Amana MBVC Series User manual

SS-AMBVC www.amana-hac.com 3/20
Amana® is a trademark of Maytag Corporaon or its related companies and used under license to Goodman Company, L.P., Houston, Texas. Supersedes 7/17
Multi-Position, Variable-Speed
ECM-Based, Modular Blower
ComfortBridge™ Compatible
* Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the
10-Year Parts Limited Warranty, online registraon must be completed within 60 days of installaon. Online
registraon is not required in California or Québec.
Product Features
• Variable-speed ECM blower motor
• Integrated communicang ComfortBridge™ Technology
• Commissioning and diagnoscs via on board Bluetooth
with the CoolCloud phone and tablet applicaon
• Advanced conguraon of the airow
and tonnage in communicang mode
• Provides constant CFM over a wide range of stac
pressure condions independent of duct system
• CFM indicator
• Fault recall of six most recent faults
• Provides adjustable low CFM for
ecient fan-only operaon
• Improved humidity and comfort control
• Built-in compability with mul-stage
heat pump and cooling applicaons
• Blower secon usable as electric heater
• AHRI cered; ETL listed
• Horizontal or vercal conguraon capabilies
• 21" depth for easier ac access
• Foil-faced insulaon covers the internal
casing to reduce cabinet condensaon
• Galvanized, leather grain-embossed nish
• Cabinet air leakage less than 2% at 1.0 inch
H₂0 when tested in accordance with
ASHRE standard 193
• Cabinet air leakage less than 1.4% at 0.5 inch
H₂0 when tested in accordance with
ASHRE standard 193
• Field Installed 3 kW – 25 kW electric heater
kits available
Contents
Air Handler Nomenclature.................... 2
Heater Kit Nomenclature...................... 2
Product Specicaons........................... 3
Airow Data ........................................... 3
Heat Kit Data.......................................... 4
Dimensions ............................................ 5
Wiring Diagram...................................... 6
MBVC

2www.amana-hac.com SS-AMBVC SS-AMBVC www.amana-hac.com 3
UnitType Revisions
HKR AirHandlers&PackagedUnits EngineeringRevisions
HKA AirHandlers
HKP PackagedUnits
CircuitBreaker
None Singleor3PhaseKit;
Phase NoCircuitBreaker
None SinglePhase C SinglePhaseKitw/
3 ThreePhase CircuitBreaker
HeatingCapacity@240Volts
5 4.75kW 15 14.25to15.00kW
8 7.00kW 20 19.00to19.60kW
10 9.50kW
* A
1 2 3 4,5 11
HKR * 05
Nomenclature
MB VC 12 01 A A 1
1,2 3,4 5,6 7,8 9 10 11
Design Series Electrical
MB Modular Blower 1 208- 230/60/1
Revisions
Motor Speed A First Series
V Variable Speed ECM Motor
CCommunicang Circuit Breaker
A No Circuit Breaker
B Circuit Breaker
12 1200 CFM
16 1600 CFM
20 2000 CFM
00 ComfortNet® Compable
01 ComfortBridgeTM Compable

2www.amana-hac.com SS-AMBVC SS-AMBVC www.amana-hac.com 3
MBVC1201AA-1 MBVC1601AA-1 MBVC2001AA-1
Diameter 10" 10" 11"
Width 8" 8" 10"
Voltage 208 / 230 208 / 230 208 / 230
Min Circuit Ampacity 4.9 6.5 6.5
Max. Overcurrent Device (Amps) 15 15 15
Horsepower (HP) ½ ¾ ¾
67 80 86
• Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protecon (MOP) for blower without
supplemental heat installed. Refer to unit nameplate for these specicaons with approved accessory
heaters installed.
• Condensate management kits are available for units installed in high temperature and high humidity areas. Kit number MBK0002 has
beendeveloped to resolve condensate issues in the eld for MBVCs and is available from the Service Parts Department. Refer to IO-849
for installaon instrucons.
Product Specifications

4www.amana-hac.com SS-AMBVC SS-AMBVC www.amana-hac.com 5
Airflow Data
MBVC1201A*
ALow 420 415 400 400 395 390 390 390 380
BLow 550 545 540 540 535 530 530 525 520
CLow 680 675 670 665 660 655 655 650 640
DLow 810 805 800 800 800 795 790 785 785
AHigh 615 605 600 600 595 590 590 585 580
BHigh 805 805 800 800 800 795 790 785 780
CHigh 1010 1005 1000 1000 995 995 990 985 975
DHigh 1210 1205 1200 1200 1200 1195 1195 1190 1180
MBVC1601A*
ALow 690 680 670 665 660 655 625 595 575
BLow 850 830 800 795 790 785 775 750 725
CLow 980 970 940 935 930 910 890 865 860
DLow 1110 1085 1070 1055 1045 1025 1000 990 975
AHigh 1045 1015 1000 990 975 950 935 920 900
BHigh 1245 1215 1200 1180 1175 1165 1150 1130 1115
CHigh 1415 1410 1400 1365 1360 1350 1340 1330 1320
DHigh 1605 1600 1600 1540 1530 1520 1510 1500 1490
MBVC2001A*
ALow 835 815 800 800 795 795 790 775 750
BLow 1075 1070 1070 1065 1050 1045 1045 1040 1035
CLow 1210 1205 1200 1200 1195 1190 1190 1185 1175
DLow 1345 1340 1340 1320 1320 1315 1315 1305 1305
AHigh 1210 1205 1200 1195 1150 1150 1145 1135 1115
BHigh 1610 1605 1600 1540 1535 1535 1530 1520 1510
CHigh 1830 1805 1800 1785 1760 1760 1755 1750 1715
DHigh 2020 2010 2000 1995 1995 1970 1970 1965 1955
S1 S2 MBVC1201
MBVC1601
MBVC2001
o o A600 1000 1200
on o B800 1200 1600
o on C1000 1400 1800
on on D1200 1600 2000
S3 S4 Trim Value S5 S6
o o 0o o A
on o 10% on o B
o on -10% o on C
on on 0on on D
• The chart is for informaon only. For sasfactory operaon, external stac pressure must not exceed value shown on rang plate.
• Use the CFM adjustment factors of .98 for horizontal le, .95 for horizontal right & .96 for downow orientaons.

4www.amana-hac.com SS-AMBVC SS-AMBVC www.amana-hac.com 5
MCA¹ MCA¹ MCA¹
MBVC1201AA-1A*
HKR-03*
HKR-05* / 05C*
HKR-06*
HKR-08* /-08C*
HKR-10* /-10C*
HKA-15C*
0 / 0
10.8 / 12.5
17.2 / 19.8
21.7 / 25.0
25.3 / 29.2
34.3 / 39.6
34.3 / 39.6
4.9 / 4.9
18 / 20.5
26 / 29.6
32 / 36.1
36.5 / 41
47.8 / 54
47.8 / 54
15 / 15
20 / 25
30 / 30
35 / 40
40 / 45
50 / 60
50 / 60
---
---
---
---
---
---
17.2 / 19.8
---
---
---
---
---
---
21.4 / 24.7
---
---
---
---
---
---
25 / 25
---
---
---
---
---
---
69/79
---
---
---
---
---
---
70 / 80
MBVC1601AA-1A*
HKR-03*
HKR-05* / 05C*
HKR-06*
HKR-08* /-08C*
HKR-10* /-10C*
HKA-15C*
0 / 0
10.8 / 12.5
17.2 / 19.8
21.7 / 25.0
25.3 / 29.2
34.3 / 39.6
34.3 / 39.6
6.5 / 6.5
20.1 / 22
27.9 / 31
34 / 37.8
38.1 / 43
49.4 / 56
49.4 / 56
15 / 15
25 / 25
30 / 35
35 / 40
40 / 45
50 / 60
50 / 60
---
---
---
---
---
---
17.2 / 19.8
---
---
---
---
---
---
21.4 / 24.7
---
---
---
---
---
---
25 / 25
---
---
---
---
---
---
71/81
---
---
---
---
---
---
80 / 90
MBVC2001AA-1A*
HKR-03*
HKR-05* / 05C*
HKR-06*
HKR-08* /-08C*
HKR-10* /-10C*
HKA-15C*
HKA-20C*
0 / 0
10.8 / 12.5
17.2 / 19.8
21.7 / 25.0
25.3 / 29.2
34.3 / 39.6
34.3 / 39.6
34.3 / 39.6
6.5 / 6.5
20.1 / 22
27.9 / 31
34 / 37.8
38.1 / 43
49.4 / 56
49.4 / 56
49.4 / 56
15 / 15
25 / 25
30 / 35
35 / 40
40 / 45
50 / 60
50 / 60
50 / 60
---
---
---
---
---
---
17.2 / 19.8
34.3 / 39.6
---
---
---
---
---
---
21.4 / 24.7
42.9 / 49.5
---
---
---
---
---
---
25 / 25
45 / 50
---
---
---
---
---
---
70/80
92/105
---
---
---
---
---
---
70 / 80
100 / 110
All ampacies noted above include air handler motor amps
Circuit 1: Single-phase for Air Handlers / Circuit 2: Three-phase for HKR3 Heater Kits
¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25
² Maximum Overcurrent Protecon = 2.25 X Motor Amps + Heater Amps
* Revision level that may or may not be designated
C = Circuit Breaker Opon
--- indicates Not Required
• Only applicable when HKA kits are included in table
HKA meets the new UL1995 requirements for 15 and 20KW heaters
• MBVC and MBR models
Heat Kit Data
Heating kW Correction Factor
240 230 220 210 208
1.00 0.92 0.84 0.77 0.75
Mulply the 240-volt heang capacity by correcon factors.

6www.amana-hac.com SS-AMBVC SS-AMBVC www.amana-hac.com 7
Dimensions
MBVC1201AA-1 17½" 21" 26"
MBVC1601AA-1 21" 21" 30"
MBVC2001AA-1 24½" 21" 30"
Top View
SMALLMEDIUMLARGE
8.840
10.159
16.500
11.029
11.209
20.021
13.178
11.209
23.464
17½"21"24½"
Side and Front Views

6www.amana-hac.com SS-AMBVC SS-AMBVC www.amana-hac.com 7
Wiring Diagram – Air Handler
⚠Warning High Voltage: Disconnect all power before servicing or installing this unit. Mulple power
sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
CIRCULATOR BLOWER
1
1
CIRCULATOR
CIRCULATOR
RD
WH
TO
MICRO
AUX IN
AIR
230 VAC
PL1
SEE
NOTE 7
DEHUM
24 VAC
RD
4
BLWR
5
AIR
40 VA
8
40 VA TRANSFORMER, SEE NOTE 1
L1
9
INDOOR
7
24 VAC
4
BK
1
5
BL
PL2
FUSE 3 A
208/230 VAC
GRND
ECM MOTOR
HARNESS
GRND
6
L2
6
L1
COM
BR
G
INTEGRATED CONTROL MODULE
W
BK
3
24V THERMOSTAT CONNECTIONS
COM
L2
DISCONNECT
BL
BK
TR2
C
3
GRND (4)
2
2
INDOOR
9
RD
TH2
+VDC (1)
Y
208 VAC
BK
RX (2)
RD
GRND
GRND
4
GN
R
8
5
EH1
RD
TX (3)
BL
3
GRND
ELECTRIC STAGE 2
RD
TRANSFORMER
ELECTRIC HEAT STAGE 1
GN
7
2
BLWR
EQUIPMENT GRND
TERMINAL
PLUG CONNECTION
LOW VOLTAGE FIELD
HI VOLTAGE FIELD
JUNCTION
HI VOLTAGE (230V)
PROT. DEVICE
INTEGRATED CONTROL
LOW VOLTAGE (24V)
FIELD SPLICE
INTERNAL TO
FIELD GRND
OVERCURRENT
BK ---- BLACK
OR ---- ORANGE
BL ---- BLUE
PK ---- PINK
GY ---- GRAY
RD ---- RED
WH ----WHITE
PU ---- PURPLE
YL ---- YELLOW
BR ---- BROWN
COLOR CODES:
GN ---- GREEN
NOTES:
1. PLACE RED WIRES ON TRANSFORMER TERMINAL 2 FOR 208 VAC OPERATION.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL
HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY.
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C AND LOCAL CODES.
5. TO RECALL THE LAST 6 FAULTS, DEPRESS THE RIGHT PUSH BUTTON FROM STATUS MENU ONCE AND THEN
USE THE LEFT OR RIGHT BUTTON TO REVIEW ALL THE FAULTS HISTORY.
6. 2 GREEN LEDS INDICATES CLIMATE TALK AND DATAAC NETWORK TRAFFIC STATUS. USE LEARN MENU FOR CLIMATE TALK NETWORK RESET.
7. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT.
8. THE CONDENSATE ALARM SWITCH (AUX) TERMINALS CAN ONLY BE UTILIZED WITH COMMUNICATING MODE SETUPS AND MUST BE ENABLED WITH
COMMUNICATING THERMOSTAT. THIS FEATURE IS NOT OPERATIONAL WITH NON COMMUNICATING SYSTEMS.
9. USE N.E.C CLASS 2 WIRE.
10. SEE MANUAL FOR PUSH BUTTON OPERATION
11. SEE MANUAL FOR 7-SEGMENT DISPLAY DIAGNOSTIC CODES AND MENU CODES
12. SEE MANUAL FOR LEDS FUNCTIONALITY
13. R AND C TERMINALS (USED FOR 24VAC OUTDOOR CONTROL VOLTAGE) ARE OPTIONAL FOR 2 STAGE COMMUNICATING AIR CONDITIONERS. R AND C TERMINALS
ARE NOT TO BE USED FOR 2 STAGE COMMUNICATING HEAT PUMP APPLICATIONS.
FOR COMMUNICATING HEAT PUMP OR IF ONLY TWO THERMOSTAT WIRES ARE AVAILABLE, A SEPARATE TRANSFORMER MUST BE INSTALLED IN THE OUTDOOR
UNIT FOR CONTROL BOARD POWER.
1 AND 2 WIRES ARE REQUIRED FOR ALL APPLICATIONS. SEE INSTALLATION MANUAL FOR FULL SYSTEM WIRING EXAMPLES. 0140A00705-A
1
2
3
CONDENSATE SWITCH
AUX OUT
EH2
RESISTOR
432
1
SEE NOTE 9
4 - GND
NC
SEE NOTE 6
GY PUWH GR BL RD BL RD GY BK
THERMOSTAT OUTDOOR UNIT
(SEE NOTE 13)

8www.amana-hac.com SS-AMBVC SS-AMBVC www.amana-hac.com PB
Amana® is a trademark of Maytag Corporaon or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our connuing
commitment to quality products may mean a change in specicaons without noce. © 2020 Goodman Company, L.P. • Houston, Texas • Printed in the USA.
Wiring Diagram – Five-Element Heater Kit
M9
M10
TL
FL
HTR1
HTR2
HTR3
HTR4
M6
M5
L2
L2 L1
RD
BL
BK
YL
RD
BK
BK
RD
M1 M3
YL
BL
BK RD
M2
R1
M4
PU
9
8
WH
M8
7
6
BR
5
M7
R2
BL
RD
BL
4
3
2
BL
YL
BK
1
PC
RD
BK
HTR5
L1
L2
L1
BL
R3
PU
PU
1L 2L
CB4
CB3 CB1 CB2
WH
PU
TL
FL
TL
FL
TL
FL
TL
FL
COLOR CODE
BK = BLACK
BL = BLUE
BR = BROWN
PK = PINK
RD = RED
WH = WHITE
YL = YELLOW
WIRING CODE:
HIGH VOLTAGE
LOW
VOLTAGE
COMPONENT CODE
PC = 9 PIN CONNECTOR
HTR = HEATER ELEMENT
TL = THERMAL LMT
RS = RELAY/SEQUENCER
TB = TERMINAL BLOCK
CB = CIRCUIT BREAKER
CC = CONTACTOR
FL = FUSE LINK
TR = TRANSFORMER
SR = STRAIN RELIEF
EM = EVAPORATOR MOTOR
EBTDR = ELEC. BLOWER TIME DELAY
RC = RUN CAPACITOR
GR = GREEN
OR = ORANGE
PU = PURPLE
0140M00274-A
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR
EQUAL THE MINIMUM BLOWER
SPEED (MBS) SPECIFIED FOR THE AIRHANDLER /
HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING
OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW.
NO MARK INDICATES NO HEAT KIT INSTALLED.
FIVE (5) ELEMENT ROWS
NOTE:-
THIS LABEL MUST BE ATTACHED ON THE
AIRHANDLER IN A PROMINENT LOCATION
BK RD BK
RD
⚠Warning High Voltage: Disconnect all power before servicing or installing this unit. Mulple power
sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
Other manuals for MBVC Series
2
This manual suits for next models
3
Table of contents
Other Amana Fan manuals
Popular Fan manuals by other brands

NSA
NSA TF-31RC instruction manual

Home Decorators Collection
Home Decorators Collection BENTLEY III AL14-22-BN Use and care guide

Craftmade
Craftmade Wellington series installation instructions

Broan
Broan B180H75rT User's and installer's manual

Harbor Breeze
Harbor Breeze LAKE LAGODA LP8300LAZ manual

INNOLIVING
INNOLIVING INN-512 user manual