AlluGuard Qompact Q2R User manual

GB
Original operation instructions
Comfort Garage Door System made of Aluminium
Qompact® Q2R
07.2018

2Original operation instructions Qompact® Q2R – 07.2018
Table of Contents
1. General safety instructions ...................... 3
1.1 Intended use ..................................3
1.2 Target group ..................................3
1.3 Guarantee ....................................4
2. Product overview .............................. 5
2.1 Assembly measurements......................5
2.2 Scope of supply ...............................6
3. Installation .................................... 6
3.1 Preparing for installation ......................6
3.2 Preparation for installation ....................8
3.3 Mount the rails................................8
3.4 Connect the control unit. . . . . . . . . . . . . . . . . . . . . 11
3.5 Mount the box .............................. 14
3.6 Positioning of the end limits................. 14
3.7 Connection of the contact bar ............... 15
3.8 Install the covers ............................ 16
3.9 Mount the emergency release (optional)..... 16
3.10 Completing the installation ................. 17
4. Operation ....................................17
4.1 Hand transmitter ........................... 17
4.2 Emergency hand crank ...................... 17
5. Maintenance .................................18
6. Disassembly ..................................19
7. Disposal .....................................19
8. Appendix.....................................19
8.1 Technical Data .............................. 19
8.2 Declaration of conformity ................... 20
8.3 Declaration of performance ................. 20
Regarding this document
– Original instruction manual.
– Part of the product.
– Read these instructions carefully before use and keep
them in a safe place for future reference.
– Protected by copyright.
– No part of this manual may be reproduced without our
prior approval.
– Subject to alterations in the interest of technical
progress.
– All dimensions are given in millimetres.
– The drawings are not true to scale.
Safety instructions
DANGER!
Safety instruction on a hazard with a high level of risk!
Non-compliance will result in death or severe injury.
WARNING!
Safety instruction on a hazard with a medium level of
risk!
Non-compliance may cause death or severe injury.
CAUTION!
Safety instruction on a hazard with a low level of risk!
Non-compliance may cause minor or moderate injuries.
NOTICE
Safety instruction on a hazard with a low level of risk!
Non-compliance may cause damage or destruction of the
product.

Original operation instructions Qompact® Q2R – 07.2018 3
1. General safety instructions
DANGER!
Failure to comply with the operating instructions could
result in life-threatening danger!
These operating instructions contain important infor-
mation for ensuring safe use of the product. Particular
attention is drawn to potential hazards.
yPlease read these instructions carefully and in full.
yFollow the safety instructions contained in these
operating instructions.
1.1 Intended use
– This door system is intended exclusively for domestic
use (on average 2000 cycles a year) and is not licensed
for continuous operation. The motor unit must only be
operated in dry spaces.
1.2 Target group
– Installation, connection, setting and maintenance in
operation:
qualied, trained specialist personnel.
– Operation, inspection and servicing:
the operator of the door system.
Requirements to be met by qualied and trained specialist
sta:
– Knowledge of the general and specic safety and
accident-prevention regulations.
– they have knowledge of the relevant electrical regulation,
– Training in the use and care of appropriate safety
equipment.
– Adequate instruction and supervision by qualied
electricians.
– The ability to recognise hazards that can be caused by
electricity.
– Knowledge of the application of the following standards
– EN 12635 (“Doors and gates - Installation and use”),
EN 12453 (“Safety in use of power operated doors -
Requirements”),
– EN 12445 (“Safety in use of power operated doors -
Test methods”),
– EN 13241-1 (“Industrial, commercial and garage
doors and gates - Product standard - Part 1:
Products without re resistance or smoke control
characteristics”).
Document icons
yInstruction requiring action
– List, itemisation
)Factory settings
✓Check
*Hint
➔Reference to other sections of this document
Reference to separate documents that must be observed

4Original operation instructions Qompact® Q2R – 07.2018
Requirements to be met by the operator of the door system:
– Knowledge and safekeeping of the instruction manual.
– Safekeeping of the test book for future reference.
– Knowledge of general safety and accident-prevention
regulations.
– Instruction of all door system users of proper usage.
– Provisions to ensure the door system is regularly
inspected, tested and maintained by fully trained and
qualied professionals according to the manufacturer’s
instructions.
Special requirements apply to the following users:
– Children aged eight and above.
– Persons with with reduced physical, sensory or mental
capabilities.
– Persons with a lack of experience and knowledge.
These users may be involved only in operation of the device.
Special requirements:
– The users must be supervised.
– The users must have been briefed on how to use the device.
– The users must understand the dangers involved in
handling the device.
– Children are not allowed to play with the device.
1.3 Guarantee
– A guarantee with regard to function and safety can only
be granted if installation is carried out in a competent
way and these instructions are followed exactly.
– If you do not observe the warnings, you run the risk of
personal injury and damaging the door system.
– The manufacturer is not responsible for any damage
that occurs if the safety guidelines are not observed.
– To avoid installation and operating errors, the installation
and operation must be carried out exactly according to
these installation and operating instructions. The door
and motor unit may only be operated after reading
these installation and operating instructions. These
installation and operation instructions must be handed
over to the end user who should store them carefully.
– The door systems are manufactured in accordance
with guidelines outlined in the conformity declaration
and standards and left the factory without fault and
in compliance with safety standards. The specialist
trader carrying out the installation conrms the correct
installation according to DIN EN 12635 by means of
his own individual conformity declaration. The emitted
sound pressure level is less than 70 kB(A).
– Maintenance must be performed on the door and motor
unit before start-up and at least once a year thereafter.
All maintenance work must be documented in the
inspection logbook.
– The guarantee for the door and motor unit is only valid if
original accessories are used. Any replacements must be
carried out by qualied professionals. The manufacturer
cannot be held responsible for any damages resulting
from the use of other replacement parts or from
incorrect installation.
– Wear and tear parts such as springs, bowden cables,
door cables, rollers, pulleys, tooth belts, seals, batteries,
fuses, bulbs, locks and locking mechanisms are not
included in the standard guarantee.
Further safety instructions are given in the relevant sections
of the document.
➔“3. Installation”
➔“4. Operation”
➔“5. Maintenance”
➔“6. Disassembly”
Manufacturer:
Alulux GmbH
Messingstraße 16
33415 Verl
Phone: 0 52 46/9 65-0
Fax: 0 52 46/9 65-2 90

Original operation instructions Qompact® Q2R – 07.2018 5
2. Product overview
2.1 Assembly measurements
View from above
b
76 c 76
d
76
45
32
Side view
76
46
30
h
g
a
e
f
End slat a
AEG 400 40
AEG 400 with EKL 70
Type Facing cap e
SG 20 / SG 90
165 167
180 183
205 207
SGF
165 169
180 184
205 210
b Finished dimension curtain = unit width - 75
c Clear width
d Unit width = clear width + 152
e Box height
f Clear height
g Length of guide rail
h Unit height

6Original operation instructions Qompact® Q2R – 07.2018
2.2 Scope of supply
2.2.1 Standard scope of supply
4
1
23
5
7
6
1 Box with round shaft and curtain
2 Guide rail cover
3 Guide rails
4 Emergency eye holder (only for version NHK)
5 Manual emergency crank (only for version NHK)
6 Emergency eye (only for version NHK)
7 Wall bracket (only for emergency hand crank (NHK)
version)
Fixing materials for tting to the wall and ceiling are not
supplied as part of the package.
2.2.2 Control unit supply package (optional)
8
8 Control unit with mains plug
3. Installation
3.1 Preparing for installation
DANGER!
Life-threatening danger due to electric shock!
Touching live parts may cause electric shock, burns, or
death.
yIt is vital that you disconnect the operator system from
the power supply before commencing cabling work.
yTake measures to ensure that the power supply
remains disconnected for the duration of the work.
yObserve the local safety regulations.
yIt is imperative that you lay power cables separately
from control cables. The control voltage is 24 V DC.
CAUTION!
Risk of injury due to improper operation!
Size and weight of the product require a lot of power
when assembling. If the product falls, serious injuries may
result.
yThe garage door system should always be mounted by
at least two persons.
yBe sure to stay on rm ground when mounting.
yMake sure that no other persons are present in the
working area.
NOTICE
Danger of material damage due to improper assembly!
Non-compliance with the following instructions may
result in property damage or malfunction.
yEnsure that the oor is at its nished level.
yEnsure that the walls and ceiling are already plastered.
yThe travel path of the door must be free of all
obstructions (e.g. nails, sockets, cables, etc.) to avoid
damage to the door.
yEnsure that suitable xing material is available for the
foundation.
yPrefabricated garages must be drilled using a depth
stop.
yOnly mount the motor unit when the door is closed.
yMount all pulse generators and control devices (e.g.
radio code keypad) in the range of sight of the door and
at a safe distance from any moving parts of the door.
The device must be mounted at least 1.5 m above the
ground.
yAfter installation is complete, ensure that no door parts
extend onto the public footpath or the street.
yCheck the installation situation to ensure a smooth
door movement.

Original operation instructions Qompact® Q2R – 07.2018 7
For garages without a second entrance:
yEquip the garage door inside and outside with an
emergency hand crank to open/close the garage even in
the event of a disruption.
Checking the brickwork
yUnderlay any slanted brickwork.
yUnderlay any uneven brickwork.
Auftraggeber
AUF.-NR.: XXXXXXXXX POS. XXX.X
BreiteHöhe
XXXX XXXX
Qualitätssicherung:
XX.XX.XXXX
KOM.: XXX.XXXXX
a b
b
a
Measurement check
yCompare the installation location with the specications
on the box sticker.
a Element width
b Element height
If the installation location does not comply with the
specications
Please contact your specialised retailer.
If the installation location complies with the specications
yCheck the scope of supply for completeness. If there
are any parts missing, please contact your specialised
retailer before you begin the installation work.

8Original operation instructions Qompact® Q2R – 07.2018
3.2 Preparation for installation
These instructions describe the installation at a standard
location. The illustrations refer to door systems with shafts
pre-tted in the factory.
NOTICE
Danger of material damage due to improper assembly!
Always follow the instructions below to avoid material
damage and malfunctioning.
yUnpack all parts with great care.
yUse the original box as a protective underlay.
yMake sure the connection cable on the side of the box
is not damaged.
yDo not use the tubular motor when it is lying at on
the ground, otherwise the safety brake jams.
yThe door system then no longer meets the safety
requirements.
3.2 / 1
yUnpack the box.
3.3 Mount the rails
3.3 / 1
160===160
160===160
a
a
13
13
160
13
Guide rail length (a) No. of holes
– 1200 2
1201 – 2500 3
2501 – 3000 4
yDetermine the position of the required xing holes.

Original operation instructions Qompact® Q2R – 07.2018 9
3.3 / 2
ø 6,0
ø 9,5
yDrill the xing holes into the groove of the guide rails at
the positions you found out.
Drill diameter:
Wall side ø 6.0 mm
Door side ø 9.5 mm
3.3 / 3
yPush the guide rails onto the plastic pins on the box as
follows:
The bell-mouth entry is next to the insert opening and
shows to the inside of the door to the top.
CAUTION!
Risk of injury due to improper operation!
Size and weight of the product require a lot of power
when assembling. If the product falls, serious injuries may
result.
yEnsure the following step is always carried out by two
people.
yMake sure the box and the guide rails cannot fall
down.
NOTICE
Risk of damage to the door system and wall due to
improper assembly!
Avoid direct contact with the wall, as this may damage the
door system and/or the wall.
yCarefully lift the box and the guide rails into the
desired position.
yAvoid scraping the box and guide rails on the wall.
*For the next installation step we recommend to have the
required screw clamps and spirit level at hand.
*Depending on the height of the ceiling there are two
versions to install the box and the guide rails. For a low
ceiling version 2 must be taken.
3.3 / 4
Version 1
Ceiling height ≥ unit height + 30 mm
NOTICE
Risk of material damage due to improper installation!
Twisting or bending of the runner rails will destroy the
pins.
yRaise the box carefully.
yMake sure the runner rails are not twisted or bent
when erecting the box and guide rails.
Box and guide rails are aligned in a matching way.
yLift the box together with the guide rails so that it stands
against the door opening.
ySecure this position with screw clamps.

10 Original operation instructions Qompact® Q2R – 07.2018
3.3 / 5
Variante 2
Deckenhöhe < Elementhöhe + 30 mm
NOTICE
Risk of material damage due to improper installation!
Twisting or bending of the runner rails will destroy the
pins.
yRaise the box carefully.
yMake sure the runner rails are not twisted or bent
when erecting the box and guide rails.
Box and guide rails have to be turned into the tting
position. If necessary, the guide rails have to be taken o the
box and re-mounted after right positioning.
yLift the box together with the guide rails so that it stands
against the door opening.
ySecure this position with screw clamps.
3.3 / 6
OFF
b
b
yAlign the guide rails as follows:
– The bottom side has to be ush with the upper level
of nished oor (OFF).
– The box must be in horizontal position.
– The guide rails must be aligned perpendicular.
– The distance between the outer edge of the guide
rails corresponds to the unit width. This measure
must be identical on the total height.
b Unit width

Original operation instructions Qompact® Q2R – 07.2018 11
3.3 / 7
a
yDrill through the pre-drilled holes of the guide rails into
the brickwork.
Material a b c1
Solid material2≤ 40 30440
Perforated
material3≤ 60 50560
a Drilling depth
b Length of wall plug
c Length of screw
1Wood or chipboard screw ø 4 – 5 mm
2For example, concrete, solid brick (facing brick),
sand-lime brick, porous concrete (Ytong)
3For example, perforated brick, sand-lime perforated brick,
lightweight concrete hollow brick
4Fischer plug type SX 6
5Fischer plug type SX 6 L
3.3 / 8
yInsert the dowels.
yScrew on the guide rails.
3.4 Connect the control unit
3.4 / 1
Refer to the supplied separate instructions (installation
instructions SOMFY, point 3.4) when installing and
commissioning the control unit.
Right roller variant
3.4 / 2
yConnect the plug to the control unit.

12 Original operation instructions Qompact® Q2R – 07.2018
Left roller variant
NOTICE
Risk of damage due to soiling!
The action of moving parts may be limited by drilling dust.
yAlways remove any drilling dust from the door system
after drilling holes.
3.4 / 3
Ø 16
yDrill the hole for cable routing through the brickwork.
3.4 / 4
yFeed the cables to the control unit.
3.4 / 5
yOpen the control unit.

Original operation instructions Qompact® Q2R – 07.2018 13
3.4 / 6
AB
1 2 3 4 5 6
CD
yConnect the cables as follows:
A Blue terminal block, motor
B Red terminal block, safety brake
C Connection cable, motor
D Connection cable, safety brake
A C
RR - Control
inside left /
RR - Control
inside right /
LR - Control
inside right
LR - Control
inside left
1 yellow / green yellow / green
2 brown black
3 blue blue
4 black brown
B D
RR - Control
inside left /
RR - Control
inside right /
LR - Control
inside right
LR - Control
inside left
5 green
6 white
3.4 / 7
A
C
B
yInsert the terminal blocks:
A Blue terminal block, motor
B Red terminal block, safety brake
C Green terminal block, curtain

14 Original operation instructions Qompact® Q2R – 07.2018
3.5 Mount the box
3.5 / 1
yClose the door.
yUnscrew and remove the maintenance cover.
NOTICE
Danger of material damage due to dirt or contamination!
The motion of movable parts can be restricted by the
presence of drilling dust.
yClean the door system after all drilling work to remove
any dust that may result from it.
3.5 / 2
yFix the box to the wall using appropriate plugs and
screws:
– Above the shaft, use a fastening strap.
3.6 Positioning of the end limits
For the installation and initial operation of the tubular
motor please look up the enclosed separate instructions.
yConnect the mounting cable to power supply.
NOTICE
Risk of material damage due to improper end limit
adjustment!
An incorrectly adjusted lower end limit may result in
damage to the door curtain, the shaft and the tubular
motor.
yWhen adjusting the lower end limit, make sure that
the slats are not pushed together. The end limit is
reached when the end slat comes into contact with the
oor. Do not apply any further pressure.
Bottom end limit
3.6 / 1
yAdjust the lower end limit.

Original operation instructions Qompact® Q2R – 07.2018 15
Upper end limit
3.6 / 2
a
End slat a
AEG 400 40
AEG 400 with EKL 70
yAdjust the upper end limit.
3.7 Connection of the contact bar
For installation and initial operation of the control unit
please look up the enclosed separate instructions.
NOTICE
Danger of material damage due to improper assembly!
An incorrectly guided spiral cable may cause
malfunctioning or damage.
yPay attention to the following points during assembly:
– The spiral cable must not be extended.
– The spiral cable must be laid so as to ensure that
the tension at both end positions is roughly equal.
– The spiral cable must not impede the movement of
the door.
3.7 / 1
yClose the control unit.

16 Original operation instructions Qompact® Q2R – 07.2018
3.8 Install the covers
3.8 / 1
yScrew the cover onto the box.
3.8 / 2
yInstall the guide rail covers.
3.9 Mount the emergency release (optional)
3.9 / 1
yTravel the door in CLOSED position.
yScrew the emergency eye holder on the emergency eye.
3.9 / 2
yInsert the end of elongated ring lug tool as far as it will
go into the respective opening in the tubular motor.
*When removing the elongated ring lug tool from the
opening, the protective device against the elongated ring
lug tool will be destroyed and must be replaced with a
new one.
Keep the remaining protective devices against the
elongated ring lug tool in a safe place.

Original operation instructions Qompact® Q2R – 07.2018 17
3.10 Completing the installation
3.10 / 1
yRemove protective lm from all visible aluminium
surfaces.
4. Operation
WARNING!
Danger of injury due to uncontrolled operation of the
door!
yOperate the controls or the hand transmitter only
when there are no persons or objects in the path of
the door.
yEnsure that the controls and the hand transmitter are
never used by children or unauthorised persons.
yEnsure that the hand transmitter cannot be operated
by accident (in a trouser pocket, for example).
NOTICE
Danger of damage to property due to uncontrolled
movement of the door!
When the door moves, the hand chain can get caught and
this could result in damage (in the case of ceiling-mounted
supports for example).
yEnsure that there are no obstacles blocking the path of
the door or the hand chain.
4.1 Hand transmitter
Further information about the supplied hand
transmitter can be found in the respective documents
(installation instructions SOMFY, point 9).
4.2 Emergency hand crank
NOTICE
Danger of damage to property due to uncontrolled
movement of the door!
When the release mechanism is operated, uncontrolled
door movements could occur:
– If the door springs are weak or broken.
– If the door is not balanced.
yOnly use the emergency hand crank to operate the door
in the event of emergencies.
yWhen using the emergency hand crank to open/close
the door, do it carefully and at a moderate speed!
4.2 / 1
If necessary the door can be opened or closed with the
enclosed emergency hand crank without motor operation.
4.2 / 2
yPut the emergency hand crank into the emergency eye.
yMove the door up or down by turning the emergency
hand crank.

18 Original operation instructions Qompact® Q2R – 07.2018
4.2 / 3
yAttach the “Rotational directional“ sticker onto the
emergency hand crank according to the installation
situation.
5. Maintenance
Inspections by the operator
DANGER!
Life-threatening danger due to electric shock!
yIt is vital that you disconnect the operator system from
the power supply before cleaning. Take measures to
ensure that the power supply remains disconnected
for the duration of the cleaning operation.
To ensure safe operation and a long service life, the operator
must inspect the condition of the door system.
The inspection must be conducted at least once every three
months and whenever the door system has been subjected
to external force (e.g. collision, storm).
Before starting work on the door system, the operator
system must always be disconnected from the power
supply.
yCheck once a month that the operator system reverses
when the door touches an obstacle. To check this, place
an obstacle, 50 mm in height, in the path of the door in
the direction of travel.
yCheck the settings of the automatic cut-out in the OPEN
and CLOSE directions.
yCheck all the moving parts of the door system and door
operator system.
yCheck the door system for signs of damage or wear and
tear.
yCheck the power supply cable for signs of damage.
For safety reasons, if the power supply cable is damaged
it must be replaced by the manufacturer or his customer
service department, or by a similarly qualied person.
yCheck for any unusual noises when the door is moving.
Checks by qualied professionals
Power-operated windows, doors and gates must be
inspected by fully trained and qualied professionals
(written inspection records must be kept) at regular
intervals of no more than one year.
yUse a suitable closing door measuring device to check
the driving power.
yIf necessary, replace damaged or worn parts.
Replacement of parts
When parts are replaced, only original accessories must be
used. Any replacements must be carried out by qualied
professionals.
Certain parts must be replaced after a specic number of
door movements.
Safety-relevant components must be replaced without fail
once their lifetime has been reached.
– Motor and control:
Failure is possible after 30,000 - 50,000 cycles.
– Door curtain and guide rails:
Failure is possible after 80,000 - 100,000 cycles.
– Securing steel springs:
Failure is possible after 20,000 cycles.
1 cycle =
1 complete door movement (door in closed position – door
opens – door closes again).
3 cycles per day (average for private use) results in approx.
1,100 cycles per year.
Care and cleaning
DANGER!
Life-threatening danger due to electric shock!
yIt is vital that you disconnect the operator system from
the power supply before cleaning. Take measures to
ensure that the power supply remains disconnected
for the duration of the cleaning operation.
Only a dry method of cleaning must be used to clean
electrical components (such as light barriers, controls).
Light barriers must be cleaned every three months at the
latest.
yClean the electrical components with a dry cloth.
yClean the door elements with a damp cloth using a
gentle non-abrasive cleaning agent.
It is not necessary to lubricate the door system.

Original operation instructions Qompact® Q2R – 07.2018 19
6. Disassembly
DANGER!
Life-threatening danger due to electric shock!
yIt is vital that you disconnect the operator system from
the power supply before disassembly. Take measures
to ensure that the power supply remains disconnected
during disassembly.
WARNING!
Possibility of serious injury due to falling components!
yBefore disassembling the operator system, secure it to
prevent it from falling.
yObserve all the applicable health and safety
regulations.
Disassembly must be carried out by fully trained and
qualied professionals in reverse order to assembly.
7. Disposal
Do not dispose of old equipment or batteries
with the normal household waste!
When disposing of the door system, the various materials
must be separated and recycled.
yDispose of old devices at a waste collection centre for
electronic waste or via your specialist dealer.
yDispose of old batteries in a battery recycling container
or via a specialist dealer.
yDispose of the packaging material in the special waste
collection containers for paper, cardboard and plastic.
8. Appendix
8.1 Technical Data
Electrical data
Rated voltage, regional
deviations are possible V 230 / 260
Rated frequency Hz 50 / 60
Current input A 1.2 – 1.7
Power consumption in
operation kW 0.27 – 0.4
Control voltage V DC 24
Protection category of motor
unit IP 44
Protection class II
Mechanical data
Nominal torque Nm 40 – 120
Travel speed mm/s 140
Opening time (door specic) s approx. 18
Environmental data
Motor unit dimensions mm 544 – 681
Weight (door specic) kg approx. 5.0
Sound pressure level dB(A) < 70
Temperature range
°C -25
°C +70
Characteristics/safety functions
The tubular motors are designed for short-term operation.
After exceeding the duty cycle, the thermal overload
protection will automatically shut down the motor. After
a cooling-down phase of approx. 15 minutes, the tubular
motor will be ready for operation again.
– Nominal duty cycle
according to VDE test
(233 V)
approx. 4-5 minutes,
depending on the type
– Eective operating time
in normal operation
(220 V)
approx. 7-9 minutes,
depending on the type

20 Original operation instructions Qompact® Q2R – 07.2018
8.2 Declaration of conformity
Door manufacturer:
Alulux GmbH
Messingstraße 16
33145 Verl
hereby declares that the Resident ceiling-mounted door
system complies with the EC Directives and standards
named below.
Type designation:
According to the manufacturer’s information the product
complies with the following regulations for its properly
functioning state. This declaration will lose its validity if
any alterations are made that have not been discussed and
agreed with the manufacturer.
No alterations to the drive are permissible without the
relevant EC Certicate of Conformity from the manufacturer
of the drive with reference to the above-named door!
Directives applied:
– EMV 2014/30/EU
– 2006/42/EG Machinery directive
Directives:
– EN 13241-1: 2011
Standards:
– Sub-standards of EN 13241-1:2011
– EN 12604
– EN12605
– EN 12424
– EN 12444
– EN 12635
– EN12453
– EN 12445
Verl, 12.04.2018 Signature Reoch
Place, Date Managing Director
Signature Humpe
Authorized for documentation
8.3 Declaration of performance
Type inspection: Qompact Q2R
Purpose of use according to DIN EN 13241-1:2011 Doors –
comfort garage door
Alulux GmbH, Messingstraße 16, 33415 Verl
Authorised document representative: Humpe
Certication according to rating system 3 of the building
products guideline 305/2011/EG has been eected through
the manufacturer.
When using the product in its intended way it meets the
essential featuresof the below mentioned norms.
Type inspection:
CENTRE SCIENTIFIQUE ET TECHNIQUE DU BÂTIMENT
Etablissement de Grenoble –24 rue Joseph FOURIER –
38400 SAINT MARTIN D´HERES No. 1-1542
Declared Performance
Essential features /
Performance
Norm
Resistance against wind
load. Wind load category: see
following specications or
the type sign..
EN 13241-1:2011
(chapter4.4.3)
EN 12424:2000
Resistance against incoming
water: NPD* (Category 0)
EN 13241-1:2011
(chapter4.4.2)
EN 12425:2000
Release of hazardous
substances: NPD*
EN 13241-1:2011
(chapter4.2.9)
Thermal resistance: NPD* EN 13241-1:2011
(chapter4.4.5)
Air permeability: NPD*
(Category 0)
EN 13241-1:2011
(chapter4.4.6)
Safe opening: fullled EN 13241-1:2011
(chapter4.2.8)
Safe closing: fullled EN 13241-1:2011
(chapter4.3.3)
Resistance against wind load:
Qompact Q2 Category 5
Resistance against incoming water:
Qompact Q2 Category 0
Performance of the product pursuant to number Q2R cor-
responds to the specied performance. This Declaration of
Performance is issued under the sole responsibility of the
manufacturer identied above.
Verl, 12.04.2018 Signature Reoch
Place, Date Managing Director
Table of contents
Other AlluGuard Garage Door Opener manuals
Popular Garage Door Opener manuals by other brands

Automatic Technology
Automatic Technology GDO-4 EasyRoller installation instructions

Genie
Genie GCL-GCX manual

Chamberlain
Chamberlain Whisper Drive Security+ 182671D owner's manual

MOX
MOX C40 Series Instruction and warnings for the installer

Craftsman
Craftsman 139.53915SRT- 1/2 HP owner's manual

Craftsman
Craftsman 139.5391 owner's manual

Craftsman
Craftsman 139.10158 owner's manual

Autoglide
Autoglide CASA-M Series product manual

Craftsman
Craftsman 139.53535SRT1 owner's manual

LIFTPRO
LIFTPRO LPO0600 Installation instructions & user guide

Chamberlain
Chamberlain WhisperDrive 182665D owner's manual

Meccanica Fadini
Meccanica Fadini APROLI 480 instruction manual