LED INDICATORS
LED Colour Description
POWER 1 / 2 Blue DC input present on power 1 / 2
ALARM Red Unit in alarm condition
SFP LINK/ACT Green SFP link present (ashes with data
trac activity)
POE 1-8 Yellow PoE is being delivered on the port
RJ45 LINK/ACT Green Ethernet link present (ashes with
data trac activity)
POWER
+
-
Warning
Do not exceed the rated voltage
Refer to product label
Power
2
Alarm & Contact Output
Relay Output (400V @ 0.1A Max)
DEVICE RESET PROCEDURE
CONNECTING TO THE SWITCH
Alarm Out
To access the full software user guide for this product
please visit the product page using the QR code
opposite or the direct link below:
amg-support.com/AMG570-8G-3S_Series
Web GUI
Default IP Address: 192.168.1.101
Username: admin
Password: admin
Console CLI
USB-A to USB-C Cable 115200,8,N,1
With the unit powered up press and
hold the RESET button for 6 seconds,
and then release it. The unit will
reboot and restore the factory default
settings.
+
-
Power
1
Model Type Voltage
Non-PoE Models 12-56 VDC
PoE Models 48-56 VDC*
Model Type Power
All Models 10W Max*
*Excludes PoE Load
*50V or above recommened for 30W PoE
52V or above recommended for >60W PoE
Warning
Check Polarity Before Powering
No Reverse Polarity Protection
Contact In
Contact Out
Common
CONTACT INPUTS & OUTPUTS
POE CAPABILITIES
Example part code:
AMG570-2GBT-4GAT-2G-3S-P300
Characters PoE Standard Supported
None Non-PoE Model
AT IEEE 802.3at 30W Per Port
BT IEEE 802.3bt 60/90W Per Port
Characters PoE Budget
P240 240W Max
P300 300W Max
P360 360W Max
Check the product label to determine
the PoE power supported on each port
and the units total maximum PoE budget.
IEEE 802.3at Ports
Type 1 & 2 PoE supported
Mode A PSE only
IEEE 802.3bt Ports
Type 1, 2, 3 & 4 PoE supported
Mode A and/or Mode B PSE
Ensure PSU size used is at
least equal to the maximum
PoE budget gure.
Contact Input
Dry Contact (No Voltage)
ICOM ALM COM OCOM
AMG570 Interface Circuit
Optical
Isolation