each Part
Contents
Digital breathalyzer
Alcofind DA-8100
2 (two) AA size batteries
6 (six) mouthpieces
Carrying case
Hand strap
User's manual
Mouthpiece in
Display window
START button
MODE button
Product Specifications
The specifications are subject to change without prior notice for functional improvements.
Indication of B.A.C.
Accuracy
Warm up time
Response time
Sensor
Power supply
Battery Life
Dimensions(WxHxD)
Weight
Calibration
Operating temperature
0.00 ~ 0.50%BAC
0.00 ~ 5.00
0.00 ~ 2.50mg/l
+/- 0.005%BAC at 0.1%BAC at 25 C
+/- 0.05 at 1.0 at 25 C
+/- 0.025mg/l at 0.50mg/l at 25 C
Within 18 seconds at 0.05%BAC
Within 10 seconds at 0.05%BAC
Fuel cell sensor
2 (two) AA size alkaline batteries
Approx. 1500 tests
52mm x 123mm x 29mm
127g including batteries
every 12 months or after 500 tests
0 ~ 40 C
HADRON

Indication of
test result
Breath sampling
Breath Analyzing
If the user does not blow a sufficient breath
sample, the LCD will display "FLO".
Press "start" to restart the countdown cycle and retest.
If there is no breath sample blown within
30 seconds, the LCD will display "OUT".
Press "start" to restart the countdown cycle and retest.
How To Use
1. Initial Use
2. How to test Breath Alcohol Concentration
Press down the battery cover of theunit to openit and install
two AA size 1.5 V alkalin e batteri es paying attention to the battery polarity.
Close the battery cover and insert the mouthpieceinto the slot.
a) Press the start button and unit willdisplay the total number of tests
performed for a second and will begin acountdown.
b) When the countdown reaches "0" (zero), thenblow into the mouthpiece
for more than 4~5 seconds until there isa double beep sound.
c) Once the sensor has analyzed the breathsample, it will display the
estimated Blood Alcohol Concentration.
(When the unit operates normally)
Error Messages
HADRON

3. How to adjust measurement "unit"
4. How to adjust "beep" (audible warning)
5. How to adjust "blow time"
If the unit is powered on outside of the acceptable temperature
range (0-40 C) the unit will display Out C and the
test cannot be performed.
If the battery indicator display is empty,
install two new alkaline AA batteries.
a) Press the start button and the unit will display the total number of tests
performed for a second and will begin a countdown.
b) During the countdown, press and hold the mode button for more than 5
seconds until the unit displays
If you press the mode button again shortly, the unit displays
c) By pressing the start button, you can adjust the beep level.
a) Press the start button and the unit will display the total number of tests
performed for a second and will begin a countdown.
b) During the countdown, press and hold the mode button for more than 5
seconds until the unit displays
Press mode button shortly until the unit displays
c) By pressing the start button, the blow time can be adjusted.
a) Press the start button and the unit will display the total number of tests
performed for a second and will begin a countdown.
b) During the countdown, press and hold the mode button for more than 5
seconds until the unit displays
c) By pressing the start button, the measurement unit can be adjusted.
HADRON

Flow Detection Settings
6. How to adjust "flow detecting setting"
a) Press the start button and the unit will display the total number of tests
performed for a second and will begin a countdown.
b) During the countdown, press and hold the mode button for more than 5
seconds until the unit displays
Press mode button shortly until the unit displays
c) The flow detecting setting can be adjusted by pressing the start button.
d) Three kinds of settings are available - Low, High, User.
Use this option to adjust how hard a user is required to blow.
Press Start to change the settings.
Low level flow detection
This is the default setting for the unit.
High level flow detection
Press start to change to the high level flow setting.
This level requires a stronger breath by the user and is
recommended if previous test attempts have been unsuccessful.
User activated test mode
Press Start again to change to the USER
activated test mode. When testing in this
mode, the operator must press Start to take a breath
sample during blowing and to perform a test.
HADRON

Warnings
Manufacturer Distributor
Customer Service
For any question, after sales service, product calibrationor purchasing mouthpiece,
please get in contact with the nearest distributorin your country.
Warranty Card
Product
Warranty
Period
Seller
Shop name
Owner name
Digital Breathalyzer Alcofind DA-8100
Purchasing
Date
(DD-MM-YY)
Wait at least 20 minutes after drinking alcohol to test blood alcohol concentration.
For protection of the sensor, avoid direct sunlight, extreme temperature, humid
places. Keep the device in a well ventilated place and keep out of reach of children.
When not used for a long time, store the device without the batteries.
The test results can be inaccurate for about first three tests after a long-term storage.
Reuse after a long-term storage, there might be high tolerance of test
result for about first 3 tests.
We recommend you to replace the disposable mouthpiece for sanitary purpose.
Do NOT use the device as a tool to determine "drink and drive".
The manufacturer and seller will not take any legal responsibility for the measured test value.
Shocking during the test might cause wrong test result.
When the battery icon is flickering, then use new batteries for the precise test.
If test result shows 0.1%BAC or higher, then warm up time might be delayed.
Test under loud noise could be the reason of malfunction. In thiscase, try again in a quiet place.
If you perform testing at 10 C or below, the test result might be inaccurate.
In case some amount of moisture and/or saliva enters into the breathalyzer, it might
cause malfunction of the device. In this case please wait at least 1~2 hours before using,
until the moisture and/or saliva dried up.
For any defects due to natural disaster orcustomer's negligence,
misuse, reconstruction and repair by unauthorized person,
reasonable cost shall be charged for repair orpart replacement.
The manufacturer warrants the product to be freefrom defects in
workmanship or material (excluding calibration) under normal useeither
for 1(one) year from date of purchase.
The manufacturer's obligation under this warranty is limitedto replacing,
adjusting or repairing the unit at manufacturer's option,if returned along
with proof of purchase.
HADRON
Table of contents
Other Alcofind Test Equipment manuals

Alcofind
Alcofind AF-50 User manual

Alcofind
Alcofind DA-7000 User manual

Alcofind
Alcofind da-8000 User manual

Alcofind
Alcofind DA-7100 User manual

Alcofind
Alcofind DA-5000 User manual

Alcofind
Alcofind DA-9000 series Use and care manual

Alcofind
Alcofind AF-100S User manual

Alcofind
Alcofind AF-50 AD User manual

Alcofind
Alcofind AFM-5 User manual