ALORAIR Storm Elite User manual

Storm Elite
14021 NC Highway 50 Surf City, NC 28445
Seaira Global LLC
Installation and Operation Manual
910-660-0962

※
Safety Notes
DEHUMIDIFIERS
• The Storm Elite dehumidifier must always be connected using a grounded electrical
connection as required for all electrical appliances. The warranty is voided and all respon-
sibility for the operation transfers to the owner if non-grounded wiring is utilized.
• Your Storm Series dehumidifier must be maintained and serviced by qualified technicians.
• Storm dehumidifiers are intended for use only when the unit is installed in a level and
upright position. Operating the unit in any other position could cause water to come in
contact with the electrical components.
• Before moving the dehumidifier, turn off the unit and allow the pump reservoir to empty (if
unit is already off, press “P” button to confirm drain reservoir is empty). After the pump has
finished operation, unplug the power cord and relocate the unit to the desired position.
• If the inside of the machine has gotten wet for any reason, the unit should be opened and
allowed to dry thoroughly before reconnecting it to electric and restarting.
• For proper operation, neither the inlet or discharge should be positioned against a wall. A
minimum of 8” clearance between the Storm and any obstruction is required.
• Do not insert any objects or fingers into the inlet or discharge.
• All work on the machine should be done with the unit off and unplugged.
• Do not spray water or cleaner directly on the exterior of the Elite. Only use a damp cloth
to clean the exterior and always unplug the unit first.
• Do not use unit as shelf or device to hang clothes as this could cause damage to unit.
• Do not stand on the machine.
※

※Table of Contents
DEHUMIDIFIERS
Introduction..................................................................................................01
Unit Overview...............................................................................................03
Operating Instructions..................................................................................04
Preparing the Unit for Use............................................................................09
Maintenance & Repair..................................................................................11
Storing Your Dehumidifier.........................................................................................15
Troubleshooting............................................................................................15
Warranty.......................................................................................................17
Readiness Checklist.....................................................................................19
Service Checlist............................................................................................20
※

DEHUMIDIFIERS
※Introduction
Identification
-1 -
Congratulations on purchasing a Storm Elite dehumidifier! The Storm Elite comes
with an extensive warranty plan. To ensure you are eligible, be sure to note the serial
number and date of purchase. The serial number can be found on the data on the
back of the unit.
Model Name: Storm Elite
Serial Number:__________
Date of Purchase: ___________
Customer Service
• Contact your installing contractor
• Contact Seaira Global: 910-660-0962
※
• 125 Pints Per Day
• High COP: 2.4 L/kWh
• Only 63 dBa
• Automatic humidistat
• Built-in Pump with Overflow Protection
• Self Monitoring System
• Eco Friendly R410A Refrigerant
• Easy Access to Internal Components
• Auto Restart After a Power Outage
• Unit Can Be Ducted, If Necessary
Features
For additional questions concerning the operation fo your dehumidifier, please

How Your Storm Dehumidifier Works
Installation
120 Volts may cause serious injury from electric shock.
WARNING
WARNING
DEHUMIDIFIERS
-2 -
The Storm Elite dehumidifier utilizes its integral humidistat to monitor the conditioned space.
Once conditions are outside the desired setpoint, the compressor energizes and air is
drawn across an evaporator coil. The evaporator coil is cooler than the dew point of the air
so water vapor will turns into liquid condensation. The air is then reheated through the
condenser coil and distributed back into the room.
1. Disconnect electrical power before servicing
2. Only plug unit into grounded electrical outlet
3. Do not use an extension cord
4. Do not use a plug adapter
Power Supply: 115V, 60 Hz AC Only 1 Phase
Outlet Requirement: 3-Prong, GFI
Circuit Protector: 15 Amp Time Delay Fuse or Circuit Breaker
Place the Elite in your desired location. The inlet of the machine should be at least 8”
from any obstructions. If the unit has been transported in a horizontal position, allow it to
sit in an upright position for at least 30 minutes before operating.
Do not use dehumidifier in an environment where corrosive or high VOC materials are applied.
Electrical Supply

Front View
Rear View
Handle
Wheel
Front Cover
Air Outlet
Access Latch
Control Panel
Power Cord
Tubing &
Cord Rack
Drain Tube
Connection
Air Intake
Air Filter
DEHUMIDIFIERS
-3 -
※
Unit Overview
※

-4 -
Operating Instructions
Control Panel Overview
OK
M
P
Menu
Up Button Down Button LCD Monitor
On/Off
Select/OK Drain Pump
P
M
DEHUMIDIFIERS
Press the on/off button once to power the dehumidifier on and begin operation. Once it is
powered on, the display will show room humidity levels unless another button is being
pressed. To power off the unit, press the on/off button one time.
NOTE: When the unit is turned off, the fan will run for 1 minute prior to shutting off. In addition, the
condensate pump will pump for approximately 15 seconds to drain the reservoir.
Press the pump button once to remove any water from the integral pump’s reservoir. This is
useful if you need to move the dehumidifier or plan on storing it for an extended period of time.
1. On/Off Button
2. Pump Button
3. Menu Button
Pressing the Menu button gives you the capabilitiy to access the settings. Continue pressing
the Menu button until your desired selection is flashing. Press the (OK) key to confirm that selection
and you will move to a submenu.
After you’ve completed your task, select “R” (return), then press the (OK) button to move back to the
previous menu. Alternatively, you can wait 10 seconds and you will automatically return to the main
screen.
From the main menu you can access:
• Humidity Settings: Adjust the humidity setpoint
• Timer Settings: Set up auto start time, auto stop time, and time cycles
• Temperature Scale Settings: Choose between Celsius and Fahrenheit for temperature
readings
NOTE: See “How to Change the Settings” for detailed programming instructions
※
※

-5 -
poweron
n
UnitO
OK
Inlet32℃76%
DEHUMIDIFIERS
Use this button to confirm a selection.
The up and down buttons are used to adjust the humidity or timer settings..
Please note that the LCD monitor will go blank if no buttons are pushed. Push any
button to activate the display.
• The display will Show “Power On” when the machine has been plugged in but not
started.
• The display will show “Unit On” when the machine is running. This display will
change after 2 seconds.
4. Select/OK Button
5. Up Button Down Button
6. LCD Display
Understanding the Display Screen
• The LCD interface shows two lines of data. The first line will display the room
temperature and humidity.
or
Job.T000
5
Humi.set50%
• The second line will alternate between showing the working time (Job T) and
Humidity Setpoint.
NOTE: The second line will change every ten seconds.
2. Display During Operation
1. Display WhileTurning on the Dehumidifier

Inlet32℃76%
Draining
Inlet32℃76%
Dig
ft
en
ros
ff
UnitO
Draining
Job.T000
5
089L fe
i.0H
or
DEHUMIDIFIERS
• When you press the “power off” button, two lines of data will be displayed. The top line will
read “Unit Off”. The bottom line will read “Draining” while the pump is being emptied
(approximately 15 seconds).
• Once the pump reservoir has drained, the contents of the second line will alternatively
show “job hours” and “total hours”, switching every 10 seconds until the one minute final
fan cycle is completed.
• When you press the “P” button to drain the pump, the second line of the display screen
will show draining. Draining will also appear during automatic draining while the dehumidi-
fier is operating.
• The display will show “defrosting” when the machine is in defrosting mode. If both “De-
frosting” and “Draining” are occuring simultaneously, “Defrosting” will show on the screen.
• When one of the timing settings is being used (auto start, auto stop, or timing cycle), that
information will show on the second line of the display
4. Display While Turning off the Dehumidifier
3. Display During Draining and Defrosting
5. Display While Using Timers
TimeOn00 05
TimeO000
5
ff
O000000
I11
Time Remaining Until Auto Start
Time Remaining Until Auto Stop
Time Remaining Until Cycle Starts
-6-

-7-
HumidTimer
TempUR
Humid
R
Setting
35%
DEHUMIDIFIERS
c. Press the menu key until the humidity level (bottom left of display) is flashing. It
will either say “Co” for continuous operation or a number for a specific percentage.
2. Timer Settings (Timer)
This selection allows you to set a timer for the unit to turn on or turn off. You can also set up
cycle timing, which lets you set up a repeating cycle of specific on and off durations.
b. Press the (M) button until “Humid” is flashing. Press (OK) to select this option.
The screen will show:
a. Press the Menu (M) button. The screen will show:
1. Setting the Humidity Level (Humid)
NOTE: As long as the machine is plugged into power, the settings can be changed. The unit does
not have to be operating to modify the setup.
How to Change the Settings
d. Use the Up or Down arrows to set the machine to your desired level. Press the
(ok) button when finished. The cursor will automatically move to the “R”, which will
be flashing. Press (ok) to confirm moving to the previous menu or wait 10 seconds
and you will automatically return to the main menu.
a. Press the menu key several times until the Timer button is flashing. Press the (ok)
button to confirm.
HumidTimer
TempUR
b. The screen will show: To.on, T.off, T.I/0, R
ff
noo
T
T
T
R
/
.
..
I0

-8 -
TimerOn
OR
ff
0000
DEHUMIDIFIERS
Option 1: Start Time (T.on Selection)
a. Press the (M) key until “T.on” is flashing. Press to the OK key to confirm your
selection. The screen will then show the first 00 positions flashing.
b. Press the Up and Down arrows to select your hour choice between 00-24.
Press the (Ok) key to confirm.
c. After the hour selection is confirmed, the minute option will flash. Use the
arrow keys to select, then press the (OK) key to confirm.
d. “OFF” will now flash on the screen. Press (OK) one more time, and then
“OFF” will switch to “ON“. The timer is now set.
Option 2: Shut Off Time (T.off Selection)
a. Press the M button until the “T.off” button is flashing. Press (OK)
to confirm.
b. Follow instructions as illustrated in 1b-1d to set the timer.
Option 3: Cycling Timer (T.I/O Selection)
The third selection, T.I /O, lets you set up the machine to cycle on and off
during a specific time frame. For example, you could set the unit to run
8 hours a day and remain off the other 16 hours.
NOTE: You are selecting on and off periods of time, not set clock times.
c. Select your desired option-
Option 1: “T. on” – Unit will begin running after a selected amount of time
Option 2: “T. off” – Unit will run for designated amount of time and then turn off
Option 3: “T. I/O” – Unit will cycle “on” and “off” based on the set time. If unit is off, the
cycling will start with unit “off”. If unit is on, the cycling will start with the unit “on.”
a. Press the(M) button until the T.I/O selection is flashing. Press the (OK)
button to select.
b. Use the up and down arrows to adjust the hours and minute of the
first cycle.
c. Use the (M )button to move from 1st line of display to the second and
then adjust second time period with up and down arrows.
d. Press the (OK) button to confirm the time. (Flashing OFF will turn to ON).

HumidTi
mer
TempUR
TempU
R
Settin
n
g
OO
ff
oF
℃
-9 -
DEHUMIDIFIERS
d. Press the menu key to move the cursor to the [°C on/off] or [°F off/on] (where your
cursor is will flash)
e. Press the (OK) key to confirm. The on/off status of C and F will exchange.
b. Press the Menu key unit “TempU” flashes. Press (OK) to select.
c. The screen will show: Celsius degree [°C on/off] and Fahrenheit degree
[°F off/on].
This selection allows you to switch the machine from displaying temperature in degrees
Celsius to degrees Fahrenheit.
a. Press the menu key. The screen willl show: Humid, Timer, Tempu, R.
3. Temperature Scale Settings
※Preparing the Unit for Use※
1. Position the machine so there is a minimum of 8” clearance for the back and sides. The
front of the unit should be positioned for maximum discharge distance or directly to a spe-
cific location for spot dry. If the compressor didn’t remain vertical during transportation, wait
a minimum of 30 minutes before turning the unit on.
2. The included drain line attaches to the unit via a quick connection fitting that is located on
the base of the unit. The drain line should be routed to a suitable drain or outside. Since the
unit has an integral drain pump, the drain line may go up vertically (no more than 15’) prior
to reaching the final drain location.
Setup
Quick Connect Fitting
Quick Connection to Drain Tube

-10-
Discharge Ducting Inlet Flex Ducting
Quick Connect Fitting
Quick Connection to Drain Tube
DEHUMIDIFIERS
Optional Duct Installation
Ducting of the unit allows you to condition an adjacent room or focus the discharge to a
specific area. The inlet/return grill is designed for 12” flex duct while the supply grille is
designed for 12” flex duct or layflat ducting.
15’
3. Firmly insert the power cord into the socket on back of the unit near the top.
4. Turn on the dehumidifer and use the control panel to set up the dehumidifier
as desired
1. Maximum Total Duct Run = 20’
2. Maximum run if only ducting inlet or outlet= 12’
3. It may be helpful to remove the grilles from the end caps when connecting flex duct.

※Maintenance and Repair
-11-
DEHUMIDIFIERS
Exterior Cleaning
• Use a soft, slightly damp cloth to wipe the plastic body
• Never spray the exterior directly with water or cleaner
Filter Cleaning
1. To access the filter, rotate the inlet grille counter-clockwise. Remove the filter from
the grille.
※
2. You can clean the filter by vacuuming it or rinsing it with warm water (no soap or
solvents). Always make sure the filter is dry prior to restarting the unit.
3. Place the filter back in the grille. Reinstall the grill by rotating clockwise.
The Elite comes standard with a prefilter and MERV-8 filter, which are washable.
NOTE: The carbon filter and HEPA filter (optional accessories) are NOT washable. Replace as needed.

-12-
Remove the screw and open
the latch (one per side)
DEHUMIDIFIERS
Always unplug unit prior to performing any maintenance
Accessing Internal Components
1. Remove the screws from the side latches (one per side).
WARNING
2. Undo the two latches on the base of the unit by pressing in the safety then opening the
latch.
3. Lift open back housing
Lift open
Squeeze safety and open latch

-13-
Squeeze safety and open latch
Cover
Pump
Access screws for electrical
compartment
DEHUMIDIFIERS
Integral Pump Maintenance
The pump is designed with quick connection construction, making it easy to access the
pump and components for service and maintenance.
NOTE: This pump requires routine maintenance that is not covered by your 1 year parts
warranty. Only a defective pump will be repaired or replaced under the warranty.
As with all pumps, preventative maintenance is necessary to prevent issues from dirt
and slime that may accumulate in the drain system. This includes the drain pan, hose
to the condensate pump, pump reservoir, pump head, float assembly, and discharge
tubing.
At least once per year, clean your pump system.
Basic Pump Cleaning:
1. Press the pump button (P) to drain any water from reservoir.
2. Disconnect power to the dehumidifier.
3. Mix a 16 oz cleaning solution of one of the following: 1 oz bleach / 15 oz water or 4 oz
white vinegar / 12 oz water. Pour the solution into the drain tray at the base of the coils.
NOTE: If you get any cleaning solution on the coils, flush with water.
4. Allow cleaning solution to soak for 15 minutes.
5. Reconnect power to dehumidifier.
6. Pour clean water into reservoir so the pump activates twice (about 16-32 oz. water)
7. Repeat if needed or refer to Advanced instructions.
To Remove Pump from Reservoir:
1. Unplug the unit.
2. Open the back housing as shown on page 12.
3. Remove the condensate tube from the pump.
4. Use the quick connect fittings to disconnect the main power and float switch electrical cables.
5. Use a flathead screw driver to gently pry the the pump off the reservoir.

-14-
DEHUMIDIFIERS
1. a. Use the manual pump button (P), to drain any water from reservoir.
b. Unplug the unit, and remove pump from reservoir (see page 13)
c. Use a wet dry vac or paper towels to remove any remaining water from the
pump reservoir.
2. Fill the pump reservoir with cleaning solution (15 oz water / 1 oz bleach or 12 oz
water / 4 oz white vinegar).
3. Reassemble the pump and use the manual pump button to flush the mixture
through the discharge tubing.
4. Mix another batch of cleaning solution then pour it slowly into drain pan under
evaporator coil and allow it to clean the hose from pan to pump. This process
can be stopped when the pump energizes 1 time.
NOTE: If you get any bleach/water mixture on coils, flush with water.
5. Pour sufficient clean water through the drain pan so that the pump activates
twice (16-32 ounces).
6. Reassemble the unit and return it to operational status.
Advanced Pump Cleaning:
Cleaning the Coils
The coils on your dehumidifier also need to be cleaned once per year. To clean,
simply spray with a self-rinsing, foaming coil cleaner (such as WEB Coil Cleaner).

Troubleshooting
-15-
DEHUMIDIFIERS
※
Storing Your Dehumidifier
※
If you plan on storing your dehumidfier for an extended period of time:
1. Turn unit off and allow to dry.
2. Manually drain pump reservoir.
3. Wrap and secure the power cord .
4. Clean the filter.
5. Store in clean,dry environment.
※ ※
Symptom Cause Solution
Display is Blank
Poor Connection Verify that both ends of the
power cord are plugged in
Power Outage Reset power
No Airflow
Filter is Dirty Clean the filter
Air Inlet or Outlet is Blocked Clear the blockage
Error Code: E1
Humidity Sensor or
Communication Error
Check to ensure that the sensor
wire is connected at both ends.
if no issues are visible, the
sensor may be faulty.
Error Code: E4
Problem with Pump Verify that the pump is properly
installed and functioning. If so,
unplug the unit for two minutes,
then restart.
Error Code: LO
Room Temperature is below
33°F
Increase the room temperature
so it is within operating range
(above 33°F). If error still
displays, check sensor.
Error Code: HI
Room Temperature is above
105°F
Decrease the room temperature
so it is within operating range
(below 105°F). If error still
displays, check the sensor
E5 Error Code Refrigerant Leak Contact Your Installer for
Assistance

-16-
DEHUMIDIFIERS
1. Reset the unit by disconnecting the power cord and then reconnecting it .
NOTE: The unit will not function until the code has been cleared.
2. Manually check to see if pump is operational by pressing the drain button. Verify
that the pump energizes and de-energizes properly. Additionally, check to see if any
water purged from the system.
3. If you haven’t cleaned the system recently, check the discharge line for an obstruc-
tion, then clean the balance of the pump system (see “Maintenance” section for
details).
4. Replace the hoses and/or pump, if maintenance alone isn’t sufficient.
Pump Alarm-Error Code E4
If an E4 code appears on the display:

※※Warranty
-17-
DEHUMIDIFIERS
All warranty benefits apply to the original owner only. Warranty cannot be transferred or assigned.
1 YEAR (FROM DATE OF PURCHASE): Seaira Global warrants the dehumidifier will operate free of defects in workman-
ship and materials. At it’s discretion, Seaira will repair or replace any malfunctioning components, free of charge
(excluding transportation costs)
3 YEARS (FROM DATE OF PURCHASE): Seaira Global warrants the refrigeration circuit (compressor, condenser and
evaporator) will operate free of defects in material or workmanship. At it’s discretion, Seaira will replace defective parts,
including factory labor or refrigerant. This does not include transportation.
5 YEARS (FROM DATE OF PURCHASE): Seaira Global warrants the compressor, condenser, and evaporator will
operate free of any defects in material or workmanship. At it’s discretion, Seaira will repair or replace the defective parts.
This does not include labor, transportation, or refrigerant.
CUSTOMER RESPONSIBILITIES: In order to take advantage of the warranty service, the customer must do the follow-
ing:
1. Customer must provide normal care and maintenance (including, but not limited to cleaning filters, coils and pumps)
2. Removal and re-installation of unit is the sole responsibility of owner.
3. If customer cannot return unit to certified repair center, all costs associated with freight shipment are borne by the
customer. In addition, all duties related to freight shipments, including but not limited to palletizing, wrapping, labeling,
and pickup are associated with customer.
4. If shipped, customer is responsible for all risk of loss or damage.
WARRANTY PROCEDURE:
1. Customer must mail in warranty registration card to Seaira Global. If no card is submitted, warranty period will begin
the day the shipment left the Seaira warehouse. Please be sure to record serial # and date of installation in the spaces
provided on page 2 of the manual. You will need this information to receive an RA number.
2. If warranty service is necessary, customer must contact Seaira Global Tech Support by phone (910-660-0962)to
receive a Return Authorization (RA number).
3. Once an RA has been issued, it is the customer’s job to bring the unit to a certified repair center. If this is not an option,
shipping will be arranged to bring the unit back to the Seaira warehouse (at the expense of the customer).
4. After the unit has been received by Seaira (whether at a repair center or the warehouse), an initial inspection will be
completed, if it is determined to be an invalid warranty claim (see exclusions below), unit will be only be completed after
receiving payment from customer for all associated costs.
5. If unit is defective, the necessary parts will be repaired or replaced and the unit will be available for pickup at certified
repair center or returned via freight shipment (at customer’s expense). Keep in mind that work is only done during normal
working hours. After being repaired, all units are required to go through a rigorous testing process prior to being returned
to customer.
6. Once a part is repaired and the dehumidifier is returned, the original warranty period still applies (no extensions).
Other manuals for Storm Elite
1
Table of contents
Other ALORAIR Dehumidifier manuals

ALORAIR
ALORAIR Storm LGR Extreme User manual

ALORAIR
ALORAIR Sentinel HD90 User manual

ALORAIR
ALORAIR STORM PRO User manual

ALORAIR
ALORAIR Storm Elite User manual

ALORAIR
ALORAIR Storm LGR Extreme User manual

ALORAIR
ALORAIR Storm SLGR 1600X User manual

ALORAIR
ALORAIR ARMORED 170L User manual

ALORAIR
ALORAIR Sentinel HDi90 User manual

ALORAIR
ALORAIR Sentinel HS35 User manual

ALORAIR
ALORAIR Sentinel SLGR 1400X User manual