alpro AS626S User manual

Waterproof Keypad
AS626S
Read all instructions before starting installation
Connect keypad using wiring description.
Wiring description
Power 12 or 24v AC or DC
(AC does not have a polarity)
Brown + Positive
Blue - Negative
Output Relay Max 2amp @ 24v
Grey Common
Red Selectable – Relay NO or NC (Default is set to NO)
To change see 7 & 8 under ‘Programming the Keypad’
Contact 2 Amp. Dry contact for Door Strike
Exit Button Push to make – Volt free
White/Pink Exit Button (NO)
Power Consumption Stand by – Approximately 25 milliamps @12vDC
Operation – Approximately 80 milliamps @12vDC
For 12vDC inductive loads such as electric strikes and electromagnetic locks,
the enclosed 12vDC metal oxide varistor must be connected in parallel with
the load, at the load terminals and not in the keypad.
Ensure power supply is of correct rating, taking into account the current
requirements of the locking items and accessories.
Do not insert security plugs into fixing holes until all installation and testing has
been completed. These items require drilling out and cannot be re-fitted.
LED signalling explanation
GREEN LED Door Strike activated (unlocked)
RED LED Normal Operation: 3 sec. ON = wrong
Code Entry
Slow flashing = wrong code
entry 3 times
Programming Mode: Fast flashing = programming
different functions
Slow flashing = programming
stand-by
Very fast flashing = erasing all
user codes
The door remote opening (via exit switch) is possible when a dry contact is
made between the wires White and Orange.
The lock is activated for the time the system is programmed. Factory set @
5 seconds.
Remote opening is disabled during programming and latch mode.
Apply power to the keypad. The keypad’s buzzer will sound briefly, the
Red LED will illuminate briefly Initialisation is now complete, with a default
master code of 1-2-3-4 and a 5-second open door.
PACK CONTENTS
MOUNTING INSTRUCTIONS
ACTIVATION
TESTING THE UNIT
PROGRAMMING THE KEYPAD
TROUBLE SHOOTING
INITIALISATION
Connect to + of
Locking Device
Connect to - of
Locking Device
Breakglass
Pink
White
Brown
Blue
Grey
Red
Power Supply
Exit Button
Enter the master code [1 2 3 4 #]
The Door Relay changes its contacts for 5 sec.
The Green LED will light up for 5 sec. Repeat this step 2,3 times.
If the master code is wrongly typed in, the Red LED lights up for 3 sec. re-
enter the Code as soon as the LED goes OFF.
IMPORTANT: CHANGE THE FACTORY SET MASTER CODE WHEN YOU PROGRAM
YOUR UNIT FOR USE. THERE IS NO WAY TO RECOVER THE NEW MASTER CODE IF
IT IS LOST OR FORGOTTEN. THE UNIT CAN BE RESET TO FACTORY PRESETS AND
CUSTOMISED AGAIN. See Data Reset
Enter H H1 2 3 4 H H
The keypad enters programming mode, the Red LED flashes
If no further information is added, the unit will revert to normal
operation after a 3 second delay. To exit programming press #.
There are six programming options: -
1. Set new master code
It is suggested the Master Code is not changed until person
programming is familiar with all aspects of programming the keypad!
2. Set new user code
3. Erase a user code
4. Erase all user codes
5. Set door open time (1-99s)
6. Set output to latch option
Continued over...
The keypad does not “respond” when activating the keys.
1. Make sure the electronic unit has been properly wired to the PSU and the
power has not been cut-off.
The keypad “responds” but the door does not open.
1. Make sure the Green LED is illuminated.
2. If not, the entered code has not been programmed yet. Please refer to
“Programming”.
3. Enter the Master Code and make sure the door opens correctly. If not,
check the wiring and the Lock’s integrity.
1
3
5
7
9
*
2
4
6
8
0
#
x2x2

Waterproof Keypad
AS626S
Read all instructions before starting installation
To set new master code
TAKE TIME TO ALLOW EACH BUTTON INPUT / LED TO REGISTER
Enter H H 1 2 3 4 H H The keypad enters programming mode,
the Red LED flashes
Enter 2 The Red LED illuminates for 2 seconds and
then flashes
Enter 0-0-0# The Red LED illuminates for 2 seconds and
then flashes
Enter new 4-8 digit code This is the new master code, record the
number and keep it safe
Enter # The Red LED illuminates for 2 seconds and
then flashes
Re-enter the new master code The Red LED illuminates for 2 seconds and
then flashes
Enter #
Enter # To exit programming mode
To set a new master code of 112233
Enter H H master code H H 2 000# 112233# 112233# #
To set a new user code
Enter H H master code H H The keypad enters programming mode,
the Red LED flashes
Enter 2 The Red LED illuminates for 2 seconds and
then flashes
Enter address of new user code i.e. 001 (001-200 accepted)
Enter # The Red LED illuminates for 2 seconds and
then flashes
Enter new 4-8 digit user code This is the new user code, record the
number and keep it safe
Enter # The Red LED illuminates for 2 seconds and
then flashes
Re-enter
the new 4-8 digit user code
The Red LED illuminates for 2 seconds and
then flashes
Enter # The new code is added, to add new codes
continue from second step, changing the
address each time. When finished enter an
additional # to exit programming mode.
Re-Enter 2 to set the next code or # to EXIT
To set a new user code of 6626 in address 1
Enter H H master code H H 2 001# 6626# 6626# #
To set a new user code of 6626 in address 1 & 7788 in address 2
Enter H H master code H H 2 001# 6626# 6626# 2 002# 7788# 7788# #
To remove an individual user code - Only the user code addresses are
removable, the master code may be changed but not removed
Enter H H master code H H The keypad enters programming mode,
the Red LED flashes
Enter 3 The Red LED illuminates for 2 seconds and
then flashes
Enter address of user code to
be removed Example 001 (001-200 accepted)
Enter # The red LED illuminates for 2 seconds and
then flashes (Address accepted)
Enter address of user code to
be removed Example 001 (001-200 accepted)
Enter # The red LED illuminates for 2 seconds and
then flashes the code is removed
Enter # Exit programming mode
To remove all user codes
Enter H H master code H H The keypad enters programming mode,
the red LED flashes
Enter 4 The Red LED illuminates for 2 seconds and
then flashes
Enter master code
Enter # The Red LED illuminates for 2 seconds and
then flashes 40 sec. All user code addresses
are removed
Enter # For exit programming
To set lock open time
Enter H H master code H H The keypad enters programming mode,
the Red LED flashes
Enter 1 The Red LED illuminates for 2 seconds and
then flashes
Enter door open time (01-99) Ex. 05 = 5 seconds
Enter # The Red LED illuminates for 2 seconds and
then flashes
Enter # For exit programming
To set the door open time to 10 seconds
Enter H H master code H H 1 10 # #
To set output relay to latching mode (On-Off)
Enter H H master code H H The keypad enters programming mode,
the Red LED flashes
Enter 1 The Red LED illuminates for 2 seconds and
then flashes
Enter 00
Enter # The Red LED illuminates for 2 seconds and
then flashes
Enter # The relay is set to latching mode
TO PROGRAM THE RELAY FOR A TIMED FUNCTIONING PLEASE PERFORM
PROCEDURE 5.
To set Normally Open
Enter H H master codeH H The keypad enters programming mode,
the Red LED flashes
Enter 6 The red LED illuminates for 2 seconds and
then flashes
Enter 0
Enter # The Red LED illuminates for 2 seconds then
flashes
Enter # Exit the programming mode
To set Normally Closed
Enter H H master code H H The keypad enters programming mode,
the Red LED flashes
Enter 6 The red LED illuminates for 2 seconds and
then flashes
Enter 1
Enter # The Red LED illuminates for 2 seconds then
flashes
Enter # Exit the programming mode
OPERATING THE KEYPAD
Enter user code # The relay operates and Green LED
illuminates
If three incorrect attempts are made to enter a user code, the keypad will lock
out for thirty seconds
DATA RESET
There are two basic models out in the field. Before attempting Data Reset identify
the model concerned. Dependent on model select correct reset instructions.
In the event that programming administration is lost, or errors have been made
in the programming, it is possible to set the keypad master back to the factory
default:
Version 1
Power off to keypad - wait 5 seconds - reapply power to Keypad
When power reapplied - if Red LED stays on for 1 second = Version 1
If the unit has been fitted with, this process will destroy the anti-tamper plugs
Remove anit-tamper plugs and the keypad from the wall
Press the reset button on the rear of keypad
The red LED illuminates for 2 seconds and then flashes
Enter 1234# The red LED illuminates for 2 seconds and a
continuous tone is heard
Press the reset button on the rear of keypad
Enter # The red LED illuminates for 2 seconds and
then flashes
Enter # The relay is set to open the door for 5
seconds
Master code 1-2-3-4
User code 5-6-7-8-9-0
Version 2
Power off to keypad - wait 5 seconds - reapply power to Keypad
When power reapplied - if Red LED stays on for 3 seconds = Version 2
Power up the unit During the first 3 seconds the Red LED is ON
Enter
**1234# Green LED will appear then turn to Red LED
The unit will sound 3 times and the data will
be restored as follows
Master code 1-2-3-4
User code 5-6-7-8-9-0 Please erase this code at address 200
Door open time 5 seconds
Warranty
This product is guaranteed for a period of 5 years against defects in manufacture,
workmanship or materials provided that all electrical and mechanical installation
requirements are adhered to as per this instruction sheet. All third party and
consequential claims are expressly excluded from this warranty.
16
3
4
5
7
8
2
PROGRAMMING THE KEYPAD CONTINUED..
Table of contents
Other alpro Keypad manuals
Popular Keypad manuals by other brands

Simons Voss Technologies
Simons Voss Technologies PIN code keypad MobileKey quick guide

AMC
AMC K-LCDW800 installation manual

Beijing lanchuan
Beijing lanchuan KPID-9808 Operation guide

Assa Abloy
Assa Abloy Yale SR-PB Installation

Interlogix
Interlogix NX-182xx NetworX User reference guide

Digiplex
Digiplex EVO641 user guide