IMPORTANT INFORMATION
If you do not follow the instructions for use your test results may be
inaccurate and your warranty may become void.
For most accurate results, it’s important to wait at least 20 minutes after smoking, eating or drink-
ing before testing. This is a universal principle for all breathalysers, not just yours. The reason being
is that if you have recently consumed alcohol, the residual alcohol in your mouth is very high and
can cause a false reading. Additionally, waiting 20 minutes allows the alcohol to be absorbed from
your stomach into your bloodstream, contributing to more accurate test results.
DEFENDER®
AlcoLimit®
pg-3
PARTS OF YOUR BREATHALYSER
AlcoLimit’s Flow Control Technology checks the ow rate of your breath. An
adequate air sample must be received before it will provide you with a reading.
This is just one of the safety measures built into the AlcoLimit range.
AlcoLimit’s Intelli-sensor Recognition Technology checks the sensor condition
every time you use your breathalyser. Stability of the sensor is analysed and an
indication will be given if the sensor needs recalibration.

pg-4
SPECIFICATIONS
Recommended Usage Personal
Sensor Type Electrochemical Fuel Cell
Accuracy Conforms to Australian Standard AS3547
Range %BAC 0.000 - 0.400
Display 3 decimal places with Backlight
Warm-up time < 35 seconds
Breath Sampling Time 6 seconds (approx.) a minimum ow
must be received to get a reading
Housing Shock Resistant Plastic
Weight 84 grams (with batteries)
Power Source 2 x 1.5V 'AAA' batteries
Dimensions 114mm x 47mm x 24mm
Warranty 12 Month Limited Warranty
Recalibration Period 500 uses or 1 month, whichever comes
rst
Mouthpieces Disposable - 3 included
Specications are subject to change for the purpose of product improvement.
For all after-sales service and enquiries please contact the manufacturer:
AlcoLimit Breathalysers Pty. Ltd.
P.O. Box 1106
Manly, N.S.W. 1655
Australia
Ph: 1300 667 661 or +612 9939 3077 (from overseas)
Website: www.alcolimit.com.au
DEFENDER®
AlcoLimit®

pg-4 pg-5
DEFENDER®
AlcoLimit®
USAGE
First, place 2xAAA batteries (supplied) into your ALCOLIMIT DEFENDER.
Slide the rear tab across to release the
battery compartment cover and slide it
downwards to remove.
Ensure the batteries are inserted in
the correct direction.
1. To turn your ALCOLIMIT DEFENDER on, depress the ON/OFF button for 2 seconds until
the screen turns on.
2. The unit will commence a warm-up process.
Purge cycles and circuit tests are taking place during this time. This process generally takes 30
seconds but can last 2 minutes.
3. The unit is ready when two beeps sound and the word bLo will appear on the display.
If you don’t blow into the breathalyser within 20 seconds it will turn off.
4. Attach the mouthpiece tube and blow one consistent deep breath into the
sensor. There will be a beeping noise while you are blowing.
A full lung of air is required. Once your ALCOLIMIT DEFENDER has received enough air-
flow you will hear a double click signalling you to stop.
If inadequate airflow is received, the word FLo will appear on the screen. Do not block the air
hole on the opposite side of the mouthpiece while testing as this will affect the airflow.
5. A circling line will appear on the display while the breathalyser is analysing your breath
sample. Your %BAC result will then be displayed on the screen.
The display shows only 3 digits to the right of the decimal place.
For example ‘050’ indicates ‘0.050%BAC

pg-6
DEFENDER®
AlcoLimit®
Breath Alcohol
Concentration (BAC)
Digital Display and Audio Signals
0.000-0.049% %BAC displayed on screen with audible beep and Green LED
light
0.050 - 0.400% %BAC displayed on screen with one long audible beep and
Red ‘WARN’ LED light
0.400 upwards ‘HOT’ will appear on the screen indicating the maximum level
has been reached
RETESTING
Press the ON/OFF button as soon as the Red or Green LED light turns o. The breathalyser
will then start the countdown for the next test.
To retest, if your AlcoLimit DEFENDER has turned itself o, depress the on/o button, and
wait for it to warm up again.
When high alcohol readings are received, retesting should be spaced 3 minutes apart to
allow all alcohol vapour to be eliminated from the sensor.
DISPLAY & INTERPRETATION
Your %BAC will be displayed on the screen for 20 seconds after which your ALCOLIMIT
DEFENDER will turn itself o.
This device is a 0.05% BAC device (0.05%BAC is equal to 0.05grams of alcohol per 100ml of
blood).
Australian & New Zealand Customers: The drink driving cut-o for people on a full licence
is 50mg per 100ml of blood. This equates to 0.05%BAC.
This is current as at April 2015. The Australian & NZ Govts. may change this level in the future
so please check before driving.
PLEASE NOTE: Alcohol vapour on your breath will cause a higher reading. We recommend
having a glass of water prior to testing and waiting at least 20 minutes after your last drink
for accurate results. Not waiting the required 20 minutes will saturate the sensor unneces-
sarily and may cause sensor damage. This is not covered under your warranty.
Please always wait 20 minutes after consuming any alcohol to avoid this problem.

pg-6 pg-7
DEFENDER®
AlcoLimit®
TROUBLESHOOTING GUIDE
Display Explanation
The result is higher than 0.050%BAC.
An alarm sounds and WARN light is on.
The result is higher than 0.400%BAC.
An alarm sounds and WARN light is on.
There is not enough voltage in the batteries.
The yellow BATT LOW light is on.
Replace with 2 x AAA alkaline batteries.
The sensor has not detected a long enough or strong
enough breath.
Press the ON/OFF switch again and retest. Ensure a strong
consistent breath is provided until the click sounds.
Calibration is due.
The unit may no longer provide accurate readings.
Red WARN light is on.
See ‘Recalibration’ page for details.
The ambient temperature is outside the recommended
Working Temperature range of 5-40°C.
The red WARN light is on.
For any other issues please call our customer centre on
1300 667 661 or +612 9939 3077 (NZ customers).

pg-8
DEFENDER®
AlcoLimit®
WARNINGS (Please read carefully)
• Closedroomswithpoorventilation,pollution,smokeorairconditioningmaydelaythetimefor
resetting between tests.
• Avoidtestinginthepresenceofanysubstancesthatcontainmethylalcohol,isopropylalcohol
or acetone. These substances may interfere with the results of the test.
• Notwaitingatleast20minutesafteryourlastalcoholicdrinkwillcauseinaccuratereadings,and
if you continue to misuse ALCOLIMIT this way you will damage the sensor beyond repair (not
covered under warranty). Have a glass of water or other non-alcoholic beverage to minimise
alcohol vapour in your mouth as the vapour can cause a higher reading.
• Retest2-3timestoobtainareliabletestresult.Wesuggestyouthenwaitafurther10-20
minutes and retest to check that your level has stabilised and not increased.
• Bloodalcoholconcentrationcancontinuetoriseforupto2hoursafterthecessationof
drinking. If the reading is close to the limit it is advised to wait a further 10-20 minutes and re
test to determine whether your %BAC has stabilised.
• Itcantake10hoursormoretoreturntoazeroreadingafterahighbloodalcohollevelhasbeen
reached. A further test should be carried out later in the day or the following morning.
• IfyouaretakingALCOLIMIToverseasorusingitatadierentaltitudepleasebeawarethatthe
calibration may be aected.
• Donotblowcigarettesmokeorliquidintothetester.
• Alcoholaectseachindividualdierentlydependinguponmanyfactors;typeofalcohol,
muscle mass, weight, full or empty stomach, immune system, gender, regularity of drinking.
• Thosewithdiabetesmayndtheycandrinklargevolumesofalcoholyetstillread0.00%BAC.
This does not mean your ability to drive is not impaired.
• DonotuseALCOLIMITasatooltodrinkanddrive.Thereisnosafelevelofalcoholconsumption
before driving or operating machinery.
• TheonlytrueindicationofyourBloodAlcoholConcentration(BAC)isabloodtest.Theresults
obtained from a personal breath alcohol tester cannot be used in a court of law.
STORAGE CONDITIONS
Keep free from dust, dirt, and small particles as they may clog the sensor.
Keep in a cool dry place.
Keep out of extreme temperatures.
Keep out of reach of children.
Keep away from electrical interference.
Do not drop, knock or shake.

pg-8 pg-9
DEFENDER®
AlcoLimit®
RECALIBRATION
The calibration period of ALCOLIMIT DEFENDER is 1 month or 500 uses, whichever comes rst.
A specially calibrated alcohol simulator is used to recalibrate the ALCOLIMIT DEFENDER and the
electronics need to be reset during recalibration, do not attempt to service it yourself.
If you receive erratic or high readings your breathalyser may need recalibration.
If you have any doubt about the readings you are receiving from your ALCOLIMIT DEFENDER then your
breathalyser may need recalibration.
Periodic recalibration is required because over time breath alcohol testing devices may drift from their
calibration setting even when not used.
Your ALCOLIMIT DEFENDER is a sensitive instrument. Unlike other electronic devices, your breathalyser
shouldn’t be ignored for long periods of time. The sensor inside it is delicate and can dry out if left un-
used for too long. In order to keep it in good working condition, we recommend that you blow into it at
least once a month, even if you don’t plan on using it. Breathing into the unit regularly keeps the sensor
moist and in good working order. Sensors that dry out can sometimes require more frequent calibration.
Professional Calibration by our Technicians:
Recalibration costs $45 AUD and includes return postage to you within Australia and NZ via Australia
Post.
Post your ALCOLIMIT unit to :
AlcoLimit Breathalysers Pty. Ltd.
Recalibration Dept.
P.O. Box 1106
Manly, N.S.W. 1655
When posting your ALCOLIMIT DEFENDER to us you are advised to send it Registered Mail for tracking
purposes.
You must include the following:
- your name
- return postal address
- daytime phone no.
- payment
- instruction manual to update service record
If you require a‘Calibration Certicate’please request one at the time of recalibration. These cost $22
each (incl. GST)

pg-10
DEFENDER®
AlcoLimit®
You may pay with credit card online via PAYPAL on our ‘SERVICING’ page at:
www.alcolimit.com.au/servicing
Or you may call us on 1300 667 661 to pay with credit card.
Payment can be made via money order made out to:
‘AlcoLimit Breathalysers Pty. Ltd.’
Your unit will usually be returned to you within a week. If you have any questions regarding
recalibration, please call us on 1300 667 661 or +612 9939 3077
For NZ Customers we recommend payment via Credit Card due to exchange rate changes.
WARRANTY
Manufacturer warrants for one calendar year the product to be free from defects in workmanship or
materials (excluding calibration) in normal service from the date of purchase. Manufacturer’s obligation
under this warranty is limited to replacing or repairing the unit if returned along with proof of purchase.
This warranty is void if unit has been tampered with, misused, dropped, maliciously damaged or used for
any purpose other than that intended.
The cost to return the unit to the manufacturer’s service centre is at the expense of the consumer. The
consumer is welcome to drop the unit o at our service centre in person. The consumer must contact our
customer service centre prior to returning the unit to us to enable our technicians to diagnose the fault
over the phone.
Upon returning the unit to our service centre under warranty, should the unit be found not to be faulty,
the consumer is liable for the freight cost to return the item to them. Should the unit be found to be
faulty the freight cost to return the item to the consumer will be borne by the manufacturer.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are
entitled to a replacement or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail
to be of acceptable quality and the failure does not amount to a major failure.

pg-10 pg-11
DEFENDER®
AlcoLimit®
DISCLAIMER
AlcoLimit DEFENDER is recommended as a screening device only. The reading you receive is not legally
binding in a court of law, ALCOLIMIT DEFENDER is to be used only as a guide. The only true indication of
your %BAC is a blood test.
Probationary drivers and machinery operators should check with their state authority or employer as
towhethera0.02%BACorzerotoleranceappliestothem.Wedonotrecommenddrivingoroperating
machinery with any amount of alcohol in your system. Heavy nes and penalties may apply and the
presence of alcohol in your system may void your insurance.
The manufacturer gives no warranty, express or implied, as to the ability of ALCOLIMIT DEFENDER to
determine or detect intoxication or to accurately indicate your blood alcohol level. The manufacturer
assumes no responsibility in circumstances where a person who has used the device and received an
indication of the presence of alcohol in his/her exhaled breath is later found to be under the inuence
ofortheirjudgmenthasbeenimpairedbyalcohol;andwillinnocircumstancesbeliableforanylossor
damage in contract or tort (including negligence) or otherwise suered by any person arising directly or
indirectly from the use of ALCOLIMIT DEFENDER.
The manufacturer, importer or distributor takes no responsibility whatsoever for the use of this product
for any reason. This product must not be used as a tool for determining whether a person is able to oper-
ate a vehicle or machinery. The intake of any alcohol will impair reexes and judgment to operate motor
vehicles and machinery.
For further information on ALCOLIMIT DEFENDER, and to view other models available, see our website:
www.alcolimit.com.au or call our information line on 1300 667 661.

pg-12
DEFENDER®
AlcoLimit®
RECALIBRATION SERVICE RECORD
Date of
Recalibration Service Details Technician
For service records to be updated, please send your instructions with your
breathalyser each time it is recalibrated.
Alternatively, you may request a Calibration Certicate at a cost of $22 (recommended for workplaces).
Table of contents
Other AlcoLimit Test Equipment manuals
Popular Test Equipment manuals by other brands

Redtech
Redtech TRAILERteck T05 user manual

Venmar
Venmar AVS Constructo 1.0 HRV user guide

Test Instrument Solutions
Test Instrument Solutions SafetyPAT operating manual

Hanna Instruments
Hanna Instruments HI 38078 instruction manual

Kistler
Kistler 5495C Series instruction manual

Waygate Technologies
Waygate Technologies DM5E Basic quick start guide

StoneL
StoneL DeviceNet CK464002A manual

Seica
Seica RAPID 220 Site preparation guide

Kingfisher
Kingfisher KI7400 Series Training manual

Kurth Electronic
Kurth Electronic CCTS-03 operating manual

SMART
SMART KANAAD SBT XTREME 3G Series user manual

Agilent Technologies
Agilent Technologies BERT Serial Getting started