Alen A375UV Uktra User manual

1
www.AlenCorp.com 1-800-630-2396
USER MANUAL
A375 UV Air Purifier

2Helping People Live Better

3
www.AlenCorp.com 1-800-630-2396
TABLE OF CONTENTS
Air Purifier Safety
Using Your Air Purifier
Operating Your Unit
Identication Of Parts
Know Your Air Purifier
Care & Maintenance
Replacing e Filter
Why You Should Replace Your Filter
Alen Replacement Filter Auto Ship Plans
How To Replace e Filter
How To Replace e UV Light
Troubleshooting Tips
Lifetime Limited Warranty
4
5
8
8
11
12

4Helping People Live Better
AIR PURIFIER SAFETY
Provided in this manual are important safety messages regarding your electrical home appli-
ance. Always read, follow and save all safety directions.
Location Requirements
• Use a level surface at least 6” (15.2cm) from heat sources such as ranges or heaters.
• Do not block air vent openings or place air purier on a soft surface such as a bed or sofa.
• Never insert ngers or foreign objects into air grills or vents.
• Operate indoors only.
• Electrical and Safety Requirements — Reduce your risk of re or electrical shock.
Failure to follow these instructions can result in death, re or electrical shock.
• Do not connect unit to any electrical socket that is damaged.
• Ensure lter is correctly installed before turning on unit.
• Always turn o the air purier when not in use and before unplugging.
• Do not use next to a source of heat, such as a ranger, heater or dryer.
• Do not use near a bath, shower, swimming pool or where a unit can get wet.
• Change your lter on a regular basis, so dust and particles do not build up.
• Do not plug the air purier into an outlet controlled by a dimmer switch.
• Do not use in a window.
• Unplug air purier before servicing.
• Do not use an adapter.
• Do not use an extension cord.
• Always unplug the unit before changing the lter.
• Do not cover the unit or impede air ow.
• Do not exceed the rating of the power outlet or connection device. May cause electric
shock or re due to excess heat generation.
• Do not insert or pull out plug with wet hands, it may cause electric shock.
• Never try to take apart or repair the unit by yourself.
• Disconnect the power if strange sounds, smell or smoke comes from it.
• Do not try to change the lter during operation.
• Do not drop the unit, as this can result in damage.
• Do not place heavy objects on the power cord and take care so that the cord is not com-
pressed as there is danger of re or electric shock.
• Do not climb up or sit on the unit. You may be injured if you fall or if the unit falls over.
• Do not spray insecticides or any other ammable sprays near the machine. It may cause
explosion or re.
• Use only in the proper electrical socket type. Socket type (voltage & hertz) can be found
on the product sticker on the side or bottom of the unit. Plugging the unit in to the
incorrect socket type can damage/destroy the unit.
• To reduce the risk of electric shock, this equipment has a polarized plug (one blade is
wider than the other). is plug will t in a polarized outlet only one way. If the plug
does not t fully in the outlet, reverse the plug. If it still does not t, contact qualied
personnel to install the proper outlet. Do not alter the plug in any way.

5
www.AlenCorp.com 1-800-630-2396
USING YOUR AIR PURIFIER
Operating Your Unit:
1. Plug your air purier into a grounded outlet.
2. Press ON/OFF to start the air purier. When your unit is on the control panel screen
will light up. To stop the air purier press ON/OFF and the indicator light will turn o.
3. Press SPEED and watch the indicator numbers until desired fan speed is achieved.
4. Press TIMER to have the air purier automatically turn o in a set amount of hours.
Up to eight hours.
5. Press IONIZER to activate the ozone safe built in ionizer. Activation of IONIZER en-
hances your unit’s ability to remove airborne particles (similar to the way dust is attracted
to a TV screen) and keep the air fresh. Press IONIZER again to turn o.
6. Filter replacement indicator — Light bar will progressively illuminate as lter collects
particles. ere are two green, two yellow and one red bar. Each bar represents approxi-
mately one month of continuous operation. Once all ve bars are fully illuminated (red
being the last), it is time to change the lter.
7. After changing the lter, RESET the lter indicator by holding down TIMER while the
unit is ON until the clean indicator light disappears.
8. Press UV to activate the built-in ultraviolet lights. Press UV again to turn o.
9. When on AUTO fan speed, the unit will adjust fan speed based on the level of dust or
smell. Dust and smell bars adjust horizontally as their respective levels change.
Fan Speed Result
Level 1 Quietest operation
Level 2 Basic cleaning power
Level 3 Moderate cleaning power
Level 4 Maximum cleaning power
Auto AUTO fan speed, the unit will adjust fan speed based
on the level of dust or smell. Auto begins on level 1
and if triggered will clean at level 4.

6Helping People Live Better
Identification Of Parts
Puried air outlet grill
Front air intake
grill
Side air intake
Dust and smell sensors Control panel
5. Ozone safe optional Ionizer.
Press to turn Ionizer ON or OFF.
4. Eight hour timer. Press to display
desired hours in which to shut
o unit.
2. Press to START or STOP
your air purier.
9. Dust and smell bars adjust
horizontally as their levels change.
6. Noties you when it’s time
to replace the lter.
7. Hold down TIMER after
the lter has been changed.
8. Press to turn UV Lights ON
or OFF.
3. Press to select one of four fan
speeds. e illuminated screen
will display selected speed.
Rating label
Wall mountable hooks
(Hardware not included)
Handle for
easy carrying

7
www.AlenCorp.com 1-800-630-2396
ON/OFF
Press this key to start operation,
press it again to stop it.
TIMER
Set the operation time. When
pressing the key, the timer
scale on the panel will
indicate the set time:
Low Medium High
Quiet AutoRun
1 Hour 2 Hour 4 Hour
Cancel 8 Hour
Preset On Time Preset Off Time
Preset Operation Fan Speed
SET UP
Used to set the 3 modes. On
Time, O Time and Air Flow
in operation. When pressed
each time, it will follow the
order below:
Low Medium High
Quiet AutoRun
1 Hour 2 Hour 4 Hour
Cancel 8 Hour
Preset On Time Preset Off Time
Preset Operation Fan Speed
FAN SPEED
Every time you press it, the
fan speed will vary according
to the following order:
Low Medium High
Quiet AutoRun
1 Hour 2 Hour 4 Hour
Cancel 8 Hour
Preset On Time Preset Off Time
Preset Operation Fan Speed
UV
Press this key to start UV,
press it again to stop it.
IONIZER
Press this key to turn on
the ionizer, press it again to
stop it.
INCREASE
An auxillary key of the set
up key, used to increase
operation time and fan
speed. Each time it is
pressed, the present time
will increase by 30 minutes
or the fan speed will in-
crease to the next level.
DECREASE
An auxillary key of the set
up key, used to increase
operation time and fan
speed. Each time it is
pressed, the present time
will decrease by 30 minutes
or the fan speed will
decrease to the next level.

8Helping People Live Better
KNOW YOUR AIR PURIFIER
When using the air purier for the rst time in a room, many prefer to use a higher fan speed
like speed three or four for a couple of hours in order to clean the room’s air initially.
Features
• Photo-Catalytic Oxidation technology. is technology is incorporated with a perma-
nent titanium lter that doesn’t need to be replaced.
• Smell and dust sensors. When the fan speed is set to AUTO, these sensors increase or
decrease the unit’s speed based on the level of odor or dust in the air.
• All in one lter: washable pre-lter with an active layer of carbon and our signature
ltration.
• Eight hour timer.
• Remote control.
• Built-in ultraviolet lights (two) can be manually turned on or o.
• Built-in ozone safe ionizer can be manually turned on or o.
• Filter replacement indicator.
• Digital display with simple and intuitive touch button controls.
• Warranty: Lifetime limited warranty, see page 12.
• Wall-mountable to save space or can be placed on the oor.
CARE & MAINTENANCE
Replacing The Filter
e lters used in all of Alen air puriers are not designed to be washed, cleaned or other-
wise reused. Please replace lter regularly to maintain optimal high performance. Failure to
change your lter on a regular basis will cause dust and particles to build up which can cause
the unit to fail.
e black foam layer of the lter, known as the pre-lter, captures large dust and hair. is
layer is held on with Velcro®. Once removed, the pre-lter can be washed or vacuumed to
maintain ecient operation of the unit.
For optimal performance, it is recommended that the air purier is left on to run continuous-
ly. Under this type of usage, lters will need to be replaced approximately every six months.
Why You Should Replace Your Filter
• Fullls the terms of Alen’s warranty which states that the lters are required to be
changed on a regular basis in order to prevent excessive stress on the unit.
• Energy eciency — Dirty lters make your unit work harder, increasing energy usage.
Replacing your lters on a regular basis increases the performance of your air purier
and reduces your energy consumption.
• You have bought an air purier in order improve the quality of your indoor air. Chang-
ing your lters will maintain the level of air quality you require. Excessively dirty lters
can compromise the level of clean air your air purier can lter.

9
www.AlenCorp.com 1-800-630-2396
Alen Replacement Filter Auto-Ship Plans — Pay Less For More Convenience
Regular replacement of your lter will extend the life of your air purier and keep your air
pure. Alen lters provide ecient ltration for 4 months of heavy usage, 6 months of normal
usage and 8 months of moderate usage. With Alen’s convenient Auto Ship plan your lters
will be shipped for FREE right to your door, exactly when needed.
SAVE — Get FREE LIFETIME SHIPPING on all Auto Ship lters.
CONVENIENCE — Your lters are delivered right to your door exactly when needed.
Choose a 4, 6 or 8 month plan and cancel at anytime.
LIFETIME LIMITED WARRANTY — An Alen Auto Ship plan is the convenient way to
extend the life of your air purier and benet from the lifetime limited warranty.
To sign up and save just visit AlenCorp.com/lters or call 1-800-630-2396.
How To Replace The Filter
Maintenance notes:
1. Always unplug the unit when installing a lter.
2. Distinguish the front side from the back side of the lter.
3. It is recommended to wear gloves while discarding the used lter. Place the used lter in
a plastic bag to prevent dust from reentering the air.
1. With the front of the unit
facing up, pull up on the
lower left or right corner of
the front inlet air intake grill.
2. After pulling up, push the
grill towards the display panel
at the top of the unit.

10 Helping People Live Better
4. Take the new lter out of
the plastic bag and insert
it into the air cleaner with
the arrow pointing inward.
5. Insert the top of the inlet
grill rst and then snap in
the lower part of the grill.
3. Remove the used lter by
lifting the pull string.
6. RESET the lter indicator
by holding down TIMER
while the unit is ON until
the clean indicator light
disappears.

11
www.AlenCorp.com 1-800-630-2396
How To Replace The UV Light
1. Before replacing the UV light, please unplug the unit.
2. With the front of the unit facing up, pull up the lower end of the inlet grill and push it
toward the display panel at the top of the unit, then remove it.
3. Remove the lter by lifting the pull string.
4. Unscrew the screws on the lampshade with a screwdriver, and then remove the lamp-
shade.
5. Gently rotate the bulb a quarter turn in either direction until it unlocks from the socket.
Pull the pins out of the sides of the socket, one end at a time.
6. Unpack the new UV bulb gently by handling the ends only. Starting with one end of
the bulb, then the other, gently insert the metal pins on the bulb into the white slotted
socket one pin at a time. Once the ends of the bulb are completely inserted into the
socket, rotate the bulb a quarter turn until it locks into place.
7. Reinstall the lampshade.
8. Reinsert the lter.
9. Hook the fasteners on the intake grid into the holes on the unit rst, and then push
down on the two sides of the inlet grid until the cover snaps into place.
TROUBLESHOOTING TIPS
How do I reset the filter indicator light? I put in a new filter but the light is still
illuminated.
After changing the lter, RESET the lter indicator by holding down TIMER while the
unit is ON until the illuminated clean indicator light disappears.
Can I clean the filter?
e black foam layer of the lter, known as the pre-lter, captures large dust and hair. is
layer is held on with Velcro®. Once removed, the pre-lter can be washed or vacuumed to
maintain ecient operation of the unit. No other layers or parts of the lter can be washed,
cleaned or otherwise reused. Please replace the lter regularly to maintain optimal high
performance.
How can I tell if my UV lights have burnt out?
Turn on the UV lights by pressing UV and set the fan speed to 1. Make sure the room that
the unit is placed in is dark. Look through the top of the unit where the air blows out to see
if there is a blue glow. is glow is quite faint, so you may need to press the UV button on/

12 Helping People Live Better
o several times to see if you notice a dierence. If there is no glow, then the UV lights have
burnt out and need to be replaced. Visit www.AlenCorp.com or call 1-800-630-2396 to or-
der a replacement UV light. UV lights are like normal light bulbs and will last approximately
9 to 12 months when operated continuously.
Will the photocataylic oxidation filter work if the UV lights are turned off?
No. e interaction of UV-C light and a permanent titanium dioxide (TiO2) grid serves
as a photo catalyst to carry out hydrolysis (i.e. to break water into hydrogen and oxygen).
As TiO2 is exposed to UV light, it becomes increasingly hydrophilic. us, it can be used
reduce concentrations of airborne pollutants such as volatile organic compounds (VOCs)
into harmless elements.
Do I need to replace the photocatalytic oxidation filter?
No. is lter is permanent and does not need to be replaced. However, the UV lights will
need to be replaced as needed.
I have an issue not listed in this manual.
Please visit www.AlenCorp.com and send us a message or call 1-800-630-2396. A customer
service representative will respond to your inquiry in a timely manner, in most cases within a
couple of hours.
What information do I need when I contact customer service for warranty?
Please refer to the rating label on the side of the unit. is rating label has your unit’s lot
code and other important information we need to assist you.
LIFETIME LIMITED WARRANTY
What Is Covered?
Alen oers the industry’s rst LIFETIME LIMITED WARRANTY program for all our air
puriers. We warrant your Alen air purier to be free from defects in materials or workman-
ship for as long as you own it.
What Will Alen Do?
Alen will, at its option, either furnish a replacement part or replace your air purier provided
the product is determined by Alen to be defective as a result of faulty material or workman-
ship while in normal use. Replacement parts or units will, at Alen’s option, be either new or
refurbished. Alen’s sole obligation under this warranty is to replace defective parts or replace
your air purier free of charge.
How To Get Service?
is warranty will be valid only for units in possession of the original purchaser. Proof of
purchase must be presented to Alen’s warranty service representative. All parts or units that
are replaced become the property of Alen. To obtain warranty service, the defective product
or part must be shipped or delivered to Alen’s authorized service center. All postage, insur-
ance and shipping charges by you to Alen and from Alen to you are the responsibility of the
purchaser and are not included in this warranty. Call 1-800-630-2396 for warranty claim
shipping address.

13
www.AlenCorp.com 1-800-630-2396
Your Lifetime Limited Warranty Program Remains In Effect Only If:
Your Alen air purier is operated in accordance with the instructions provided in the Alen
user manual. is includes replacing the lter at least once every six (6) months of use to
prevent excessive stress on the motor. While you can purchase replacement lters through
any authorized dealer, if you are enrolled in any of Alen’s replacement lter Auto Ship plans
you are considered in compliance with the foregoing requirement. Visit http://www.alencorp.
com/lters or call 1-800-630-2396 to enroll in Auto Ship.
• Your Alen air purier is connected to a proper power supply (see voltage label on unit).
• e unit shows no evidence of tampering, mishandling, neglect, accidental damage,
modication, and/or repair by anyone other than authorized Alen service personnel.
• Ownership of the air purier has never been transferred.
DISCLAIMERS/LIMITATIONS
ALEN’S LIFETIME LIMITED WARRANTY IS VALID ONLY FOR THE ORIGINAL
PURCHASER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU-
LAR USE OR PURPOSE. ALEN’S SOLE LIABILITY WITH RESPECT TO DEFECTS IN
MATERIALS AND WORKMANSHIP IN THE AIR PURIFIER SHALL BE, AT ALEN’S
OPTION, TO FURNISH REPLACEMENT(S) OF THE DEFECTIVE PART(S) OR REPLACE
THE AIR PURIFIER ON THE BASIS DESCRIBED ABOVE. ALEN WILL NOT INSTALL
ANY REPLACEMENT PARTS IT PROVIDES OR PROVIDE LABOR WITH RESPECT TO
THE SAME. EXCEPT AS STATED IN THE IMMEDIATELY PRECEDING SENTENCE,
ALEN SHALL HAVE NO LIABILITY, WHETHER UNDER A CAUSE OF ACTION IN
TORT, STRICT LIABILITY, CONTRACT, OR OTHERWISE, TO ANY PERSON FOR ANY
CLAIM, INJURY, LOSS, DAMAGE OR EXPENSE (INCLUDING ANY DIRECT, INDIRECT,
SPECIAL, CONSEQUENTIAL, INCIDENTAL, PUNITIVE OR EXEMPLARY DAMAGES)
IN ANY WAY ARISING OUT OF OR RELATING TO THE AIR PURIFIER OR ITS USE BY
ANY PERSON.
SOME STATES DO NOT ALLOW LIMITATIONS ON AN IMPLIED WARRANTY OR
HOW LONG AN IMPLIED WARRANTY LASTS, SO ANY SUCH LIMITATION IN ALEN’S
LIFETIME WARRANTY MAY NOT APPLY TO YOU. SOME STATES DO NOT ALLOW
THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL OR
OTHER DAMAGES SO ANY SUCH EXCLUSIONS OR LIMITATIONS IN ALEN’S LIFETI-
IME WARRANTY MAY NOT APPLY TO YOU. ALEN’S LIFETIME LIMITED WARRANTY
GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS
WHICH VARY FROM STATE TO STATE.

14 Helping People Live Better
Copyright © 2011 Alen Corp. All Rights Reserved.
a375uv-pm-3-2011
Other manuals for A375UV Uktra
1
Table of contents
Other Alen Air Cleaner manuals