manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Amber
  6. •
  7. Industrial Equipment
  8. •
  9. Amber Vest User manual

Amber Vest User manual

User’s Manual
Phosphate bound investment for casting press ceramics
with normal or quick heating
Vest
CASTING TEMPERATURE: 850°C
Maintain the cylinder at the final temperature for:
After the casting has been
completed, bench-cool the ring
to room temperature.
Do not quench in cold water!!
250℃
850℃
25″/ 35″
40″
CYLINDER SIZE HEATING TIME
1 x
25 min
3x 35 min
Amber Vest POWDER
Store at 18-25°C.
Keep the packages tightly closed in a dry place.
The investment is sensitive to moisture: prolonged exposure to the air may alter the
characteristics of the product.
EXPANSOR-B LIQUID
Store at 18-25°C.
Prolonged exposure to temperatures lower than 5°C or higher than 35°C may produce freezing
and/or destabilisation of the product.
Do not use the liquid if it shows a sign of cristallization.
Keep the bottles tightly closed after each use. Prolonged exposure to the air may cause crystallisation.
Batch number and expiry date are marked on each package.
This material contains silica.
DO NOT INHALE THE POWDER!
Continued inhalation of the powder
may cause lung injury (silicosis or cancer).
During handling, avoid the formation of powder. Avoid inhalation by using a suitable dust mask.
Eliminate any spillages of powder with a damp cloth.
Avoid the formation of powder during deflasking by submerging the cylinder completely cold in
water. Extract the ammoniac vapours from preheating and emit them to the exterior.
Avoid skin contact with the mixing liquid EXPANSOR. In the event of contact, wash with soap
and water. In the event of contact with the eyes, wash under abundant running cold water and
consult a doctor.
Polígono Empordà Internacional 17469 VILAMALLA, GIRONA • SPAIN
Tel.: ( 34 ) 972 52 61 69 / Fax: ( 34 ) 972 52 55 86
[email protected] / www.protechno.com
Manufacturer : Distributor :
5℃
MIN.
35℃
MAX.
Vest
77-14, Gwahakdanji-ro, Gangneung-si, Gangwon-do, KOREA 25452
Tel: 070-7712-1300 / Fax: 033-644-1231
Customer Support: 02-2083-1367 / www.hassbio.com
User’s Manual
1506EN_170711
STORAGE AND EXPIRY
SAFETY INSTRUCTIONS
DESCRIPTION
Amber®Vest is an ultra fine, graphite-free, phosphate bound investment for casting press ceramics with
the technique of NORMAL OR QUICK HEATING.
According to ISO 15912:2006, the classification of the product is Type 1 Class 2.
INSTRUCTIONS OF USE
1. LIQUID PREPARATION:
DO NOT USE EXPANSOR LIQUID WHICH HAS BEEN FROZEN (BECOME CRYSTALLISED).
WARNING:
DO NOT USE BOWLS NEITHER
CONTAINERS WHICH HAVE BEEN
IN CONTACT WITH PLASTER.
As with all phosphatic coatings, the temperature of storage and preparation of the coating and of the mixing liquid is
a determining factor in the expansion during setting, and therefore in the precision of fit and the cast surface.
The optimum preparation temperature is 20-22°C. Any variation in the optimum working temperature, whether of
the powder, liquid or mixing utensils, or significant variations in the ambient temperature, affect the behavior
of the product.
2. PREPARATION OF THE CYLINDER
Metal ring and plastic or silicone cylinders can be used.
For 9x cylinders, use always metal ring.
• WITH metal ring:
- Cover the inner part of the cylinder with a quartz band (for example RING-O-LINER).
(1 layer for 1x and 3x cylinders / 2 layers for 6x and 9x)
- Moisten slightly with water the band to prevent the absorption of the investment.
• WITHOUT ring (plastic or silicone cylinder, for example RING-O-EXPAND Press):
Apply a fine layer of Vaseline to facilitate subsequent extraction.
• To obtain good results, it is essential to use the precise measurements.
• For greater ease of use, Amber®Vest is supplied in pre-dosed sachets of 100g,
and a dosing tube is supplied for the liquid.
• It is recommended always to use whole sachets and to measure the liquid with the original
dosing tube.
• In the case of using non-pre-dosed portions of powder, weigh the exact contents with a scale.
The powder-liquid proportion is: 100g powder/25ml liquid:
3. PREPARATION FOR MIXING
Concentrations of the mixing liquid: 70 % EXPANSOR-B + 30 % DISTILLED WATER
CYLINDER SIZE POWDER MIXING LIQUID
1 x
100 g 25 ml
3 x
200 g
50 ml
6 x
300 g
100 ml
4. MIXING
• Prepare the mixing liquid (EXPANSOR-B + distilled water).
• Add the powder to the liquid and mix briskly by hand for 15-20 seconds to obtain
a totally moist and uniform mass.
• Then pass to mechanical vacuum mixing for 60 seconds depending on the mixer.
7. HEATING
• Few minutes before placing in the furnace, scrape with a knife the upper surface
of the cylinder to allow the gases to escape.
• Place the cylinders in the furnace with the spouts downwards.
• In the case of multiple cylinders, also avoid any contact between them.
• Due to the aggressive elimination of the wax, do not open the furnace while heating.
Heating can be carried out in two different ways:
PLACING IN THE FURNACE
5. FILLING THE CYLINDER
Amber®Vest flows over wax surfaces without the need to paint them with degreasing
agents. We recommend the application of a thin layer of TENSIO-WAX over the wax cast
before the coating. When the mixing time is completed, fill the cylinder, vibrating gently,
for 10-15 seconds, then stop.
6. WORKING TIME
7-8 minutes (20-22°C) from the moment that powder and liquid contact.
• The working time can be reduced when the liquid is at a higher temperature.
• With ambient temperatures above 22°C.
• With the use of contaminated utensils.
HEATING
After the mixing, place the cylinder in the furnace for 20-30
minutes at the final casting temperature.
900℃
Fast heating:
• Place the cylinder in the furnace after the setting.
• Dry at 250°C for 40 minutes.
• Heat up at 7°C / min. to the casting temperature.
Normal heating:
User’s Manual User’s Manual
Vest Vest
WARNING:
Wax ignition can lead to
breakings. Place the cylinders
inclined or over investment
plates. Never place them
directly on the oven base.
IMPORTANT: Amber®Vest must be always used with the special liquid
EXPANSOR-B and distillated water. The dilutions can be effected by adding
distilled or demineralised water, shaking slightly and then applying to the bottle
an identifying label of the concentration made.

Other Amber Industrial Equipment manuals

Amber M32 Instruction Manual

Amber

Amber M32 Instruction Manual

Amber api SmartScan V5.0 User manual

Amber

Amber api SmartScan V5.0 User manual

Amber AC2600 User manual

Amber

Amber AC2600 User manual

Popular Industrial Equipment manuals by other brands

ABB HT610347 Operation manual

ABB

ABB HT610347 Operation manual

Emerson Yarway Installation, operation and maintenance instructions

Emerson

Emerson Yarway Installation, operation and maintenance instructions

TLV JH7.5R-P Insruction manual

TLV

TLV JH7.5R-P Insruction manual

SCHUNK ERM Series Short manual

SCHUNK

SCHUNK ERM Series Short manual

Amada SC-181C-00 Operation manual

Amada

Amada SC-181C-00 Operation manual

Festo VMPAL-LW Assembly instructions

Festo

Festo VMPAL-LW Assembly instructions

Euromair EUROPRO 30+ user manual

Euromair

Euromair EUROPRO 30+ user manual

Wilo Wilo-Flumen EXCEL-TRE 20 Installation and operating instructions

Wilo

Wilo Wilo-Flumen EXCEL-TRE 20 Installation and operating instructions

Afag PDZ-128 Assembly and operating instructions

Afag

Afag PDZ-128 Assembly and operating instructions

KTR ROTEX BTAN Mounting instructions

KTR

KTR ROTEX BTAN Mounting instructions

Metso Outotec Lokotrack ST3.8 DRIVING INSTRUCTION

Metso Outotec

Metso Outotec Lokotrack ST3.8 DRIVING INSTRUCTION

Siemens simovert EMC-Filter Compact PLUS operating instructions

Siemens

Siemens simovert EMC-Filter Compact PLUS operating instructions

ABB HT575645 Operation manual

ABB

ABB HT575645 Operation manual

Cirs 054GS user guide

Cirs

Cirs 054GS user guide

ABB HT843539 Operation manual

ABB

ABB HT843539 Operation manual

Taktomat RT Series operating instructions

Taktomat

Taktomat RT Series operating instructions

DRIESCHER-WEGBERG LDTM 12/630 F-E EA-E Operation and assembly instructions

DRIESCHER-WEGBERG

DRIESCHER-WEGBERG LDTM 12/630 F-E EA-E Operation and assembly instructions

Kostal INVEOR MA operating manual

Kostal

Kostal INVEOR MA operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.