-8-
Maintenance Instructions
Coil Maintenance
Filter Maintenance
1. Unplug the unit.
2. Slide out the filter.
3. Check the filter for dirt
and buildup.
4. For a Pre-Filter or MERV-8:
Clean the filter mesh by
vacuuming it or washing with warm
water (no soap or cleaners).Gently shake the filter dry,
then reinsert it.
5. For a Carbon, or HEPA Filter:
If there is dirt or buildup, replace filter.
Cleaning the Machine Body
Before Use
• Check the power cord for signs of damage such as fraying. Replace the cord before use if
there is any damage.
• Check the filter for signs of dirt or obstructions. Clean or replace the filter as necessary.
• Check the coils for signs of buildup. Clean if needed.
• Once per year, clean the coils with an approved coil cleaner.
• Coil cleaner should be a self-rinsing, foaming cleaner such as WEB® Coil
Cleaner.
Pump Maintenance
Pump Access:
Remove the screws on the housing, then lift off. Unplug the pump drain line, then remove the
screws holding the pump in place.
Cleaning the Pump Reservoir:
Once the screws are removed, lift off the top of the pump and set aside. Use a paper towel to
wipe out the base of the pump.
Use a soft, damp cloth to clean the exterior of the unit. Do not use any soap or solvents.
1. Remove the screws on the housing.
2. Remove the screws on the air inlet grill and
air outlet grill.
Removing the Housing
DEHUMIDIFIER