INSTALLAZIONE
Eseguire in sequenza le seguenti operazioni :
configurare i jumper J11, J12 e LAUNCHING in funzione della modalità di attivazione della sirena;
collegare la batteria tampone da 12 V 2 Ah ai fili rosso e nero con faston.
collegare l’alimentazione esterna da 13,8 V ai morsetti SUPPLY
collegare la linea “positivo a mancare/dare” o “negativo a mancare/dare” al morsetto START
i contatti antiapertura e antistrappo sono collegati in serie e devono essere connessi al relativo
circuito della centrale di allarme attraverso i contatti TAMPER
regolare il trimmer per la temporizzazione del suono e lampeggio desiderati
chiudere il contro-coperchio in metallo con le apposite viti
chiudere la sirena con il coperchio in plastica
ENGLISH
The SR137 is a high-power back-up battery siren (105 dB at 3m) protected against tampering (opening,
tearing off a and anti-foam). It features a 10W flasher and a sound/flash timer, variable with adjustable
trimmer from 1 min. to 7 min., which trips in case of prolonged alarm (eg. connection cable cutting). It has a first
switch-on stop function to prevent the siren from tripping during installation. (for enabling the siren for normal
use it’s necessary to activate/deactivate alarm start).
TECHNICAL SPECIFICATIONS
Rated power voltage: 13.8 VDC
Operating limit voltages: 10 15 VDC
Amp draw at max power: 1.5 A
Amp draw when not operating: 2.5 mA
Fundamental Frequency: 1622 Hz
Sound pressure (at Vn=12VDC): 105 dB(A) at 3 m
Light power: 10W
Sound and flash timer: from 1’ to 7’ ± 20%
Buffer battery: 12 VDC , 2 Ah
Dimensions: 236mm(L) x 280mm(H) x 99mm(P)
Weight (with battery): 2700g
Operating temperature: - 25 °C + 55 °C
Flashing short-circuit protection fuse: 2A
IP grade IP 54
ADJUSTMENTS AND CONNECTIONS
Trimmer TR1 : sound and flashing timer adjustment from 1’ to 7’ ± 20%
TAMPER terminals : contact N.C. resistant to opening and rip-off
SUPPLY terminals : 13.8 VDC power supply ( rated )
START terminal :
“positive missing”Jumper J11= open
Jumper J12= female jumper on B
Jumper LAUNCHING= female jumper on OFF
“negative missing”Jumper J11= closed
Jumper J12= female jumper on A
Jumper LAUNCHING= female jumper on OFF
“Start with positive”Jumper J11= open
Jumper J12= female jumper on A
Jumper LAUNCHING= female jumper on OFF
Connect a 10Kohm resistor between terminal “START” and terminal “-12V”
“Start with negative”Jumper J11= open
Jumper J12= female jumper on B
Jumper LAUNCHING= female jumper on OFF
Connect a 10Kohm resistor between terminal “START” and terminal “+12V”
“launching”Jumper J11= open
Jumper J12= female jumper on A
Jumper LAUNCHING= female jumper on ON
In the “launching” mode, the “+12v” terminal must be connected to the “start” terminal (no back-up battery)