AlkaWay Ultrastream Undersink Kit User manual

Undersink Installation
®

Features
• Quick Connect attachments for simple installation.
• Ceramic faucet valves.
• Vented faucet design.
Congratulations on choosing the AlkaWay Undersink Kit for
yourUltraStreamwaterltersystem.
Follow the steps in the manual and you’ll have clean, pure
lteredalkalinewaterandanunclutteredbenchtop.
WehavedesignedourUndersinkKittobefullycompatible
with the UltraStream Benchtop unit.
For videos, help and support go to www.alkaway.com.au/support
Scan code for
installation video
2
Quick Connect Tips
collet
Familiarize yourself with ‘Quick Connect’
connection. These are special patented
connection tools that allow ultra-simple
connectionoftubes.Toattachatube,allyou
needtodoispushthetubeintothetting.
To remove, all you need do is push on the collet
(ring)aroundthetubeusingtheQuickConnect
Spanner(oryourngernails),thenpullonthe
tubetoremoveit.
It’simportanttoensuretheendofthetubeiscut
cleanly and at right angles.

We strongly encourage you to read the manual carefully and
keep a copy of this manual for future reference.
AlkaWay is not liable nor responsible for any damage resulting from user
installation contrary to instructions in this manual.
Important Information
Molecular Hydrogen Production ‘The Drip’
Your UltraStream may initially drip or spurt for short time after install. This is the
resultofthemolecularhydrogenbeingcreatedbyourspecialO-Dobialkalizingmediaas
it reacts with water in your UltraStream. This is part of the normal settling in process.
If you decide that you cannot handle the initial dripping before installing the
UltraStream, you can return your unused unit. (Only valid within 30 days of purchase.
Must be in new condition).
The UltraStream Filter Life
WetestedtheUltraStreaminauniversitylaboratoryupto3600litres(950gallons).Under
typical municipal water quality standards, this is more than enough for a family of four
whoeachconsume2litresperday.Weadvisechangingthelterafter3,000litres(or800
gallons)or12months,whichevercomesrst.
Warranty
A3-YearwarrantyisprovidedbyAlkaWayAustralia.
Wecannotguarantee12monthsor3000litres(800gallons)lterlife.Allwaterltersare
dependent upon the quality of your source water and will fail if excessive contaminants
andsedimententerthelter(Unlessthereisamanufacturerdefect).
When installing your UltraStream, please remain in compliance with this manual to
maintain your warranty.
You must use a vented faucet for all undersink installations. Failure to do so will void
your warranty.
This warranty does not apply to any commercial or industrial installations or to any part of
thewaterconditionerwhichhasbeensubjectedtomisuse,neglect,alterationoraccident;
ortoanydamagecausedbyre,ood,freezing,ActsofGod,oranyothercasualty.
Safety Tips
DonotrunhotwaterthroughyourUltraStream.
UltraStreamisnotdesignedforusebyyoungchildrenwithoutresponsibleadult
supervision.
UltraStream is constructed of EPA approved BPA-free plastics. All media and materials
used are US and EU approved.
Detox Effects
Some new drinkers to UltraStream water may experience a range of detox like symptoms.
Mostcommonarebodyaches,headaches,fogginessorskinconditions.Ifsymptoms
persist contact your medical practitioner as drinking UltraStream water is perfectly safe
and should have no long term adverse effects.
Onceyoubecomearegulardrinkeryoumayexperienceawiderangeofpositiveeffects.
Youwillndfellowusers’storiesonourwebsiteandwe’dlovetohearyours!Emailusat
info@alkaway.com.au with yours.
3

Undersink Kit Contents
Size
Converter
Quick
Connect
Spanner
What you will need (other than what’s in this kit)
• ElectricDrill.
• MetalHoleSaw-30mm-32mmforstainlesssteelsinks.
Forstonebencheswerecommendcontactinganexpert.
• Masking Tape.
• Rasp, Metal File or Sand Paper.
• Ajustablespanner
Faucet Nut
(Comes on faucet)
Vented Faucet
PLV
(Pressure
Limiting Valve)
Cold Water Connector
(Angle Stop Valve)
Black Washer
(Comes on faucet)
3x 1/4” Plastic Tubes
(1.2 meters each)
4
Metal Inlet Tubes
(3lengths:short,mediumandlong)

1. Cold Water Connection
2. Vented Faucet Hole
1. Cut out the drilling template image.
2. Beforedrillingplacetapeonthesurfacewheretheholewillbedrilled.
3. ChoosealocationonthesinkorbenchtopwheretheUltraStreamventedfaucet
spoutmayowintothesinkbothwhenitisonandwhenitisoff.
4. Centre mark the hole.
5. Drillthehole(NOTE:Alwaysuseanexpertwhendrillingintostoneormarble
benchtops).
6. Removesharpedgesanddeburrthehole.Thisistoprotectyourhandsandthe
tubeswhenfeedingthetubesthroughthehole.
For videos, help and support go to www.alkaway.com.au/support
1. Turnoffthecold-watersupplyby
theshut-offvalvebelowthesinkor
at the house water mains.
2. After shutting off the water, open
the kitchen faucet to drain out
the remaining water in the line.
Optional,turnonagardentapto
drain the water line.
3. Place a container under the shut
off valve to capture any water left
in the system.
4. Disconnectthecold-waterlineby
unscrewingthebraidedtubenut
(seeimagesaandb).
5. Install the cold-water connector
(the Angle Stop Valve). Ensure it’s
intheOFFposition,asshownin
images c and d).
6. Reconnect the cold-water line (the
braidedtube)byscrewingontothe
installed cold-water connector.
5

6
1. First, unscrew the faucet nut. Then remove the faucet
nutandblackwasherandputaside.
3. Install metal inlet tubes
2.UnscrewthetubenutfromthethreeMetal Inlet
Tubes.
3.Laythefaucetatonatable,withthetaphandlefacing
totheright,asshown.Nowlookingatthethreaded
holesinthebottomofthefaucet;
- The top hole is for the shortestmetalinlettubes.
- The bottom right hole is for the medium sized metal
inlettube.
- And the bottom left is for the longestmetalinlettube.
4. Screw in the shortest Metal Inlet Tube into the top
holebyhand.
6.Nextscrewinthemedium-sized Metal Inlet Tube
tubeintothebottomrightholebyhand,thentighten
with a spanner.
7. Finally screw in the longest Metal Inlet Tube into the
bottomleftholebyhand,thentightenwithaspanner.
Note:Forclarity,imagesareshown
withoutthelargerthreadedtube.
5.PositionthespanneronthehexsectionontheMetal
InletTubestotighten.

1.Attachingthe¼”plastictubes.
a.The REDtubeconnectstothe
SHORTESTMetalInletTube
(high pressure line MUSTberedhose).
b.TheWHITEtubeconnectstotheMEDIUM
lengthMetalInletTube.
c.The BLUEtubeconnectstothe
LONGEST MetalInletTube.
2.Attachedthedifferentcolouredtubes.Start
withtheREDtube,whichisattachedtothe
shortestMetalInletTubeconnector.Slide
thetubenutontothe¼”tube.Thenpush
theendofthetubeontoandovertheared
section of the connector and re-screw on
the nut.
Soakingtheendofthetubeinhotwaterwill
makeiteasiertopushthetubeon.
3.Repeatfortheothercolouredtubes(as
statedinstep2above).
4. Install tubes to faucet
5.Insert/feedthetubescarefullyinto
the drilled hole. If the hole is in a
stainless-steel sink, take care not to
cutorscratchthe¼”plastictubesas
they are fed into the hole.
6.Feedtheblackwasherandfaucet
nutunderthesinkoverthetubesand
backontothethreadedtube.And
then tighten.
Note:Youcancutthetubesto
beshorterifyoulike,butwe
recommend leaving them long
enough to pull the UltraStream
unitoutofthecupboardto
changethelter.
7

1. Lay the UltraStream onto its side.
2. Feedthewhitetubethroughthe
holeinthesideofthebase,then
insert it into the quick connect
insidethebase.
3. Turn the unit upright and insert
the size converter in the quick
connection in the top of the
UltraStream.
4. Insertthebluetubefromthe
faucet into size convertor quick
connection.
For videos, help and support go to www.alkaway.com.au/support
6. Install Pressure Limiting Valve (PLV).
1. Cutabout200mm(7to8”)
offtheredtube(cleanly
cutthetubeatrightangles
ensuringnoburrs).
2. Insertoneendofthetube
into the quick connect of the
cold-water connector.
3. Insert the other end into the
PLV,ensuringtheowarrow
is pointing away from the
cold-water connector.
4. Connecttheredtubecoming
down from the faucet into the
other end of the PLV.
Installation Schematic
8

Leak Testing
1. Make sure cold water connector tap is turned off.
2. TurnwaterONatmainsorshutoffvalve.
3. Turnoncoldwaterconnectortapandlookforanyleaksontheredtube.
If leaking,turnoffthewater.Checkthattheleakingtubeisrmlyinserted
intotheconector.Ifthereisstillaleak,removethetubefromtheQuick
Connectionandre-cuttheendofthetube.
4. NextturnONtheUltraStreamfaucetandcheckforleaksontheyellowand
bluetubeconnections.
Testing pH
How to test the pH of your water.
1. Add2-3dropsofpHreagentto30mlofwatertobetested.
2. Mix well.
3. Comparethenalcolourofthesolutiontotheenclosedcolourcharttoget
yourreading(It’sagoodideatouseawhitebackground).
4. pHColorReadingspH<7Acidic,pH=7Neutral,pH>7Alkaline.
Setting the Flow Rate
HowtogetthecorrectwaterowratefromyourUltraStream.
1. Usethetaponthecold-watersupplytocontroltheowrate.
2. A¼”turnonthetapwilladjusttheowfromFullyOntoOff.
3. Visuallywatchtheowfromthefaucetwhileadjustingthetap.Onceyouhave
amoderatestreamofwaterfromthefaucet.Recordthetimeittakestollup
a1Liter(0.25Gallon)bottle.Ifitisbetween30-60secondsthentheowrate
isnowsettobetween1-2Litersperminuteor0.25-0.5Gallonsperminute.
7. Connecting UltraStream Unit
(see Quick Connect Connector Instructions page 2)
1. Lay the UltraStream onto its side.
2. Feedthewhitetubethroughthe
holeinthesideofthebase,then
insert it into the quick connect
insidethebase.
3. Turn the unit upright and insert
the size converter in the quick
connection in the top of the
UltraStream.
4. Insertthebluetubefromthe
faucet into size convertor quick
connection.
9

Troubleshooting
Slow or No Water Flow
• Checktheblue/whitetapunderthebaseoftheUltraStream.Adjustthe
bluetapsothatitisin-linewiththeinlethose(thefullyopenposition).
• Doyouhaveanypre-ltersattached?Ifso,removethehosefromthe
bottomoftheUltraStreamandmakesureyouaregettingwaterow.
• Make sure the hoses aren’t kinked or twisted.
• If your UltraStream is slowlyreducinginow,itmaybethatitisnearingits
end of use.
• Yourltermightbeblockedandneedstobereplaced(highsediment
watermayrequireaspecialsedimentpre-ltertopreserveyour
UltraStreamlter’slife).
Leaking Water From Connectors
• RemovetotubefortheQuickConnectconnectorandre-cutends.
• TrypushingthetubefurtherintoQuickConnecttting(seehandytips
page3).
UltraStream Spurts
• Thisisduetothehydrogeninfusedinthewater.Thiswateristhebestto
drink.
Dripping UltraStream
• Whenwaterisincontactwiththeltermediaitcreatesmolecular
hydrogen in the water. Some hydrogen will leave the water as a gas
whenthelterisnotinuse,andthisgasmaypushalittlewateroutof
the UltraStream, producing a drip. This drip will usually slow down and
stopwithinacoupleofweeks.Rememberthisisnotaleak,itissimplyan
effect of excess molecular hydrogen production.
Leaking From the UltraStream Faucet
• Overtimeandrepeateduse,thefaucet’sinternalmechanismmay
becomeloose.Thereisasimplex.Visitoursupportpageforavideoon
howitisdonewww.alkaway.com.au/support/.
No pH Reading
• YouneedtouseliquidpHReagentsimilartowhatwassuppliedwithyour
UltraStream. pH strips or Litmus paper will not give you a correct reading.
• pHReagentmightbeoutofdateorstoredincorrectly.
• Itmightbetimetoreplaceyourlter.
10

11
Pre-Filters
Optional Extra’s
Ourpre-ltersselectionisspecicallydesignedtoprovideanextralayerof
protectionforyouandyourfamily.Wehaveshownourbest-sellingoptionsbelow
buttherearemanymoreoptionsavailableonlineatwww.alkaway.com.au.By
incorporatingthisoptionalpre-lter,youcanextendthelifespanofyourUltraStream
andimprovetheoverallltrationefciency(pre-lterssoldseparately).
Submicron Depth Filtration –
Manufactured using a proprietary,
patented, electro-adsorptive media
technology,arecapableofremoving
submicronpathogensandinorganic
contaminants through electro-adhesion
and ion exchange.
Extra Fluoride removal –
TheUltraStreamwillremoveupto78%
ofuoride,theuoridepre-lterremoves
upto75%-80%andtogethertheywill
removeupto95%-99%oftheuoride
from your water.
Sediment areas –
Recommended for rainwater tanks and
high sediment states like SA or WA.
Simply install the sediment paper pre-
lterinlinewithyourUltraStreamwater
ltersystem.Helpsprotectthelterfrom
clogging up prematurely.

v4.6
Doyouhaveastoryaboutyourwater?
We’dloveyoutoshareit:
Email us at info@alkaway.com.au
AlkaWay Support | support.alkaway.com
CopyrightAlkaWay2023
AlkaWay Australia | www.alkaway.com.au
AlkaWay United States | www.alkaway.com
AlkaWay Canada | www.alkaway.ca
AlkaWay UK/EU | www.alkaway.co.uk
AlkaWay Singapore | www.alkaway.sg
Table of contents