SAFETY PHOTOCELLS MODEL 9044 AND 9044-PW (PRE-WIRED RECEIVER)
INSTALLATION MANUAL
Page 2
Amber Controls. 3 Gisborne Close, Yoxall, Staffordshire, DE13 8NU England.
el: ++44-1543-732-094 sales@amber-controls.com
Both packages include the following items:
A battery powered Infrared ransmitter Photocell fitted with 2 Energiser
Ultimate Lithium AA Batteries, providing a 5-year battery life.
A Receiver Photocell. (Note that the Receiver of the PW version is pre-wired
with 2 metres/6.5 Feet of 4-core cable to save installation time wiring to the
door Control unit.
2 Main bracket sections.
2 Extension bracket sections.
4 M5 x 12mm Pan Head Screws for joining the two bracket sections together.
4 M5 Flange Nuts for above.
4 EK screws for fixing that assembled brackets to a wall at the side of the
door.
6 M3 X 16mm Pan Head screws for fixing the photocells to the main bracket
sections
6 M3 Flange Nuts for above.
HOW TO REMOVE THE TOP COVER
Note that a small black self-tapping screw is fitted under the small
facia cover of each photocell to secure the top moulding to the base.
Use a small flat blade screwdriver
to lever up the bottom of the
small black plastic screw cover.
hen use a small Pozi-Drive screwdriver to remove the screw
Assemble the wall bracket sections using the M5 screws and Flange nuts.
he reach of the main bracket may be adjusted dependant on which two sets of holes are
used to bolt the two parts together, as shown in the picture on page one.
It is important to position the photocells with the infrared window uppermost and the body
protected from side impacts by the bracket side plate.