manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Alula
  6. •
  7. Security Sensor
  8. •
  9. Alula Connect+ RE659 User manual

Alula Connect+ RE659 User manual

360 PIR Motion Sensor alarms when motion is sensed.
It is a commercial battery-powered ceiling mount sensor
with a 360 degree detection range.
Features
• 360° detection range with 62 distinct detection zones
• Range up to 40 feet in diameter
• Selectable pulse count 2 or 4
• Designed for commercial applications
• 5 year warranty
Enroll by entering the serial number into the security panel.
Alternatively, the sensor can be enrolled by placing the
panel into enrollment mode, and then pulling the battery
tab or tampering the device.
Install by screwing two #8 screws into the ceiling, leaving 1/4
inch of thread exposed. Next, slide the back plate over the
screws and rotate the back plate. Screw the third #8 screw
through the wall tamper into the ceiling, ensuring that the
wall tamper screw is attached to something solid. Tighten
all screws until snug. Then, insert the square nut into the
square slit of the cover and start threading the #4 screw into
the side of the cover. Close the cover and conduct a walk
test. After testing, take the unit out of walk test mode and
close the cover again. Finally, nish threading the #4 screw
until it is snug.
Use the panel’s installation guide to verify proper system setup.
I
N
S
T
A
L
L
G
U
I
D
E
I
Mounting Tips
• Avoid direct sunlight
• Avoid facing directly to AC or heating vents
• Avoid vapor or high humidity
• Avoid curtains, screens, etc. from blocking detection
• Do not install outdoors
RE659 360 Motion Sensor
Connect+™Encrypted
Sensor Functions
Alarm LED can be switched either “ON” or “OFF”.
Pulse Count can be switched to either “2” or “4” pulse
mode depending on the environmental conditions
of the installation.
Walk Test Jumper puts sensor in Walk Test Mode when
connected or Normal Mode when not connected. The
LED will light up and an alarm will be sent whenever
motion is detected if the unit is in Walk Test Mode. In
Normal Mode, the unit will only send an alarm every 2
minutes, and the LED will only light up if the “LED ON”
jumper is connected.
Detection Range
Pulse Count
• Select “2” for normal applications.
• Select “4” for use in areas where there may be
movement by small animals or other objects,
such as fax machines or curtains.
Mounting and Jumper Locations
LED
Pulse Count
Troubleshooting
Problem Probable Cause Remedy
Alarm is not activated
although someone is
walking in detection
area
Detection area is improper,
battery is dead, Walk Test
switch is OFF and 2 minute
delay is active
Conduct a walk test, change
the battery
Alarm is activated with
nobody in the area
Moving object within
detection area, temperature
of object within area is
changing rapidly
Remove the object from
the detection area, remove
the heat sources from the
detection area or relocate the
detector
LED does not light up
at the time of the walk
test
Walk test switch is OFF,
battery is dead
Turn the walk test switch ON,
change the battery
LED does not light up
in normal operation
LED switch is OFF, battery
is dead
Turn LED switch ON, change
battery
Pro Tips
Save battery life by taking unit out of walk test mode after
completing walk test. There is no 2 minute delay when
in walk test mode. Leaving in walk test mode will
severely decrease battery life.
Light changes will cause the sensor to trip. Ensure that the
detector is not placed near windows.
Sudden temperature changes will cause the sensor to trip.
Ensure the motion detector is not placed near heating
and cooling vents.
High humidity environments can cause condensation of
the detection lens. Ensure the motion detector is not
installed in these kinds of environments.
Protective lm should be removed from the lens after
installation.
Sensor Specications: The table below displays the
functional frequencies of each compatible sensor.
47-0047-08 • RevB • 2018-03-19
Tech Support Line • (888) 88-ALULA • (888) 882-5852
alula.net
WARRANTY
Alula will replace all non-portable products that are defective
in their rst ve (5) years, and all portable products that are
defective in their rst two (2) years.
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including
interference that may cause undesired operation of the
device.
Le présent appareil est conforme aux cnr d’Industrie
Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) L’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionnement.
IC: 8310A-RE359
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modications not expressly approved by Alula could
void the user’s authority to operate this equipment.
FCC ID: U5X-RE359
TRADEMARKS
Alula and Connect+ are trademarks owned by Alula Holdings, LLC.
Specications
Physical
Housing Dimensions
Weight with Battery
Mounting Fasteners
4.72 x 1.57 inches (40 x 120 mm)
4.2oz (120g)
(3) #8 screws, (1) square nut, (1) #4 screw (All provided)
Environmental
Operating Temperature
Maximum Humidity
32°F to 120°F (0°C to 49°C)
85% non-condensing relative humidity
Sensor Specications
Frequencies
Replacement Battery
Nominal Battery Life
Battery Voltage
Current Draw
Detection Range
Detectable Speed
Transmitted Indications
433.92 MHz
One Panasonic CR123A Lithium Battery
3 years (assuming 720 trips/day), 7 years (assuming 240 trips/
day)
3.0 VDC (Nominal), 2.7 VDC (Low)
21 mA (Maximum), 4.7 uA (Standby), 30 mA (Max in walk test)
Up to 40 Feet (12 m)
1 to 5 feet per second (0.3 to 1.5 meters per second)
Motion, Tamper (Cover/Wall), Low Battery, Supervision
Certication
RE659 UL639, ULC-S306-03, ETL, FCC, IC
Specications subject to change without notice

Other Alula Security Sensor manuals

Alula RE629 Glassbreak Connect+ Encrypted User manual

Alula

Alula RE629 Glassbreak Connect+ Encrypted User manual

Alula RE611P User manual

Alula

Alula RE611P User manual

Alula RE300-5 User manual

Alula

Alula RE300-5 User manual

Alula RE619 User manual

Alula

Alula RE619 User manual

Alula RE129 User manual

Alula

Alula RE129 User manual

Alula RE307 User manual

Alula

Alula RE307 User manual

Alula RE209 User manual

Alula

Alula RE209 User manual

Alula RE610P-OS User manual

Alula

Alula RE610P-OS User manual

Alula RE109 User manual

Alula

Alula RE109 User manual

Alula RE106 User manual

Alula

Alula RE106 User manual

Alula RE310P User manual

Alula

Alula RE310P User manual

Alula RE636 Wireless Outdoor Siren Strobe Connect+... User manual

Alula

Alula RE636 Wireless Outdoor Siren Strobe Connect+... User manual

Alula RE219 User manual

Alula

Alula RE219 User manual

Alula RE200-5T User manual

Alula

Alula RE200-5T User manual

Alula RE210T User manual

Alula

Alula RE210T User manual

Alula RE359 User manual

Alula

Alula RE359 User manual

Alula RE129 User manual

Alula

Alula RE129 User manual

Alula RE610P User manual

Alula

Alula RE610P User manual

Alula RE210P User manual

Alula

Alula RE210P User manual

Alula RE609 User manual

Alula

Alula RE609 User manual

Alula RE229 User manual

Alula

Alula RE229 User manual

Alula RE110P User manual

Alula

Alula RE110P User manual

Alula RE309 User manual

Alula

Alula RE309 User manual

Popular Security Sensor manuals by other brands

RKI Instruments 35-3010RKA-03 manual

RKI Instruments

RKI Instruments 35-3010RKA-03 manual

Petzl SEQUOIA SRT manual

Petzl

Petzl SEQUOIA SRT manual

RIDGID micro CD-100 Operator's manual

RIDGID

RIDGID micro CD-100 Operator's manual

SiCEP BiTech BT-CMW manual

SiCEP

SiCEP BiTech BT-CMW manual

HWM PCorr+ manual

HWM

HWM PCorr+ manual

Leuze electronic OPSL 775 manual

Leuze electronic

Leuze electronic OPSL 775 manual

NookBox IRD-23 installation guide

NookBox

NookBox IRD-23 installation guide

LEGRAND LE03020AB quick start guide

LEGRAND

LEGRAND LE03020AB quick start guide

C-LOGIC 640-MD instruction manual

C-LOGIC

C-LOGIC 640-MD instruction manual

SENKO SI-560 instruction manual

SENKO

SENKO SI-560 instruction manual

PCB Piezotronics IMI SENSORS Echo TO670A02 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS Echo TO670A02 Installation and operating manual

IFM Electronic EFECTOR 500 PD70 Series operating instructions

IFM Electronic

IFM Electronic EFECTOR 500 PD70 Series operating instructions

AccuBANKER QuadScan D470 user guide

AccuBANKER

AccuBANKER QuadScan D470 user guide

CIAS Elettronica S.r.l. MURENA PLUS 12 installation manual

CIAS Elettronica S.r.l.

CIAS Elettronica S.r.l. MURENA PLUS 12 installation manual

Innogy WMDO instructions

Innogy

Innogy WMDO instructions

Hikmicro HM-TD1018-1/QR quick start guide

Hikmicro

Hikmicro HM-TD1018-1/QR quick start guide

Kobold OPT operating instructions

Kobold

Kobold OPT operating instructions

DeFelsko PosiTest High voltage Holiday Detector instruction manual

DeFelsko

DeFelsko PosiTest High voltage Holiday Detector instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.