1 About these instructions 5
1.1 Validity, storage and forwarding of
the instructions 5
1.2 Symbols 5
2 Safety 5
2.1 Intended use 5
2.2 Safety notes 6
3 Function 7
3.1 Alpha IP app 7
3.2 Downloading the Alpha IP app 7
4 Device overview 8
4.1 Front and back side 8
4.2 Technical data 8
5 Commissioning 9
5.1 Device set-up 9
6 Installation 10
7 Displays 10
7.1 Status displays 10
7.2 Error indications 11
8 Cleaning 11
9 Restoring factory settings 11
10 Radio operation 12
10.1 Transmission limit (duty cycle) 12
Contents
11 Decommissioning 12
12 Disposal 12

5
ENGNORSWE DANFINPOLRUS ENG
1 About these instructions
1.1 Validity, storage and forwarding of the instruc-
tions
1.2 Symbols
The following symbols are used in this manual:
Note:Identifies important or useful information
ÖPreconditions
9Result from an action
• List without fixed order
1., 2. List with fixed order
These instructions apply to the Alpha IP Access Point HAP 21001.
These instructions include information necessary for the commis-
sioning. These instructions must the read completely and thor-
oughly before commencing any work with the device. These in-
structions must be kept and to be handed over to future users.
2 Safety
2.1 Intended use
The Access Point HAP 21001 is a component of the Alpha IP Sys-
tem and serves
• for installation in environments of residential use,
• as a central unit to connect the system to smart phones via
the Alpha IP cloud,
• for the wireless communication in the Alpha IP network.
• for the configuration and operation of the Alpha IP system
and the associated components,
• for the remote access to connected components
Every other use, modification and conversion is expressively for-
bidden. Improper use leads to dangers the manufacturer cannot
be held liable for and will exempt guarantees and liabilities.
Safety
These instructions as well as constantly up-to-date addi-
tional Alpha IP system information can be found under
www.alphaip.de.

6
POL RUSFINDAN SWENORENG
ENG
2.2 Safety notes
All safety notes in these instructions must be observed in order to
avoid accidents with personal damage or property damage. No
liability is assumed for personal damage and property damage
caused by improper use or non-observance of the danger notes.
In such cases any warranty claim is invalid. There is no liability for
consequential damages!
• Only the supplied power supply unit (5 V DC/550 mA) may be
used for the power supply of the device.
• Only use the device if it is in flawless state.
• Only connect the device to a well accessible power outlet.
• Pull the power cord off the power outlet in case of danger.
• Observe the performance limits of the device and its environ-
mental conditions.
• Lay the cables of connected consumers in a way that they do
not lead to dangers (e. g. trip hazards) for persons and pets.
• Only operate the device in a dry and dust-free environment.
• Do not expose the device to the influence of humidity, vibra-
tion, continuous solar radiation or other types of radiation,
coldness or mechanical load.
• Ensure that children do not play with this device or its packag-
ing. Children must be monitored if necessary.
About these instructions

7
ENGNORSWE DANFINPOLRUS ENG
3 Function
The Access Point HAP 21001 is the central system unit of the Al-
pha IP Systems. The HAP 21001 offers cloud-controlled world-
wide access via smart phone app and ensures the software up-to-
dateness via automatic system updates.
Configuration and the operation of the HAP 21001 and of con-
nected Alpha IP components can be performed comfortably and
individually via the Alpha IP app on your smart phone. The pos-
sible function range depends on the used system components.
Communication is performed via the Alpha IP cloud with the
Homematic IP (HmIP) radio protocol. Radio transmission is real-
ised on a non-exclusive transmission path; thus, interference can-
not be completely excluded. Interference can be caused e. g. by
switching processes, electric motors or defective electric applianc-
es. (See page 12, Notes on radio operation)
The range inside buildings can be strongly different from
the range in open air.
Function
3.1 Alpha IP app
The entire Alpha IP system is set up and controlled with the Alpha
IP app. The Alpha IP app allocates connected components to the
rooms. The set-up rooms, components and all information are
displayed in a clearly structured way.
3.2 Downloading the Alpha IP App
The Alpha IP app is available to download free of charge for
Android from version 4.4 and for iOS from version 7. The Alpha
IP app is available in the Google Play Store (for Android smart
phones) and in the App Store (for iPhones).

8
POL RUSFINDAN SWENORENG
ENG
4 Device overview
Device overview
4.1 Front and back side
A
LAN
F
G
B
E
D
C
(A) System key and LED
(B) QR code and device number (SGTIN)
(C) Screw holes
(D) Mains connection
(E) Connection of plug-in power supply
(F) Network cable (scope of delivery)
(G) Plug-in power supply (scope of delivery)
Front side
Back side
4.2 Technical data
Short designation of the device HAP 21001
Supply voltage
Power supply unit, primary
side (input)
Power supply unit, secondary
side (output)
100 V-240 V/50 Hz
5 V DC
Power consumption of plug-in
power supply unit
max. 1.5 W
Power consumption max. 500 mA
Standby power consumption 1.1 W
Protection type IP 20
Ambient temperature 5 to 35 °C
Dimensions (W x H x D) 118 x 104 x 26 mm
Weight 153 g
Radio frequency 868.3 MHz/869.525 MHz
Receiver category SRD category 2
Typical radio range 400 m (in open air)
Duty cycle < 1 % per h/< 10 % per h
Network 10/100 Mbit/s, Auto-MDIX
Guidelines 2014/53/EU Radio installa-
tions
2014/30/EU EMC
2011/65/EU RoHs

9
ENGNORSWE DANFINPOLRUS ENG
5 Commissioning
5.1 Device set-up
1. Download the Alpha IP app and install it on your smart phone.
2. Open the Alpha IP app on your smart phone. The installation
is guided by an installation wizard in the app.
3. Connect the Access Point to the router using the supplied net-
work cable (see page 8 pos. D).
4. Establish the power connection using the supplied plug-in
power supply (see page 8 pos. E).
5. Scan the QR code (see page 8 pos. B) on the back of the Ac-
cess Point.
As an alternative, enter the device number (SGTIN) of the
Access Points manually in the app.
Commissioning
The commissioning of the Alpha IP system is described step by
step in this section. Further Alpha IP devices can be added and
integrated into the Alpha IP System after the commissioning of
the Access Point.
(i) The Alpha IP App is available for iOS and Android for a free
download in the respective app store.
(ii) An Internet connection is necessary for commissioning ans
operation.
6. As soon as the LED in the system key (see page 8 pos. A) lights
continuously in blue, confirm this in the app.
In case of other flashing behaviour, follow the instructions
in the app or see error descriptions in section 7.
9The Access Point will be registered to the server; this may last
several minutes.
7. Press the system key (see page 8 pos. A) after successful regis-
tration for confirmation.
9The teach-in process will be performed.
9The Alpha IP Access Point is ready for operation.

10
POL RUSFINDAN SWENORENG
ENG
6 Installation
The ALPHA IP Access Point must be positioned with a
minimum distance of 50 to your WLAN router.
The Alpha IP Access Point can be positioned on a table or installed
to a wall.
1. For wall installation drill two holes with a diameter of 5 mm
and a distance of 7.5cm.
2. Insert the supplied dowels into the bores.
3. Screw in the supplied screws so that they protrude 4 mm from
the wall.
4. Hang the Alpha IP Access Point onto the screws.
7 Displays
7.1 Status displays
Display Meaning Meaning
Continuous
lighting in
orange
Starting process Let the process finish.
Observe the flashing
behaviour.
Quick flashing
in blue
Connection
establishment to
the server
Wait until the the
process is finished.
Continuous
lighting in blue
Standard opera-
tion, connection
to server OK
Operation can be
continued.
Long lighting in
green
Process confirmed Confirmation of per-
formed set-up.
Alternate long
and short flash-
ing in orange
Updating Wait until the the
process is finished.
InstallationDisplays /

11
ENGNORSWE DANFINPOLRUS ENG
7.2 Error indications
Display Meaning Solution
Quick flashing
in yellow
No connection to
network or router
Connect the Access
Point to the router.
Continuous
lighting in
yellow
No Internet con-
nection
Check the Internet
connection and the
firewall settings.
Quick flashing
in red
Update error Check the server and
Internet connection.
Restart the Access
Point by shortly dis-
connecting it from the
power supply.
Quick flashing
in orange
Preliminary step
for restoring the
factory settings
Press the System key
again for 4 seconds
until the LED lights up
in green.
Long lighting
in red
Reset failed Repeat the process.
Displays/Cleaning/Factory settings
8 Cleaning
Clean the device with a soft, clean, dry, and lint-free cloth. The
cloth may be moistened with lukewarm water for the removal
of heavier contamination. Use a solvent-free cleaning agent for
cleaning.
9 Resetting factory settings
All settings will be lost when the factory settings are restored.
The factory setting of the individual Alpha IP components must
also be restored.
1. Disconnect the Access Point from the power supply. Pull the
mains plug for this.
2. Connect the base station again to the power supply and press
the System key simultaneously for 4 seconds until the LED
flashes rapidly in orange.
3. Release the System key.
4. Press the System key again for 4 seconds until the LED lights
up in green.
5. Release the System key again.
9The device restarts.
The factory settings are reset.

12
POL RUSFINDAN SWENORENG
ENG
10 Radio operation
Radio transmission is realised on a non-exclusive transmission
path; thus, interference cannot be completely excluded. Other
interference can be caused e. g. by switching processes, electric
motors or defective electric appliances. The range inside buildings
can be strongly different from the range in open air. Apart from
the transmission power and the reception characteristics of the
receivers, environmental aspects as e. g. humidity as well as the
constructional structure are important factors for this. The Alpha
IP system components correspond to the basic requirements and
the other relevant rules of the Directive 2014/53/EU Radio Equip-
ment. The complete Declaration of Conformity can be found un-
der www.alphaip.de.
10.1 Transmission limit (duty cycle)
The duty cycle is a legally regulated limitation of the transmission
time of devices in the 868 MHz range. The maximum transmission
time of a device is 1 % per hour (i. e. 36 seconds). When this time
has elapsed, the device must not send anything until the time limi-
tation is over. This may happen in individual cases, e. g. during the
commissioning of a system due to radio-intensive teach-in pro-
cesses. Exceeding the duty cycle can lead to temporarily missing
functions. The function of the device is completely restored after
one hour as a maximum.
Radio operation
11 Decommissioning
1. Reset the device to factory settings.
2. Loosen all connected cables.
3. Uninstall the device and dispose of properly.
12 Disposal
Do not dispose of the device with domestic waste! Elec-
tronic devices/products must be disposed of according to
the Directive for Waste Electrical and Electronic Equipment
at the local collection points for waste electronic equip-
ment.

13
ENGNORSWE DANFINPOLRUS ENG
This manual is protected by copyright. All rights reserved. It may
not be copied, reproduced, abbreviated or transmitted, neither
in whole nor in parts, in any form, neither mechanically nor elec-
tronically, without the previous consent of the man-
ufacturer. © 2016
132141.1628

14
POL RUSFINDAN SWENORENG DAN NOR
DA
DAN 4
1 Om denne vejledning 15
1.1 Gyldighed, opbevaring og videregivelse af vejled-
ningen 15
1.2 Symboler 15
2 Sikkerhed 15
2.1 Bestemmelsesmæssig brug 15
2.2 Sikkerhedshenvisninger 16
3 Funktion 17
3.1 Alpha IP app 17
3.2 Download af Alpha IP app 17
4 Oversigt over enheden 18
4.1 For- og bagside 18
4,2 Tekniske data 18
5 Ibrugtagning 19
5.1 Indstilling af enheden 19
6 Montering 20
7 Visninger 20
7.1 Statusvisninger 20
7.2 Fejlvisninger 21
8 Rengøring 21
9 Genetablering af fabriksindstillinger 21
10 Radio-drift 22
10.1 Sendelimit (Duty Cycle) 22
Indhold
11 Ud-af-drifttagning 22
12 Bortskaffelse 22

15
ENGNORSWE DANFINPOLRUS DANNOR
1 Om denne vejledning
1.1 Gyldighed, opbevaring og videregivelse af vejled-
ningen
1.2 Symboler
Følgende symboler bruges i denne vejledning:
Henvisning: Kendetegner en vigtig eller nyttig infor-
mation
ÖForudsætning
9Resultatet, som fremkommer af en handling
• Optælling uden fast rækkefølge
1., 2. Anvisning med fast rækkefølge
Denne vejledning gælder for Alpha IP Access Point HAP 21001.
Vejledningen indeholder informationer, som er nødvendige til
ibrugtagning. Inden der arbejdes med enheden, skal nærværende
vejledning læses fuldstændigt og grundigt. Vejledningen skal op-
bevares og videregives til efterfølgende brugere.
2 Sikkerhed
2.1 Bestemmelsesmæssig brug
Access Point HAP 21001 er en del af Alpha IP systemet og tjener
til
• installering i boliglignende omgivelser,
•som central enhed til at forbinde systemet med smartphones
via Alpha IP Cloud,
• trådløs kommunikation i Alpha IP netværket,
•konfiguration og betjening af Alpha IP systemet og de dertil
hørende komponenter,
• teleadgang til forbundne komponenter.
Enhver anden brug, ændringer og ombygninger er udtrykkeligt
forbudte. En ikke bestemmelsesmæssig brug medfører farer, som
producenten ikke hæfter for, samt til garantiudelukkelse og an-
svarsfrihed.
Sikkerhed
Aktuelle udgaver af vejledningen/yderligere Alpha IP sy-
steminformationer findes altid på www.alphaip.de.

16
POL RUSFINDAN SWENORENG DAN NOR
2.2 Sikkerhedshenvisninger
For at undgå ulykker med personskade og materiel skade skal alle
sikkerhedsinformationer i nærværende vejledning overholdes. Der
hæftes ikke for personskade og materiel skade, som forårsages
af ukorrekt brug eller manglende overholdelse af farehenvisnin-
gerne. I sådanne tilfælde bortfalder garantien! Der hæftes ikke
for følgeskader!
• Til strømforsyning af enheden må man kun bruge den levere-
de netdel (5 V DC/550 mA).
• Enheden må kun bruges i teknisk upåklagelig tilstand.
• Enheden må kun tilsluttes til en let tilgængelig stikdåse.
• Ved fare skal enheden trækkes ud af stikdåsen.
• Overhold enhedens effektgrænser og omgivelsesbetingelser.
• Kablet fra tilsluttede forbrugere skal lægges således,
at de ikke kan medføre farer for mennesker og husdyr
(f.eks. snublesteder).
• Brug kun enheden i tørre samt støvfrie omgivelser.
• Enheden må ikke udsættes for påvirkninger fra fugtighed,
vibrationer, konstant sol- eller anden varmeindstråling, kulde
eller mekaniske belastninger.
• Kontroller, at børn ikke leger med produktet eller emballagen.
Hold i givet fald børn under opsyn.
Om denne vejledning

17
ENGNORSWE DANFINPOLRUS DANNOR
3 Funktion
Access Point (HAP 21001) Alpha IP systemets centrale systemen-
hed. HAP 21001 giver cloudstyret verdensomspændende adgang
pr. smartphone app og garanterer en aktuel software via automa-
tiske systemaktualiseringer.
HAP 21001 eller forbundne Alpha IP komponenter kan konfigure-
res og betjenes bekvemt og individuel pr. smartphone via Alpha IP
app. Det mulige funktionsomfang defineres i afhængighed af de
benyttede systemkomponenter.
Kommunikationen foregår via Alpha IP Cloud med den trådløse
Homematic IP (HmIP) protokol. Den trådløse overførsel realiseres
på en ikke eksklusiv transmissionsvej, hvorfor forstyrrelser ikke
kan udelukkes. Forstyrrende påvirkninger kan f.eks. fremkaldes af
koblingsprocesser, elmotorer eller defekte elektriske enheder. (jf.
side 22, Henvisninger om trådløs drift)
Rækkevidden i bygninger kan afvige kraftigt af rækkevid-
den udendørs (lydfelt).
Funktion
3.1 Alpha IP app
Hele Alpha IP systemet indstilles og styres via Alpha IP app. For-
bundne komponenter tilordnes rummene med Alpha IP app'en.
De indrettede rum, komponenter og alle informationer vises over-
skueligt.
3.2 Download af Alpha IP app'en
Alpha IP app'en står gratis til rådighed til at downloade både for
Android fra version 4.4 og for iOS fra version 7. Alpha IP app'en
kan leveres i Google Play Store (for Android-smartphones) og i
App Store (for iPhones).

18
POL RUSFINDAN SWENORENG DAN NOR
4 Oversigt over enheden
Oversigt over enheden
4.1 For- og bagside
A
LAN
F
G
B
E
D
C
(A) Systemtast og LED
(B) QR-kode og enhedens nummer (SGTIN)
(C) Skruehuller
(D) Netværkstilslutning
(E) Tilslutning stiknetdel
(F) Netværkskabel (leveringsomfang)
(G) Stiknetdel (leveringsomfang)
Forside
Bagside
4.2 Tekniske data
Kort betegnelse af enheden HAP 21001
Forsyningsspænding
Netdel primær (indgang)
Netdel sekundær (udsgang)
100 V-240 V/50 Hz
5 V DC
Stiknetdelens effektforbrug 1,5 W maks.
Strømforbrug 500 mA maks.
Effektforbrug i hviledrift 1,1W
Kapslingsklasse IP 20
Omgivelsestemperatur 5 til 35 °C
Mål (B x H x D) 118 x 104 x 26 mm
Vægt 153 g
Radiofrekvens 868,3 MHz/869,525 MHz
Modtagerkategori SRD category 2
Typ. Trådløs rækkevidde 400 m (i lydfelt)
Duty cycle < 1 % pr. h/< 10 % pr. h
Netværk 10/100 MBit/s, Auto-MDIX
Direktiver 2014/53/EU Radioudstyr
2014/30/EU EMC
2011/65/EU RoHs

19
ENGNORSWE DANFINPOLRUS DANNOR
5 Ibrugtagning
5.1 Indstilling af enheden
1. Download Alpha IP app'en og installer den på din smartp-
hone.
2. Åbn Alpha IP app'en på din smartphone. En assistent i app'en
guider gennem installeringen.
3. Forbind Access Point med routeren via det leverede netværks
(jf. side 18 nr. D).
4. Etablér spændingsforsyningen via den vedlagte stiknetdel (jf.
side 18 nr. E).
5. Scan QR-koden (jf. side 18 nr. B) på bagsiden af Access Points.
Alternativt indlæses Access Points enhedsnummer (SGT-
IN) manuelt i app'en.
Ibrugtagning
I dette kapitel er ibrugtagningen af Alpha IP systemet beskrevet
trin for trin. Når Access Point er taget i brug, kan der tilføjes yder-
ligere Alpha IP enheder og integreres i Alpha IP systemet.
(i) Alpha IP app'en står til rådighed for iOS og Android og kan
downloades gratis i den tilsvarende App-Store.
(ii) Til ibrugtagningen og driften kræves det, at der består en
internetforbindelse.
6. Så snart LED'en i systemtasten (jf. side 18 nr. A) konstant lyser
blåt, bekræftes dette i app'en.
Ved en anden blinkreaktion følges anvisningerne i app'en
eller fejlbeskrivelsen i kapitel 7.
9Access Point bliver registreret på serveren, det kan vare nogle
minutter.
7. Efter vel gennemført registrering trykkes systemtasten (jf. side
18 nr. A) som bekræftelse.
9Instruktionsprocessen gennemføres.
9Alpha IP Access Point er parat.

20
POL RUSFINDAN SWENORENG DAN NOR
6 Montering
ALPHA IP Access Point skal anbringes mindst 50 cm fra
din WLAN router.
Alpha IP Access Point anbringes på et bord eller monteres på væg-
gen.
1. Til montering på væggen laves to 5 mm-boringer med en af-
stand på 7,5 cm.
2. Indsæt de medleverede rawplugs i borehullerne.
3. De medleverede skruer skrues så langt ind, at de rager 4 mm
ud af væggen.
4. Hæng Alpha IP Access Point på skruerne.
7 Visninger
7.1 Statuslamper
Display Betydning Betydning
Konstant oran-
gefarvet lys
Startproces Afvent proceduren.
Iagttag blinkreakti-
onen.
Hurtigt blåt
blink
Opbygning af
forbindelsen til
serveren
Vent, til processen er
afsluttet.
Konstant blåt
lys
Standarddrift,
der er forbindelse
med serveren
Der kan fortsættes
med betjeningen.
Langt, grønt lys Proces bekræftet Bekræftelse af den
udførte indstilling.
Skiftevis langt
og kort orange-
farvet blink
En aktualisering
gennemføres
Vent, til processen er
afsluttet.
Montering/Visninger
Other manuals for HAP 21001
2
Table of contents
Languages:
Other Alpha IP Wireless Access Point manuals
Popular Wireless Access Point manuals by other brands

D-Link
D-Link DWL-8220AP - AirPremier Wireless Switch Dualband Access... manual

Siemens
Siemens SCALANCE W700 Reference manual

Cisco
Cisco aironet 1810 series user guide

Dell
Dell TrueMobile 4350 user guide

NETGEAR
NETGEAR WG302v2 - ProSafe 802.11g Wireless Access... Reference manual

D-Link
D-Link DAP-1160 Quick install guide