1. Specifications
Frequency: 433.92 MHz
Operating Temperature: 32°-120°F (0°-49°C)
Operating Humidity: 5-95% RH non-condensing
Battery: 1x CR123A Panasonic Lithium 3V DC
Battery Life: 5 Years
Compatibility: Connect+ Encrypted
Pet Immunity: Up to a maximum of 85 lbs
Supervisory Interval: Approximately 60 minutes
Coverage Area: 40 feet by 40 feet, 90° angle
Light Immunity: 2000 Lux
Coverage Pattern:
Side View:
Top View:
2. Package Contents
1x Sensor 1x Sensitivity Jumper
4x Screws & Wall Anchor 1x CR123A battery (installed)
2x Sensor Case Screw 1x Back Mounting 2-Sided Adhesive Tape
1x Manual 2x Side Mounting 2-Sided Adhesive Tape
3. Component Identification
4. Enrollment:
To enroll the motion sensor, set your panel into programming mode according
to the panel manufacturer’s instruction. When prompted by the panel, enter
the 6-digit serial number printed on the sensor label.
Some panels can enroll your sensor by capturing the serial number
transmitted by your sensor. The sensor can be enrolled in the panel or
recognized by the DSC wireless device programmer device by triggering
wireless transmissions. The red LED will begin to flash for 45 seconds. When
the LED stops flashing, the sensor can be triggered by waving your hand in
front of the motion sensor. The sensor will transmit every time motion is
detected. Trigger the motion sensor as many times as necessary until the
panel recognizes the sensor’s serial number.
5. Mounting
Mount the motion sensor at 7.5 feet (2.3
meters) above the floor. Press the case release
button to separate the front and back sensor
case. The back case gives access to both the
flush mount and corner mount screw knock
outs. Remove the appropriate knockouts and
use the included screws to mount in the
desired mounting location. It is recommended
to ensure there is a tight seal around the
knockouts to prevent bugs from entering the
sensor and causing false alarms. Replace the
front sensor cover to snap shut and screw in
the sensor case screws on the top and bottom
of the back sensor case. The RE611P is intended to be installed in
accordance with the Standard for Installation and Classification of
Residential Burglar Alarm Systems, UL1641 & UL 691 - Classification of
Burglar and Holdup Alarm Systems, UL 681, and is it intended for
Residential use only. The RE611P intrusion detection unit shall be installed
in accordance with the Standard for Installation and Classification of
Residential Burglar Alarm Systems, CAN/ULC-S310 and CSA C22.1,
Canadian Electrical Code, Part I, Safety Standard for Electrical Installations.
6. Sensitivity Jumper Settings
For standard sensitivity motion detection with pet immunity leave the jumper
in the default setting (on). Remove the jumper if increased sensitivity to
movement is desired.
7. Walk Test Mode
Walk test mode can be used to test the motion sensor detection coverage
area. To enter walk-test mode remove the battery for 10 seconds and
re-insert the battery. The red LED will begin to flash indicating that the motion
sensor is warming up. After 45 seconds, the LED will stop flashing which
indicates the motion sensor is ready to detect motion. The LED will illuminate
each time motion is detected. Once the LED goes out, the sensor is ready to
detect motion again. Walk test mode ends after 15 minutes. It is
recommended that the RE611P PIR is tested monthly to ensure proper
function.
7.5 ft
0 3 6 10 13 16 19 23 26 29 33 36 40
(feet)
29 26 23 19 16 13 9 6 3 0 3 6 9 13 16 19 23 26 29
0
3
6
10
13
16
19
23
26
29
33
36
40
0
3
6
10
13
16
19
23
26
29
33
36
40
Tamper Switch
Sensitivity Jumper
CR123A Battery
Case Release Button
Sensor Case Screws
(feet)
(feet)
8. Operation
During normal operation, the LED will not turn on even if motion is detected. This is done to
maximize battery life. Furthermore, when motion is detected and a signal is transmitted to the
panel, the sensor will not transmit again for a period of three minutes.
9. Maintenance - Replacing the Battery
When the battery is low, a signal will be sent to the control panel.
To insert or replace the battery:
•Remove the front cover to expose the battery
•Remove the backplate using a bottom-to-top lifting motion.
•Remove the CR123A lithium battery. Note the correct orientation of the
battery as shown on the sensor cover plate.
Always match the plus (+) sign on the battery with the flat side of the
compartment and the minus (-) sign on the battery with the spring side.
•Replace the front cover.
WARNING: Failure to follow these warnings and instructions can lead to heat
generation, rupture, leakage, explosion, fire, or other injury, or damage. Do
not insert the battery into the compartment in the wrong direction. Always
replace the battery with the same or equivalent type (see Specifications on
page 1). Never recharge or disassemble the battery. Never place the battery in
fire or water. Always keep batteries away from small children. If batteries are
swallowed, promptly see a doctor.
• Always dispose and/or recycle used batteries in accordance with the
hazardous waste recovery and recycling regulations for your location. Your
city, state, or country may also require you to comply with additional
handling, recycling, and disposal requirements.
10. Environmental and Other Useful Information
•The RE611P PIR is an indoor use residential product only.
•While the PIR is a highly reliable intrusion detection device, it does not guarantee against
burglary. Any intrusion device is subject to a “failure to warn” for a variety of reasons.
Consider the following when installing and setting up the PIR:
•This PIR has built-in protection to keep bugs from getting into the sensor area and causing
false alarms. Note that this protection does not prevent insects from crawling across the
lens of the PIR, which could trigger the PIR.
•Infrared energy can be reflected off any glossy surfaces such as mirrors, windows, floors, or
counter tops with glossy finish, and slick-finished concrete. Some surfaces reflect less than
others (e.g. the PIR can see a change in infrared energy off of reflective surfaces even if the
heat or cold source is not within the PIR detection pattern).
•Windows reflect infrared energy. They also allow sunlight or light from other sources (e.g.,
cars) to pass through to the PIR. The PIR can detect these changes in infrared energy. For
example, if sunlight passing through a window shines onto a hardwood floor and the
change in infrared energy is quick enough, the PIR can trigger an alarm. The same applies if
the PIR area includes a window, even though the pattern of protection cannot “see”
through glass. Lights from a passing car can also pass through the window at night and
shine directly into the PIR’s lens.
•Heating and air conditioning ducts are also important because if they blow air onto an
object within the field of the PIR’s view, the temperature of that object could change
quickly enough for the PIR to “see” a change in infrared energy. PIR’s cannot see air
current, only the change in temperature of a physical object.
•The PIR senses change in temperature. However, as the ambient temperature of the
protected area approaches the temperature range of 95° to 120° F, the detection
performance of the PIR decreases.
•Ensure that the area you wish the PIR to cover is free of obstructions (for example,
curtains, screens, plants, and so on.) that may block the pattern of coverage.
•Anything that can sway or move due to air current can cause a change in infrared energy
within the fields of view. Drafts from doors or windows can cause this to happen. Plants,
balloons, curtains, and hanging baskets should never be left in the PIR’s field of view.
•Do not mount the PIR on a surface that allows for any vibration. Vibrations not only cause
the PIR to move a little, but it also causes the fields of view in a room to move with respect
the PIR. A little vibration can cause havoc with the PIR’s field of view, thus the PIR may see
a change in energy and trigger the alarm.
•An installation often requires that the PIR is aimed at the door. The PIR may detect door
movement before the door contact can initiate an entry delay, causing the alarm to trigger.
If you install the PIR facing a door, then while programming the PIR, choose an appropriate
sensor/zone type.
•The PIR ONLY detects intrusion within the pattern of coverage.
•The PIR does not provide volumetric area protection.
•The PIR creates multiple beams of protection. Intrusion can only be detected in
unobstructed areas covered by those beams.
•The PIR cannot detect motion or intrusion that occurs behind walls, ceilings, floors, closed
doors, partitions, glass doors, or windows.
•Tampering with, masking, painting, or spraying of any material on the PIR lens or any part
of the optical system can impair detection ability.
•The PIR, like other electrical devices, are subject to component failure. Even though the PIR
is designed to last as long as 10 years, the electronic components are subject to failure.
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Re-orient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment to an outlet on a different circuit from the receiver
• Consult the dealer or an experienced radio/TV contractor for help.
Warning: Changes or modifications not expressly approved by Ecolink Intelligent Technology Inc. could void
the user’s authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
C’et appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est
soumis aux deux conditions suivantes: (1) c’et appareil ne peut pas provoquer d'interférences, et (2) c’et
appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais
fonctionnement de la dispositif.
FCC ID: XQC-WST740 IC: 9863B-WST740
Trademarks
Alula is a trademark owned by Alula Holdings, LLC.
Panasonic is a registered trademark owned by Panasonic Corporation.
Honeywell is a registered trademark owned by Honeywell International Inc. 2GIG is a trademark
owned by Nortek Security & Control LLC. Alula products will function with one of either
Honeywell or 2GIG systems. However, no Alula product is produced by, endorsed by, nor is
officially associated with Honeywell or 2GIG. Alula recommends verifying proper enrollment
and operation, per control panel installation instructions, at installation.
Ecolink is a trademark owned by Ecolink Intelligent Technology Inc.
RE611P Designed and manufactured by Ecolink Intelligent Technology Inc. 2022.
© 2022 Ecolink
2340 Energy Park Drive
St. Paul, MN 55108
1
-888-88-ALULA
www.Alula.com
PN: 47007-00xxxxx
REV & REV Date: A03 06/13/2022

Other Alula Accessories manuals

Alula RE206M User manual

Alula

Alula RE206M User manual

Alula RE607 User manual

Alula

Alula RE607 User manual

Alula RE601 User manual

Alula

Alula RE601 User manual

Alula Home Disaster RE119 User manual

Alula

Alula Home Disaster RE119 User manual

Alula Home Disaster RE319 User manual

Alula

Alula Home Disaster RE319 User manual

Alula CAM-DB-JS1 User manual

Alula

Alula CAM-DB-JS1 User manual

Alula RE618 User manual

Alula

Alula RE618 User manual

Alula NanoMax RE122 User manual

Alula

Alula NanoMax RE122 User manual

Alula DWS-LL User manual

Alula

Alula DWS-LL User manual

Alula RE606 User manual

Alula

Alula RE606 User manual

Alula RE101 User manual

Alula

Alula RE101 User manual

Alula DWS-LL User manual

Alula

Alula DWS-LL User manual

Alula NanoMax RE322T User manual

Alula

Alula NanoMax RE322T User manual

Alula RE106M User manual

Alula

Alula RE106M User manual

Alula RE703 User manual

Alula

Alula RE703 User manual

Alula RE111P User manual

Alula

Alula RE111P User manual

Alula RE301 User manual

Alula

Alula RE301 User manual

Alula RE306 Manual

Alula

Alula RE306 Manual

Alula RE206 User manual

Alula

Alula RE206 User manual

Alula RE606M User manual

Alula

Alula RE606M User manual

Alula RE222T User manual

Alula

Alula RE222T User manual

Alula NanoMax RE322 User manual

Alula

Alula NanoMax RE322 User manual

Alula RE118 User manual

Alula

Alula RE118 User manual

Popular Accessories manuals by other brands

Teleco RAIN102H Installation

Teleco

Teleco RAIN102H Installation

Endress+Hauser Soliphant M FTM50 operating instructions

Endress+Hauser

Endress+Hauser Soliphant M FTM50 operating instructions

iOptron HAE69 quick start guide

iOptron

iOptron HAE69 quick start guide

Giacomini KLIMAdomotic K410W quick start guide

Giacomini

Giacomini KLIMAdomotic K410W quick start guide

UPPAbaby 0917-LRA-WW quick start guide

UPPAbaby

UPPAbaby 0917-LRA-WW quick start guide

rock space PE1 Quick installation guide

rock space

rock space PE1 Quick installation guide

Emos 838W quick start guide

Emos

Emos 838W quick start guide

Votronic 30-110 K-FL quick guide

Votronic

Votronic 30-110 K-FL quick guide

FOBO Xtra user manual

FOBO

FOBO Xtra user manual

Honeywell Home 5800SS1 Installation & setup guide

Honeywell Home

Honeywell Home 5800SS1 Installation & setup guide

nvent Raychem RayStat-M2-G-Sensor manual

nvent

nvent Raychem RayStat-M2-G-Sensor manual

Omron ZFV Series datasheet

Omron

Omron ZFV Series datasheet

Lippert Solera Power manual

Lippert

Lippert Solera Power manual

U-Line H-5598 manual

U-Line

U-Line H-5598 manual

EDP GEIST COOL SwitchAir 83-SA2-003 installation guide

EDP

EDP GEIST COOL SwitchAir 83-SA2-003 installation guide

Steinberg UR44 Getting started

Steinberg

Steinberg UR44 Getting started

Panasonic MAZWxxxHG Series Specification sheet

Panasonic

Panasonic MAZWxxxHG Series Specification sheet

PSS Gared GP10A72 Installation, operation and maintenance

PSS

PSS Gared GP10A72 Installation, operation and maintenance

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.