American Panel IC+ User manual

IC+
Intelligent Control and Alarm System
Cooler is Better!TM
American Panel Corporation
5800 S.E. 78th Street, Ocala, Florida 34472-3412
Phone: (352) 245-7055 Fax: (352) 245-0726
E-mail: [email protected]
Rev. 5/11/2020

Thank you, and congratulations on your purchase of an American Panel walk-in with Intelligent Control. We
take great pride in engineering and manufacturing each of our products. With the goal of providing the highest
accuracy and quality possible, our state-of-the-art manufacturing and quality control facility enables us to
continually explore new technologies so that we can provide you with the finest equipment in the industry.
Because of our commitment to your satisfaction, we have developed this Owner’s Manual to guide you through
the complete installation process, and to help you maintain your equipment properly. Familiarization and
compliance with this manual will ensure you years of trouble-free operation.
On occasion, situations can arise and will require the help of the factory, whether it be technical information,
service or replacement of parts. We have a highly trained Customer Service and Parts Department available to
help when these situations arise. We also offer a national network of service agencies that may be contacted for
warranty and out-of-warranty service.
When contacting the factory, please refer to the equipment serial number which can be located on the
identification plate positioned on the interior of the door frame.
Thank you once again for your purchase of American Panel equipment.
“Our reputation rests on the steadfast pursuit of your satisfaction”.
American Panel Corporation
5800 S.E. 78th Street, Ocala, Florida 34472-3412
Phone: (352) 245-7055 Fax: (352) 245-0726
E-mail: [email protected]
E78551

1
1Introduction and Features ................................................................................................................................ 2
2Temperature Monitoring .................................................................................................................................. 2
3Temperature Alarms ........................................................................................................................................ 2
4Panic Alarm ..................................................................................................................................................... 3
5Door Open Alarm ............................................................................................................................................ 3
6Door Frame Heater and Window Heater Control ............................................................................................ 3
7Electronically Controlled Light Switch and Automatic Light Off .................................................................. 4
8HACCP Recording........................................................................................................................................... 4
9Wi-Fi Connectivity and Remote Notification .................................................................................................. 4
10User Interface ................................................................................................................................................... 7
11Navigating the Menu ........................................................................................................................................ 8
12Restore the Default Settings ............................................................................................................................. 8
13Troubleshooting ............................................................................................................................................... 8
14Field Wiring ..................................................................................................................................................... 9
14.1Main Power........................................................................................................................................... 9
14.2Field Mounted Light Fixture .............................................................................................................. 10
14.3PANIC BUTTON FOR PARTITION DOOR .................................................................................... 11
14.43 WAY – 4 WAY Configuration and Remote Light Button .............................................................. 12
14.5Alarm Dry Contact ............................................................................................................................. 13
14.6Evaporator Fan Cut-Out Switch ......................................................................................................... 14
15Electrical Schematic ....................................................................................................................................... 15

2
1 IntroductionandFeatures
IntelligentControllerIC+wasdesignedbyAmericanPanelCorporationtocontrolvariouswalk‐indoordevicesandtomonitorthe
temperatureofthewalk‐incabinet.
IC+features:
TemperatureMonitoring
TemperatureAlarms
PanicAlarm(Optional)
DoorOpenAlarm
DoorandWindowFrameHeaterControl
ElectronicallyControlledLightSwitchandAutomaticLightOff
HACCPRecording
Wi‐FiConnectivityandRemoteNotification
IntuitiveUserInterface
BatteryBackup
AdaptiveSettings
2 TemperatureMonitoring
IC+monitorsthewalk‐incabinettemperatureviaaprobemountedinthewarmestpartofthecabinetwhichisnearthedoor.The
alarmdelaywillensurethatthealarmdoesnotgooffduringnormaldooropenings.
Foranaccurateairtemperaturereadingdonotrestricttheairflowoverthetemperatureprobe.Tomonitortheairtemperatureata
differentlocationanextendedtemperatureprobeisavailableforpurchase.
Ifequippedwithanextratemperatureprobe,IC+willmonitorthetemperatureattwolocationsorthetemperatureoftwodifferent
cabinets
Oneprobedisplay Twoprobesdisplay
3 TemperatureAlarms
Ifthetemperatureinsidethewalk‐incabinetgoesabovethehighalarmthresholdorbelowthelowalarmthreshold,the
temperaturereadingonthedisplaywillblinkindicatingthatthealarmtimedelayhasbeentriggered.Ifthetemperaturedoesnot
returntonormallimitswithinthedelaytime,thebuzzerwillgooffandthedisplaywillshowthealarmmessagealternatingwiththe
temperaturereading.IfIC+isconnectedtothelocalWi‐Finetwork,itwillsendanalarmmessageviae‐mail.
Hightemperaturealarm Lowtemperaturealarm
Thebuzzercanbesilencedbypressingthealarmmutebutton.
Thealarm’ssetpointsanddelaytimesarefullyprogrammabletouser’sneeds.

3
Defaultsetpoints:
HighAlarmTriggerPoint (AH) LowAlarmTriggerPoint
(AL)
AlarmDelay
(AD)
Cooler 45oF 32oF
40Minutes
Freezer 20oF ‐25oF
BeerCooler 34oF 30oF
4 PanicAlarm
PanicalarmisanoptionalfeatureonAmericanPanelwalk‐ins.IfequippedwithaPanicalarm,thewalk‐incabinetwillhavean
illuminatedredpushbuttoninstalledontheinteriorofthecabinetandanalarmbuzzerwithLEDlightinstallontheexteriorofthe
cabinet.
Totriggerthealarm,pushtheilluminatedredbuttonmountedinsidethewalk‐incabinetandanaudio/visualalarmbuzzerwill
illuminateandsoundthealarmandtheIC+controllerwilldisplaythepanicalarmmessage.IfIC+isconnectedtothelocalWi‐Fi
network,andsetupassuch,itwillsendanalarmmessageviae‐mail.
Toclearthealarm,pushandreleasethepanicbuttontodepressandthenpressthealarmmutebuttonontheIC+.
5 DoorOpenAlarm
IC+controllersmonitorthestatusofthedoor.Ifthedoorisnotfullyclosedorifleftopenformorethanthepre‐settime(5minutes
bydefault)theIC+controllerwilldisplaythealarmmessageandtheonboardbuzzerwillsound.IfIC+isconnectedtothelocalWiFi
network,itwillsendanalarmmessageviae‐mail.
Close the door to reset the alarm.
6 DoorFrameHeaterandWindowHeaterControl
ICcontrollerswitchesonthedoorframeheaterandthewindowheater(ifsoequipped)whentheairtemperaturedrops
belowthepresetthresholdof45oFandthencyclesthemonandoffbasedonatimecycle.Oncoolers,bydefault,theheatersstays
onfor35%ofa6‐minutecycleandthenstaysofffor65%,thecyclewillrepeat.Thealarm’ssetpointsanddelaytimesarefully
programmabletouser’sneeds.
Defaultsetpoints:
HeatersOn(Pr) HeatersOff Heatersswitchedonbelow:
(tP)
Cooler 35%ofa6‐minutecycle 65%ofa6‐minutecycle
45oFFreezer 100%ofa6‐minutecycle 0%ofa6‐minutecycle
BeerCooler 65%ofa6‐minutecycle 35%ofa6‐minutecycle

4
7 ElectronicallyControlledLightSwitchandAutomaticLightOff
ThecabinetlightcanbeswitchedonfromtheIC+controllerviatheintegratedlightbuttonorsimplybyopeningthedoor.TheIC+
willdisplayalightbulbicontoindicatethatthelightisoninsidethecabinet.
TheAutomaticLightOfffeatureofIC+enablestheusertosaveenergy.Theamountoftimethelightwillstayoncanbesetfrom1
minuteto60minutesorcanbesetformanualshutoffonly.Asdefault,theautomaticlightofffeatureisdisabled.
PushtheintegratedlightbuttononIC+toturnthelightoffmanually.
Back‐to‐backlightcontrolisprovidedasanoptionalfeature.
NOTE:WhenusinganoccupancysensorinconjunctionwithIC+,theAutomaticLightOfffeaturemustbeenabled.
8 HACCPRecording
IC+controllerrecordstheairtemperatureatpresettimeintervalswhichbydefaultissetto30minutes.Inadditiontotheair
temperatureIC+recordsallthealarmsanddooropenings.
TheHACCPdatacanbepreviewedontheIC+display.Todoso,pushtheMENUbuttonandgotoHACCPPreview→PreviewEvents,
selectanyoftheeventsinthelisttoviewthedetailsrelatedtothatevent.
TodownloadthedataviaUSB,insertaUSBdriveintheUSBportandfollowthepromptsonthedisplay.
IfIC+controllerisconnectedtoaninternetenabledWi‐Finetwork,itcanbesetuptosendperiodice‐mailscontainingtheHACCP
data,see“Wi‐FiConnectivityandRemoteNotification”chapterofthismanual.Anon‐demandHACCPe‐mailoptionisavailablein
theIC+menuatHACCPPreview→SendEmailHACCP.
Theretrieveddatawillbeina.csvformatfilethatcanbeopenedwithMicrosoftExcelorothercompatiblesoftware.Thenameof
thefilewillincludethedateandtimewhenthefilewasretrieved.
SampleHACCPfile:
9 Wi‐FiConnectivityandRemoteNotification
IC+isequippedwithaWi‐FimodulewhichenablesittoconnecttothelocalWi‐Finetworkforthepurposeofsendingremote
notificatione‐mailsforallthealarmsandsendinge‐mailscontainingHACCPdataattachments.
FollowthestepsbelowtoconnecttheIC+toWi‐Fiandtosetitupforremotenotifications:

5
IC+ Setup Tool
1. IfmultipleIC+controllersaretobeconnectedtothesameWi‐Finetwork,youmustsetadifferentserialnumberforeach
controllerinordertodifferentiatebetweenthem.Todoso,entertheIC+menu,gotoSettings(defaultpasscodeis7055)→
About→SerialNumber.Whendonepress“MENU”buttonrepeatedlytoexitthesettingsmenu.
Note:Whenassigningdifferentserialnumbersforeachcontroller,makeanoteoftheserialnumberswiththelocationfor
laterreference.
2. OnaBluetoothenableddevicedownloadIC+SetupToolapp,availableforIOSandAndroiddevices.
3. EnablethelocationfeatureonyourdeviceandopenIC+SetupToolapp.
IC+controllerwillneedane‐mailaccountsetupsoitallowsIC+toaccessitandsende‐mails.Forthispurpose,AmericanPanel
CorporationprovidesagenericGmailaccount[email protected];however,werecommendreplacingthisaccountwithanew
onethatisownedandmaintainedbytheenduser.
AmericanPanelCorporationisnotresponsibleforthefunctionalityofthegenericaccount,icpluswa[email protected]andit
reservestherighttomodifyordiscontinuetheaccountwithoutadvancenotice.
8.OutgoingEmailServerSetup
Inthe“Selectoutgoingemail”chooseoneoftheavailableoptions,fillintherequiredinformation,and
press“SaveChanges”whendone.
Availableoptions:
Default–selectthisoptionifyouchoosetokeepthegenericemailaccountprovidedbyAmerican
PanelCorporation.NoSMTPserversettingrequired.
or
Custom–selectthisoptionifyouwishtoconfiguretheSMTPsettingsforapreferredemailaccount
or
Gmail,Yahoo,orAOL–selectthisoptiontoconfiguretheSMTPsettingsforapreferredexistingemail
accountatoneoftheemailserversmentionedabove
Note:WhenusingaYahooorAOLyoumustgenerateanapppassword,youcandosofromthe
securitysettingsoftheYahooorAOLemailaccount,andthenenterthatpasswordinthePassword
field,seefigureontheleft.
Note:WhenusingGmail,youmustturnonaccesstolesssecureappsfromthesecuritysettingsof
theGmailaccount.OnlyafterthatIC+willbeabletoaccesstheaccount.
4.Press“ScanforDevices” 5.Selectfromthelist 6.DefaultPasscodeis“7055” 7.Press“OutgoingEmail
ServerSetup”

6
9.UserEmailTemplatesSetup
HighPriorityAlarms:PowerFailure,PanicAlarm,DefectiveTemp.Probe
MediumPriorityAlarms:HighTemp.Alarm,LowTemp.Alarm
LowPriorityAlarms:DoorOpenAlarm
Note:ICplussupportsupto5emailrecipients.
TIP:ToreceivealarmsviaSMStextmessagesuseemailtotextgateway.Inthe“EnterEmailAddress”fieldatstep11,seeabove,
enterthe10‐digitcellphonenumberyouwantthealarmstobetextedtofollowedbytheemaildomaincorrespondingtothe
cellphonecarrier.Forexample,toreceivetextsonaT‐Mobilenumber(123)4567890,enter[email protected].Tofindout
theemaildomainforyourspecificcarriersearchontheinternetfor“Emailtotextgatewaylist”orcontactyourcellphonecarrier.
14.InternetWi‐FiSetup
ChooseaWi‐Finetworkfromthelist,enterthepassword,andpressconnect.
10.Press“AddNewUser
Email”
11Entertheemailaddressof
thepersonthatwillreceivethe
notifications.
12.Selectthetypeofalarmsor
emailsthatthisuserwill
receive.Press“SaveChanges”
whendone.
13.Sethowoftentoreceive
theHACCPreportemail.

7
10 UserInterface
CURRENTDATE
ANDTIME
CURRENTCABINET
TEMPERATURE
ICONINDICATINGTHAT
THELIGHTINSIDETHE
CABINETISON
STEADYWI‐FIICONINDICATESTHAT
THECONTROLLERISCONNECTEDTO
THELOCALNETWORK
UNITOFMEASURE,oFINDICATES
DEGREESFAHRENHEIT
WALK‐INCABINET
TYPE
USBPORT
LIGHTBUTTON
ALARMMUTEBUTTON
MENUNAVIGATION
BUTTONS

8
11 NavigatingtheMenu
ToaccessIC+MainMenu,pushtheMENUbuttonthenscrolltothedesiredoptionusingtheupanddownbuttonsandpressENTER
buttontoconfirmtheselection.Togotothepreviousscreen,presstheMENUbutton.
TheSettingsMenucanbeaccessedfromtheMainMenu,thedefaultpasscodeis7055.Tochangeanyparameter,scrolltoitand
pressENTERtoconfirmyourselection.Useupanddownbuttonstochangetheparameter,whendonepressENTERtoconfirmthe
newparameter.
12 RestoretheDefaultSettings
Torestorethedefaultsettingspressandholdupanddownbuttonsforapproximately10seconds,followtheprompts.
Note1:Restoringthedefaultsettingswillresettheaccesspasscodeto7055.
Note2:RestoringthedefaultsettingswillnotaffecttheWI‐FIsettings.
13 Troubleshooting
Issue PossibleCause Action
Thetemperaturereadingisflashingonand
off.
IC+controllerdetectedcabinet
temperaturehigherorlowerthanthe
presetlimits.Theflashingnumberisthe
measuredtemperatureinsidethe
cabinet.Thealarmwillnotgooffuntilthe
alarmdelaytimeexpires.
Makesureallthedoors are closedand
checkthetemperatureafterfewminutes
tomakesureitgoesbacktothenormal
range.
TheIC+beepsanddisplaysthehigh
temperaturealarmmessage.
Ifthehighairalarmwentoff,the
temperatureinsidethecabinetisabove
thepresetlimit.Theflashingnumberis
themeasuredtemperatureinsidethe
cabinet.
Tosilencethealarm,pressthealarm
mutebutton.Checkalldoorstobe
closed,checkthetemperaturesettingat
thethermostat(typicallylocatedonthe
evaporatorcoil)andmakesurethe
refrigerationsystemworksproperly.
Iftheissuepersists,contacta
refrigerationtechnician.
TheIC+beepsanddisplaysthelow
temperaturealarmmessage.
Ifthelowairalarmwentoff,the
temperatureinsidethecabinetisbelow
thepresetlimit.Theflashingnumberis
themeasuredtemperatureinsidethe
cabinet.
Tosilencethealarm,pressthealarm
mutebutton.Checktomakesurethe
refrigerationsystemworksproperly,
checkthetemperaturesettingatthe
thermostat(typicallylocatedonthe
evaporatorcoil).Iftheissuepersists,
contactarefrigerationtechnician.
Condensationonthedoorframeand/or
thewindow.
Thesettingforthedoorheateristoolow. Increasethepercentagethedoorheater
stayson.Todoso,gotoMENU→Settings
(7055defaultpasscode)→DoorHeater
Setup→PrecentageOn.Iftheissue
persists,contactatechnician.

9
14 FieldWiring
Note:Allfieldwiringmustbedonebyalicensedelectricianincompliancewiththenationalandlocalelectricalcodes.
Note:Electricianmustprovideseal‐offsateveryconduitentryonthewarmandcoldsideofpanels.Sealinsideandaroundall
conduitswherepassingthroughpanels.
WireColorCode(fieldwiringonly)
Black(1ea)andWhite(1ea)–Mainpowerwires,terminatedinsidethevaporprooflightfixtureorstubbedout.Electricianwill
providethegroundwire,seeelectricalschematicatchapter14.1ofthisdocument.
Red(1ea)–Outputtofieldmountedlightfixturewire,terminatedinsidethevaporprooflightfixtureorstubbedout,seeelectrical
schematicatchapter14.2inthisdocument
Brown(1ea)–Outputtoremotebuzzerwire,terminatedinsidethevaporprooflightfixtureorstubbedout,seeelectricalschematic
atchapter14.3inthisdocument
Blue(1ea)andYellow(1ea)–3WAY/MultiWayconfigurationwires,terminatedinsidethevaporprooflightfixtureorstubbedout,
seeelectricalschematicatchapter14.4ofthisdocument
Whitewithbluestripe(2ea)–alarmdrycontactwires,terminatedintherectangularconnectionboxlocatednexttothevapor
prooflightfixture,orstubbedout,seechapter14.5ofthisdocument.
Purple(2ea)–evaporatorfancutoutswitch(closedwhenthedoorisclosed),terminatedintherectangularconnectionboxnextto
thevaporprooflightfixture,orstubbedout,seechapter14.6ofthisdocument.
14.1 MainPower
Makealltheconnectionsinsidethevaporprooflightfixturelocatedonthedoorframeinsidethewalk‐in.
Ifanelectricalstub‐outconstructionwasrequested,alltheconnectionwireswillbestubbed‐outthrutheceiling.Inthiscase,the
fieldconnectionswillbemadeinajunctionboxprovidedbytheinstaller.
ELECTRICIAN MUST
SEAL THE CONDUIT AT
BOTH ENDS!

10
14.2 FieldMountedLightFixture
ELECTRICIAN MUST
SEAL THE CONDUIT AT
BOTH ENDS!

11
14.3 PANICBUTTONFORPARTITIONDOOR
ELECTRICIAN MUST
SEAL THE CONDUIT AT
BOTH ENDS!

12
14.4 3WAY–4WAYConfigurationandRemoteLightButton
This configuration is typical to cabinets that have multiple doors. The user will be able to turn on and off the
light from any door.
ELECTRICIAN MUST
SEAL THE CONDUIT AT
BOTH ENDS!

13
14.5 AlarmDryContact
Lowvoltagewhitewithbluestipewiresarelocatedinsidetherectangularjunctionbox,nexttothevaporprooflightfixture.
ELECTRICIAN MUST
SEAL THE CONDUIT AT
BOTH ENDS!

14
14.6 EvaporatorFanCut‐OutSwitch
Thepinkwiresarelocatedinsidetherectangularconnectionbox,nexttothevaporprooflightfixture.
ELECTRICIAN MUST
SEAL THE CONDUIT AT
BOTH ENDS!

15
15 ElectricalSchematic

American Panel Corporation
5800 S.E. 78th Street, Ocala, Florida 34472-3412
Phone: (352) 245-7055 Fax: (352) 245-0726
E-mail: [email protected]
Table of contents
Popular Control System manuals by other brands

CAME
CAME 001G3750 installation manual

Organomation Associates
Organomation Associates MULTIVAP 118 instruction manual

Motorline professional
Motorline professional MPIE10 installer and user manual

Carefree
Carefree BT12 user guide

Lutron Electronics
Lutron Electronics Stanza installation instructions

Tume
Tume AgroCont manual