T3KAK33F16
16 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove3 enclosure with TKA3 Altronix/Keyscan backplane
- (2) eFlow6NB - Power Supply/Chargers
- (2) ACM8 - Fused Access Power Controllers
- (1) PD4UL - Fused Power Distribution Board
- (1) T16175 Transformer (packed separately)
Access & Power Integration
Rev. T3KAK33F16_112119
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
All registered trademarks are property of their respective owners. More than just power.™
Installation Guide
All components of this Trove kit are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
- 2 - T3KAK33F16
Overview:
Altronix T3KAK33F16 Trove Keyscan kit is pre-assembled and consist of Trove3KA3 enclosure/backplane with factory installed Altronix
power supply/chargers, transformer, and sub-assemblies. This kit also accommodates various combinations of Keyscan boards for up to
sixteen (16) doors in a single enclosure.
Configuration Chart:
Altronix
Model
Number
120VAC
60Hz
Input
Current
(A)
Power
Supply
Boards
Input
Fuse
Rating
Power
Supply
Boards
Battery
Fuse
Rating
Nominal DC
Output Voltage Maximum Supply
Current for Main
and Aux. Outputs
on each Power
Supply board
and each ACM8
Access Power
Controller’s outputs
Fail-Safe/
Fail-Secure
or Dry Form
“C” Outputs
Current Per
ACM8
Output (A)
ACM8
Board
Input
Fuse
Rating
ACM8
Board
Output
Fuse
Rating
PD4UL
Board
Output
Fuse
Rating
[DC] [Aux]
24VDC
Output
Range (V)
24VDC
Output
Range (V)
T3KAK33F16 7.0 5A/
250V
10A/
32V 20.19-26.4 20.19-26.4 24VDC @ 5.8A 16 2.5 10A/
250V
3.5A/
250V
3.5A/
250V
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws
in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three
upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure.
Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the three
upper screws. Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired
location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure
approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the
Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mounting Included T16175 Transformer:
To prevent damage, T16175 is packed separately and needs to be installed by the user.
It is to be mounted on the left of the backplane, next to PD4UL power distribution board.
Please follow the steps below:
a. Orient T16175 so the terminals are facing down (Fig. 4, 4a, pg. 3).
b. Put T16175’s upper mounting holes over two mounting pems on backplane and secure with
two (2) lock nuts (Fig. 4, 4a, pg. 3).
c. Use included mounting bracket to secure T16175’s lower mounting holes. Align pems on the
bracket with T16175’s lower mounting holes and corresponding holes in the backplane.
Push the bracket’s pems through the holes and secure from the back side of the backplane
with two (2) lock nuts (Fig. 2, pg. 2).
d. Connect AC power 115VAC, 50/60Hz to primary leads (black and white) from
terminal numbers 1 and 2 (Fig. 3, pg. 2).
e. Measure output voltage across the secondary leads (yellow and blue) from
terminal numbers 7 and 12 (Fig. 3, pg. 2) before connecting devices.
This helps avoiding potential damage.
f. Connect PD4UL (factory mounted) to the secondary leads (yellow and blue) from
terminal numbers 7 and 12 (Fig. 3, pg. 2).
5. Mount Keyscan boards to backplane, refer to page 3.
6. Refer to the eFlow Power Supply/Charger Installation Guide (for eFlow6NB), ACM8/CB Installation Guide for ACM8,
and T16175 Installation Guide for T16175 for further installation instructions.
Fig. 1
Fig. 2
Fig. 3 - T16175 Wiring Configuration
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
TKA3
Lock Nut
Mounting
Hole
Mounting Bracket
Terminals
T16175
16VAC (Secondary) Output115VAC (Primary) Input
4 356 2 1 10 91112 8 7
T3KAK33F16 - 3 -
NC C NO NC C NO
ACFAIL BATFAIL
TRIGGER
AC DCAC1
EOLNOGND
SUPERVISED RESET
+AUX-
- BAT +-DC +
L G N
OFF - 24V
ON - 12V
ON
Altronix
eFlow6NB
NC C NO NC C NO
ACFAIL BATFAIL
TRIGGER
AC DCAC1
EOL NO GND
SUPERVISED RESET
+AUX-
- BAT +-DC +
L G N
OFF - 24V
ON - 12V
ON
Altronix
eFlow6NB
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4 5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
TRG
FACP
1 2 3 4
1 2 3 4
ON
ON
1 2 3 4
1 2 3 4
ON
ON
Altronix
ACM8
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4 5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
TRG
FACP
1 2 3 4
1 2 3 4
ON
ON
1 2 3 4
1 2 3 4
ON
ON
Altronix
ACM8
Altronix PD4UL
Altronix
T16175
(packed separately)
F1 F2 F3 F4
1P 1N 2P 2N 3P 3N 4P 4N
P N
Keyscan
CA250B,
CA4500B
CA8500B
Keyscan
CA250B,
CA4500B
CA8500B
Keyscan
DPS15 Locknut
Keyscan
DPS15 Locknut
Keyscan
OCB8
Keyscan
OCB8
Keyscan
CIM
Keyscan
CIM
Keyscan
OCB8
Keyscan
OCB8
T3KAK33F16: Configuration of Keyscan Boards
1. Mount appropriate Keyscan boards into the correct positions (Fig. 4, pg. 3) by postioning standoffs over appropriate holes in the
backplane and depressing down on board to secure standoff to the backplane (Fig. 4b, pg. 3).
2. Fasten backplane to Trove2 enclosure utilizing pan head screws (provided).
Fig. 4
Plastic Standoff
pre-mounted into
Keyscan modules
Insert into
TKA2 or
TKA3 backplane
Altronix
T16175
Terminals
Lock Nuts
Bracket
Fig. 4b
Fig. 4a
- 4 - T3KAK33F16
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: [email protected] | Lifetime Warranty | Made in U.S.A.
IIT3KAK33F16 K21S MEMBER
Enclosure Dimensions (H x W x D approximate):
36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm)
G
G
2.00”
(50.8mm)
8.75”
(222.3mm)
8.75”
(222.3mm)
8.62”
(219mm)
7.06”
(179.3mm)
1.25”
(31.8mm)
1.25”
(31.8mm)
2.00”
(50.8mm)
7.12”
(222.25mm)
9.5”
(241.3mm)
30.12”
(768.1mm)
14.01”
(355.9mm)
14.01”
(355.9mm)
9.5”
(241.3mm)
1.25”
(31.75mm) 1.55”
(39.37mm)
1.78”
(45.21mm)
1.25”
(31.8mm)
1.07”
(27.2mm)
1.10”
(27.9mm)
2.00”
(50.8mm)
10.75”
(273.1mm)
10.75”
(273.1mm)
10.62”
(269.8mm)
2.00”
(50.8mm)
10.75”
(273.1mm)
10.75”
(273.1mm)
10.62”
(269.8mm)
36.12”
(917.5mm)
33.63”
(854.20mm)

Other Altronix IP Access Controllers manuals

Altronix ACMCBJ Series User manual

Altronix

Altronix ACMCBJ Series User manual

Altronix TROVE PLUS T2M7XK1V User manual

Altronix

Altronix TROVE PLUS T2M7XK1V User manual

Altronix Trove Series User manual

Altronix

Altronix Trove Series User manual

Altronix TROVE plus T2M7XK1 User manual

Altronix

Altronix TROVE plus T2M7XK1 User manual

Altronix Maximal series User manual

Altronix

Altronix Maximal series User manual

Altronix Trove T1VK3F4 User manual

Altronix

Altronix Trove T1VK3F4 User manual

Altronix TROVE T1CVK34 User manual

Altronix

Altronix TROVE T1CVK34 User manual

Altronix Maximal3FV User manual

Altronix

Altronix Maximal3FV User manual

Altronix acm8 User manual

Altronix

Altronix acm8 User manual

Altronix Maximal11FD User manual

Altronix

Altronix Maximal11FD User manual

Altronix Trove THWD2 User manual

Altronix

Altronix Trove THWD2 User manual

Altronix Trove T2KHK3F12 User manual

Altronix

Altronix Trove T2KHK3F12 User manual

Altronix eFlowNA8V Series User manual

Altronix

Altronix eFlowNA8V Series User manual

Altronix TROVE Mercury Series T3MK75F16 User manual

Altronix

Altronix TROVE Mercury Series T3MK75F16 User manual

Altronix ACMCB Series User manual

Altronix

Altronix ACMCB Series User manual

Altronix Trove T2SSK7F8 User manual

Altronix

Altronix Trove T2SSK7F8 User manual

Altronix M Series User manual

Altronix

Altronix M Series User manual

Altronix TROVE T2SSK7F8D User manual

Altronix

Altronix TROVE T2SSK7F8D User manual

Popular IP Access Controllers manuals by other brands

Moxa Technologies WAC-2004A Quick installation guide

Moxa Technologies

Moxa Technologies WAC-2004A Quick installation guide

Rockwell Automation Allen-Bradley Guardmaster 442G MABH Series user manual

Rockwell Automation

Rockwell Automation Allen-Bradley Guardmaster 442G MABH Series user manual

Ubiquiti Rocket Prism 5AC GEN2 quick start guide

Ubiquiti

Ubiquiti Rocket Prism 5AC GEN2 quick start guide

ITS Telecom EKSELANS CCA installation manual

ITS Telecom

ITS Telecom EKSELANS CCA installation manual

CDVI KCPROXWLC installation manual

CDVI

CDVI KCPROXWLC installation manual

Commax IDentry T20 Quick manual

Commax

Commax IDentry T20 Quick manual

Detex ES500 Series instructions

Detex

Detex ES500 Series instructions

KEYKING FPC1000 Series user manual

KEYKING

KEYKING FPC1000 Series user manual

Security Brands Ascent 16-X2 quick start guide

Security Brands

Security Brands Ascent 16-X2 quick start guide

Wasp B2000 user manual

Wasp

Wasp B2000 user manual

Homematic IP HmIP-SK14 operating manual

Homematic IP

Homematic IP HmIP-SK14 operating manual

Soyal AR-331-E manual

Soyal

Soyal AR-331-E manual

CrucialTrak Bacs Duo Installation & user guide

CrucialTrak

CrucialTrak Bacs Duo Installation & user guide

Videx PORTAL PLUS Application note

Videx

Videx PORTAL PLUS Application note

ZKTeco ProCapture-T user manual

ZKTeco

ZKTeco ProCapture-T user manual

ZKTeco LF10 quick start guide

ZKTeco

ZKTeco LF10 quick start guide

eSSL X7 user manual

eSSL

eSSL X7 user manual

ACT ACTsmart2 Series Operating and installation instructions

ACT

ACT ACTsmart2 Series Operating and installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.