Amperes ZS5062 User manual

Thank you for choosing another quality product from Amperes Electronics.
After much improvements made to the earlier models, Amperes ZS5062 and ZS5122 finally rolled out with better
features and outlooks.
The original features of emergency paging microphone input port and remote triggering are maintained. However a
priority overtaking LED is added to the front panel to alert the user that paging from remote is active and thus the
BGM zone selected has been bypassed.
With this new product, you are assured that we live up to our policy, ie. continuous improvement to give you the
products that are contemporary and with better value without increment in cost.
Although it is not difficult to install this unit, a brief reading of the manual is truly recommended to avoid any
misconnection as well as to explore the potential usage of the product to its maximum.
VER 1 / 2014
SPEAKER ZONE SELECTOR
21 3 54
SPEAKER ZONE SELECT
6 7 8 9 10 1211
ZS 5122 amperes
OVERRIDE
ALL CALL
SPEAKER ZONE SELECTOR
OVERRIDE
21 3 54
SPEAKER ZONE SELECT
6
ALL CALL
ZS 5062 amperes

1. BGM ZONE OVERRIDING INDICATOR
The LED shall lit if remote paging microphone is active and is overriding the local BGM zone selection. This
is active if Amperes PM 1060 paging is used or any other paging microphone console with Priority output signal.
3. FRONT PANEL ZONE SWITCHES - ZONE 1 TO 6
Switching for zone 1 to 6.
Parts Identifications
SPEAKER ZONE SELECTOR
21 3 54
SPEAKER ZONE SELECT
6 7 8 9 10 1211
ZS 5122 amperes
OVERRIDE
ALL CALL
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 1 TO 6
ZONE SELECTOR
ZS 5122
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 7 TO 12
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
ZREMOTE SELECTREMOTE SELECT
A B
RS485
100V
AMP 4AMP 1
100V
ZON2
100V
COM
100V
100V
COM
COM
ZON1 AMP 2
COM
100V
COM
COM
AMP 3
100V
ZON3
COM
ZON6
COM
COM
ZON4
100V
COM
100V
AMP 5
100V
100V
AMP 6
COM
ZON5
COM
100V
COM
ZON12
AMP 7
100V
100V
AMP10
ZON8
100V
100V
ZON7
COM
COM
COM
AMP 8
100V
100V
100V
COM
COM
COM
AMP 9 ZON9
100V
100V
COM
COM
COM
ZON10 AMP11
100V
100V
100V
COM
COM
ZON11 AMP12
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
1-Z7
2-Z8
3-Z9
4-Z10
5-Z11
6-Z12
7-24V
8-COM
UNIT ADD
ON
8
4
21 ZONE 1 TO 6 ZONE 7 TO 12
Quality Product From
AMPERES ELECTRONICS
2
10
9
3
6
1
511 12
6. EMERGENCY OVERRIDE TERMINAL
8
2. ALL CALL SWITCH
All zones will be activated by pressing this switch, regardless of any inactive zone.
5. DC SUPPLY INPUT PORT
4. FRONT PANEL ZONE SWITCHES - ZONE 6 TO 12
Switching for zone 7 to 12 for ZS5122 only.
4
Front View
Rear View
24V DC supply is required to operate this unit. Ensure polarity is correctly terminated to the port. It is
recommended that supply with 1Arating of regulated source is used.Amperes PS9400 is recommended as
a DC supply source to your installation.
PAGE 2 ZS5062 / ZS5122 6 / 12 CHANNEL SPEAKER ZONE SELECTOR
External switch ( eg. fr emergency paging mic with dry contact ) can be connected here, which shall trigger the
built in relay when pressed. This shall then provide a dry contact in which would enable the installer to apply
several functions such as providing 24V DC output for volume controller overriding purpose, trigger external
device or link to BAS system, etc.
7

8. UNIT ADDRESS DIP SWITCH
9. REMOTE SELECT PORT - Z1 TO 6
11. REMOTE SELECT PORT - Z7 TO 12
Similiar function as Part 9 but only available for ZS5122.
This is to connect to remote paging mic ( PM series ) or Data Decoder ( TD Series ) for remote zone triggering.
Upon triggering the zone via this port, it shall override the locally selected zones. External triggering switches
or other mades of paging microphone can utilise this facility provided -ve triggering method is used.
Parts Identifications
PAGE 3
ZS5062 / ZS5122 6 / 12 CHANNEL SPEAKER ZONE SELECTOR
When it is required to be linked to Amperes PMX II software for monitoring purpose, the unit / units are
required to be addressed. Binary code addressing is used in setting the unit’s ID.
10. AMPLIFIER - ZONE OUTPUT CONNECTORS (ZONE 1 TO 6)
Outputs from amplifiers are connected to these terminalsand speaker zoning is configured to the
respective unit of amplifier. The user has the flexibility to configure the zoning system as each zone comes
with single amplifier output connection.
Please observe polarity when terminating the amplifier / speaker zones and ensure that each zone is over-
loaded ( less than 500 W rms ).
12. AMPLIFIER - ZONE OUTPUT CONNECTORS (ZONE 7 TO 12)
Outputs from amplifiers are connected to these terminalsand speaker zoning is configured to the
respective unit of amplifier. The user has the flexibility to configure the zoning system as each zone comes
with single amplifier output connection.
Please observe polarity when terminating the amplifier / speaker zones and ensure that each zone is over-
loaded ( less than 500 W rms ).
7. RS485 DATA PORT
RS485 data port is used to interface with other Amperes products, to enable simpler cabling or interconnec-
tion works. Alternatively, it can be linked to PC for firmware upgrade. A USB-RS485 converter shall be
required for this purpose.
Please refer to section ‘ Firmware Upgrading’ to perform the Firmware update process.

REMOTE ZONE SWITCHES
Z2
Z6
Z1
24 DC
ZONE 1
FROM POWER
AMPLIFIER 1
-VE (Pin8)
POWER AMP 2
24 DC
AMPERES PM1120
PAGING MICROPHONE
N+2 CORE FLEXIBLE CABLE
N= NUMBER OF ZONE
Cat5 Cable
Cat5 Cable
REAR VIEW OF PM1120
AUDIO OUT
(TWISTED PAIR SCREEN) PIN 1~12 : ZONE 1 ~ 12
PIN 13 : GND, -VE
PIN 14 : PRIORITY
PIN 15 : +24V DC
The diagram above shows an installation of a 2 zone system with remote triggering e
mploying external switches. ( this
is optional ). In this case, zone triggering can be made from remote location.
Note :
The sample connections shown are using a single
unit of either ZS5122 or ZS5062 in a small scale
installation. ie. small number of zone outputs.
Assumptions made are that :
1. Volume control overriding facilities are done
separately. ( refer example on page 6)
2. Paging or background music is transmitted only
to the zone selected. (Not uninterrupted
paging system )
3. Power amplifier unit 1 is to serve zone 1 and 2
The illustration below shows a zone selector
connected to the Amperes PM1120 desktop
paging microphone. This shall provide a better
zone selection than the above configuration.
T
wo way zone selection can be done, either from
the PM1120 or via the front panel switches of the
zone selector, with PM1120 has a priority over
the former.
Example :
With front panel switches 1 and 2 active, and the
user wishes to page zone 3 only
, activation of
zone 3 from PM1120 shall override zone 1 and 2.
Upon releasing zone 3 from PM1120, zone 1 and
2 shall then return to its previous state.
POWER AMP 1
POWER AMP 1
Triggering any zone via the remote port shall override the previously selected zones. No Priority connection
is required.
No connection required for Pin 14 to zone selector
Single Unit Installation With Remote Select
PAGE 4 ZS5062 / ZS5122 6 / 12 CHANNEL SPEAKER ZONE SELECTOR
AMPLIFIER INPUTS - ZONE OUTPUTS FOR
ZONE SELECTOR
ZS 5122
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
ZREMOTE SELECT
A B
RS485
100V
AMP 4AMP 1
100V
ZON2
100V
COM
100V
100V
COM
COM
ZON1 AMP 2
COM
100V
COM
COM
AMP 3
100V
ZON3
COM
ZON4
100V
COM
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
UNIT ADD
ON
8
4
21 ZONE 1 TO 6
Quality Product From
AMPERES ELECTRONICS
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 1 TO 6
ZONE SELECTOR
ZS 5122
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
ZREMOTE SELECTREMOTE SELECT
A B
RS485
100V
AMP 4AMP 1
100V
ZON2
100V
COM
100V
100V
COM
COM
ZON1 AMP 2
COM
100V
COM
COM
AMP 3
100V
ZON3
COM
ZON6
COM
COM
ZON4
100V
COM
100V
AMP 5
100V
100V
AMP 6
COM
ZON5
COM
100V
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
1-Z7
2-Z8
3-Z9
4-Z10
5-Z11
6-Z12
7-24V
8-COM
UNIT ADD
ON
8
4
21 ZONE 1 TO 6 ZONE 7 TO 12
Quality Product From
AMPERES ELECTRONICS
ZONE 2

amperes
MX2222
PO W E R
OFF SEL E C T
TUN E R
CD
CAS S
OFF
MA S T E R
MUS I C S O U R C E
SIG IN
BAS S
MAXMIN
EXT IN P U T
MAX MAXMIN
SO U R C E
MIN
SIG IN
CHIM E MIX E R TREBL E
MAXMIN
TON E C T R L
CH5 CH6CH4
SIG INSI G IN SIG IN
MAXMIN MAXMIN MIN
CH3CH1 CH2
SIG INSIG IN
MAXMIN MAXMIN MAXMIN MAX
AUX
SIG IN
a sample of system with TD6240 zone decoder and few zone selectors
PD2800
Paging Mic
TD6240 Data
decoder MX2222 Mixer
Power Amplifiers
ZS5122 Zone Selectors
Zone 1 to 12
Zone 13 to 24
Zone 25 to 36
P IN 8 -C O M
P IN 7 -2 4 V
P IN 6 -Z 6
P IN 5 -Z 5
P IN 4 -Z 4
P IN 3 -Z 3
P IN 2 -Z 2
P IN 1 -Z 1
1
RJ45 Pin configurations
Note that All Call and PR from remote mic shall not be required
to TD6240 Unit 1
Trigger Port 1
to TD6240 Unit 1
Trigger Port 2
to TD6240 Unit 1
Trigger Port 3
to TD6240 Unit 1
Trigger Port 4
to TD6240 Unit 2
Trigger Port 1
to TD6240 Unit 2
Trigger Port 2
For Zone 1 to 12
For Zone 13 to 24
For Zone 25 to 36
ALL CALL to all units can be triggered from paging mic.
Pressing ALL CALL button from zone selector front panel shall only trigger all
zones of the particular unit only. And the connection Z PR must link.
Use EP1200A to make ALL CALL to all ZS installed - refer to page 6.
Switching signal
audio
Multiple Units Installation ( Cascading )
PAGE 5
ZS5062 / ZS5122 6 / 12 CHANNEL SPEAKER ZONE SELECTOR
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 7 TO 12
REMOTE SELECT
COM
ZON12
AMP 7
100V
100V
AMP10
ZON8
100V
100V
ZON7
COM
COM
COM
AMP 8
100V
100V
100V
COM
COM
COM
AMP 9 ZON9
100V
100V
COM
COM
COM
ZON10 AMP11
100V
100V
100V
COM
COM
ZON11 AMP12
ZONE 7 TO 12
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 7 TO 12
REMOTE SELECT
COM
ZON12
AMP 7
100V
100V
AMP10
ZON8
100V
100V
ZON7
COM
COM
COM
AMP 8
100V
100V
100V
COM
COM
COM
AMP 9 ZON9
100V
100V
COM
COM
COM
ZON10 AMP11
100V
100V
100V
COM
COM
ZON11 AMP12
ZONE 7 TO 12
SPEAKER ZONE SELECTOR
21 3 54
SPEAKER ZONE SELECT
6 7 8 9 10 1211
ZS 5122 amperes
OVERRIDE
ALL CALL
SPEAKER ZONE SELECTOR
21 3 54
SPEAKER ZONE SELECT
6 7 8 9 10 1211
ZS 5122 amperes
OVERRIDE
ALL CALL
SPEAKER ZONE SELECTOR
21 3 54
SPEAKER ZONE SELECT
6 7 8 9 10 1211
ZS 5122 amperes
OVERRIDE
ALL CALL
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 7 TO 12
REMOTE SELECT
COM
ZON12
AMP 7
100V
100V
AMP10
ZON8
100V
100V
ZON7
COM
COM
COM
AMP 8
100V
100V
100V
COM
COM
COM
AMP 9 ZON9
100V
100V
COM
COM
COM
ZON10 AMP11
100V
100V
100V
COM
COM
ZON11 AMP12
ZONE 7 TO 12
ZONE SELECTOR
ZS 5122
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
Z
A B
RS485
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
UNIT ADD
ON
8
421
Quality Product From
AMPERES ELECTRONICS
REMOTE SELECT
ZONE 1 TO 6
ZONE SELECTOR
ZS 5122
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
Z
A B
RS485
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
UNIT ADD
ON
8
421
Quality Product From
AMPERES ELECTRONICS
REMOTE SELECT
ZONE 1 TO 6
ZONE SELECTOR
ZS 5122
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
Z
A B
RS485
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
UNIT ADD
ON
8
421
Quality Product From
AMPERES ELECTRONICS
REMOTE SELECT
ZONE 1 TO 6
This manual suits for next models
1
Table of contents
Other Amperes Recording Equipment manuals