Operational
Manual Pan/Tilt Speed .....1° to 50° per second (based on zoom position)
Preset Pan/Tilt Speed.......100° per second, maximum
Pan Travel ...............360° continuous
Tilt Travel ................> 90°
Pan/Tilt Accuracy .........± 0.5°
Zoom/Focus Accuracy .....± 0.5%
Optical Zoom .............22X
Digital Zoom ..............11X
Bubble Density ...........Clear (f0.0) or smoked (f1.0)
Programmable Patterns .....Three
Auto Synchronization
Line-Locked ............Remote V-phase adjustment
Internal ................Built-in sync generator
Address Range
RS-422/RS-485 .........One to 96
Manchester ............One to 64
SensorNet .............One to 255
Alarm Inputs .............One (Optima only)
Auxiliary Relay
Outputs .................One (Optima only)
Electrical
Input Voltage . . . . . . . . . . . . .24 to 30 VAC, Class 2 LPS
Design Tolerance ..........16 to 36 VAC
Line Frequency ...........50/60 Hz
Power Consumption
Indoor .................21 W maximum
Outdoor ...............80 W maximum
Power-On In-Rush Current...3 A
Allowable Drop-Out ........33 ms
Surge Protection
Video .................Low-capacitance Zener suppressor of 6.5 V,
1500 W
SensorNet/Manchester....Isolation transformer coupled, 2000 Vrms; PTC
resettable fuse protects transformer; TVS rated
at 5.6 V, 40 A, 0.1 J; 10 kA impulse rated gas
tube, 8/20 µsec impulse
RS-422/RS-485 .........Series resistors of 33 Ω; TVS rated at 5.6 V,
40 A, 0.1 J (Optima only)
Resettable fuse, 0.6 A, 60 V, 1.2 Ω; 90 V, 10 kA
impulse rated gas tube (Optima LT only)
Alarm Input ............Series resistors of 33 Ω; TVS rated at 5.6 V,
40 A, 0.1 J (Optima only)
Auxiliary Output..........100 V isolation form 1-C relay (Optima only)
Power Line .............TVS rated at 60 V, 250 A, 1.5 J; 10 kA impulse
rated gas tube, 8/20 µsec impulse
Camera
Imager ..................Interline transfer 1/4 in CCD array
Scanning System ..........2:1 interlace
Video Output .............1.0 Vp-p, 75 Ω composite
S/N Ratio ................48 dB (typical)
Horizontal Resolution .......470 lines at center
Minimum Illumination .......1.5 lux (20 IRE, AGC on)
Gain Control .............Automatic (AGC)
White Balance . . . . . . . . . . . . Through the Lens (TTL) Automatic Tracing
White Balance (ATWB)
NTSC
Pickup Device ...........768 (H) x 494 (V) pixels
Scanning ...............525 lines, 60 fields, 30 frames
Horizontal ..............15.734 kHz
Vertical ................59.9 Hz
PAL
Pickup Devices ..........752 (H) x 582 (V) pixels
Scanning ...............625 lines, 50 fields, 25 frames
Horizontal ..............15.625 kHz
Vertical ................50 Hz
Lens
Design...................Aspherical
Aperture .................f1.6
4mm..................47.0° (H) x 35.2° (V)
88 mm.................4.0° (H) x 3.0° (V)
Focal Length..............4 to 88 mm
Field of View Formulas
Horizontal View = (.8 x A)/B
Vertical View = (.6 x A)/B
A = distance from camera in meters or feet
B = zoom power (e.g. 1-242x)
Mechanical
Dimensions (H x D)
In-Ceiling Model
Total ................301 x 190.5 mm (11.9 x 7.5 in)
Above Ceiling .........207.4 x 190.5 mm (8.2 x 7.5 in)
Below Ceiling .........92.7 x 178 mm (3.65 x 7.0 in)
Integral Pendant Housing Model
Total ................303 x 243.5 mm (11.9 x 9.6 in)
Unit Weight
In-Ceiling Model .......2.5 kg (5.5 lbs)
Integral Pendant Housing Model
Indoor ..............2.7 kg (6.1 lbs)
Outdoor .............3.0 kg (6.6 lbs)
Environmental
Weatherproof Standard
Outdoor Models .........IP66/NEMA4
Operating Temperature
Indoor .................-10° to 50°C (14° to 122°F)
Outdoor ...............-40° to 50°C (-40° to 122°F)
Humidity ................0 to 95% RH (noncondensing)
Storage Temperature .......-20° to 65°C (-4° to 149°F)
Wind Loading .............Sustain winds of 240 km/hr (150 miles) when
properly installed and mounted (wall, pole, ceiling,
and over-the-roof mount with proper support).
(Outdoor model only)
Regulatory
Emissions . . . . . . . . . . . . . . . .FCC: 47 CFR Part 15,
Subpart B Class A
CE: EN55022 Class B
CE: EN6100-3-2
CE: EN6100-3-3
AS/NZS 3548, Class A
CISPR22
ICES-003
Immunity.................CE: EN50130-4
Safety ...................UL: UL1950
CUL: CSA 22.2 No. 950
CE: EN60950
IEC950