Amperes ZS5121 User manual

ZS
ZS
5601 6 Channel Speaker Zone Selector
5121 12 Channel Speaker Zone Selector
amperes ... the emerging preference
www.ampereselectronics.com
INSTRUCTION MANUAL

After much improvements made to the earlier models, Amperes ZS5601 and ZS5121 finally rolled
out with better features and outlooks.
The original features of emergency paging microphone input port and remote triggering are
maintained. However a priority overtaking LED is added to the front panel to alert the user that
paging from remote is active and thus the BGM zone selected has been bypassed.
With this new product, you are assured that we live up to our policy, ie. continuous improvement to
give you the products that are contemporary and with better value without increment in cost.
Although it is not difficult to install this unit, a brief reading of the manual is truly recommended to
avoid any misconnection as well as explore the potential usage of the product to its maximum.
PAGE 2
PARTS IDENTIFICATION
1. BGM ZONE OVERRIDING INDICATOR
The LED shall lit if remote paging microphone is active and is overriding the local BGM zone selection. This is
active if Amperes PM 1060 paging is used or any other paging microphone console with Priority output signal.
2. FRONT PANEL ZONE SWITCHES - ZONE 1 TO 6
Switching for zone 1 to 6. They can be configured as zone 1 to 5 with Sub group switch. Refer to Application
Example on how to do this.
TIONS
Congratulations on the purchase of your new Amperes ZS 5601/ 5121
Speaker Zone Selector Panel.
PLEASE OBSERVE POLARITY WHEN CABLING
AMP 1
AMPERES ELECTRONICS
Quality Product From
ZS 5121
DC 24V
+RELAY
TRIG CONT
RELAY
100V
AMPLIFIERINPUTS-ZONEOUTPUTSFORZONE1TO6
COM
AMP 4
COM
ZON2
100V
COM
100V
100V
COM
COM
ZON1 AMP 2
100V
COM
100V
COM
AMP 3
100V
ZON3
100V
COM
COM
ZON5
COM
ZON4
100V
100V
AMP 5
COM
100V
AMP 6
COM
100V
ZON6
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 7 TO 12
AMP11
COM
AMP 8
100V
100V
ZON7
COM
COM
100V
AMP 7
COM
ZON9
100V
100V
COM
COM
AMP 9
100V
ZON8
100V
100V
100V
COM
COM
COM
ZON10AMP10
COM
100V
100V
100V
COM
COM
ZON11 AMP12 ZON12
1234
5678910
PIN 8-COM
PIN 7-+24V
PIN 6-Z6
PIN 5-Z5
PIN 4-Z4
PIN 3-Z3
PIN 2-Z2
PIN 1-Z1
PIN 8-COM
PIN 7-+24V
PIN 6-Z12
PIN 5-Z11
PIN 4-Z10
PIN 3-Z9
PIN 2-Z8
PIN 1-Z7

PAGE 3
3. FRONT PANEL ZONE SWITCHES - ZONE 7 TO 12
Switching for zone 7 - 12 for ZS5121 only. Refer to Application example for grouping.
4. ALL CALL SWITCH
All zones will be activated by pressing this switch, regardless of any inactive zone.
5. DC SUPPLY INPUT PORT
24V DC supply is required to operate this unit. Ensure polarity is correctly terminated to the port. It is
recommeded that supply with 1A rating of regulated source is used. Amperes PS9400 is recommended as
a DC supply source to your installation.
6. EMERGENCY OVERRIDE TERMINAL
External switch ( eg. fr emergency paging mic with dry contact ) can be connected here, which shall trigger
the built in relay when pressed. This shall then provide a dry contact in which would enable the installer to
apply several functions such as providing 24V DC output for volume controller overriding purpose, trigger
external device or link to BAS system, etc.
7. REMOTE SELECT PORT - Z1 TO 6
8. AMPLIFIER - ZONE OUTPUT CONNECTORS (ZONE 1 TO 6)
Outputs from amplifiers are connected to these terminals and speaker zoning is configured to the
respective unit of amplifier. The user has the flexibility to configure the zoning system as each zone comes
with single amplifier output connection.
Please observe palarity when terminating the amplifier / speaker zones and ensure that each zone is over
overloaded ( less than 400 W rms )
9. REMOTE SELECT PORT - Z7 TO 12
Similiar function as Part7 but only available for ZS5121
10. AMPLIFIER - ZONE OUTPUT CONNECTORS (ZONE 7 TO 12)
Similiar to Part 7 but only available for model ZS 5121
PARTS IDENTIFICATION
ampereselectronics.com
This is to connect to remote paging mic ( PM series ) or Data Decoder ( TD Series ) for remote zone trigger-
ing. Upon triggering the zone via this port, it shall override the locally selected zones. External triggering
switches or other mades of paging microphone can utilise this facility provided -ve triggering method is used.

MO
AMP 2
REMOTE ZONE SWITCHES
Z2
Z6
Z1
24 DC
AMP 1
V0
ZON1
V
0
M
O
V
0
M
O
SPEAKER Z3
SPEAKER Z2
SPEAKER Z1
FROM POWER
AMPLIFIER 1
POWER AMP 2
ZON3
V
0
ZON2 AMP 3
MO
V
0
V0
M
O
AMP 4 ZON4
MO
V
0
M
O
V
0
MO
AMP 6AMP 5 ZON5
M
O
V
0
V
0
MO
V
0
ZON
V
0
MO
SZ 5121
another quality product from
amperes electronics
TRIG
+- CONT
DC 24V RELAY RELAY REMOTE SELECT
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 1 TO 6
-VE (Pin8)
SPEAKER Z2
SPEAKER Z1
POWER AMP 2
ZON5
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 1 TO 6
FROM POWER
AMPLIFIER 1
121
5
SZ
TRIG
+ -
DC 24V RELAY
CONT
RELAY
24 DC
ZON2AMP 1
V0
M
O
AMP 2ZON1
V
0
M
O
V0
M
O
V0
AMP 4ZON3
V
0
AMP 3
M
O
V0
M
O
M
O
V0
ZON4
M
O
V0
M
O
AMP 5
M
O
V0
V0
SPEAKER Z3
AMP 6
V
0
M
O
V0
M
O
ZON
AMPERES PM1060
PAGING MICROPHONE
N+2 CORE FLEXIBLE CABLE
N= NUMBER OF ZONE
PIN 1-12 : ZONE 1-12
PIN 15 :
PIN 14 :
PIN 13 :
P0
601M
AMPERES ELECTRONICS
CHIME
VOLUME ADJUST
MIC
SER.NBR
0dB
UNBALANCE OUT
REAR VIEW OF PM1120
AUDIO OUT
(TWISTED PAIR SCREEN)
PIN1~12:ZONE1~12
PIN 13 : GND, -VE
PIN 14 : PRIORITY
PIN 15 : +24V DC
PAGE 4
SINGLE UNIT INSTALLATION WITH REMOTE SELECT
The diagram above shows installation of a 3 zone system with remote triggering employing external switches. ( this
is optional ). In this case, zone triggering can be made from remote area but the front panel switches has to be at
OFF position.
Note :
The sample connections shown are using a single
unit of either ZS5121 or ZS5601 in a small scale
installation. ie. small number of zone outputs.
Assumptions made are that :
1. Volume control overriding facilities are done
separately. ( refer example on page 6)
2. Paging or background music is transmitted only
to the zone selected. (Not uninterrupted
paging system )
3. Power amplifier unit 1 is to serve zone 1 and 2
4. Power amplifier untie 2 is to serve zone 3
The illustration below shows a zone selector
connected to the Amperes PM1060 desktop
paging microphone. This shall provide a better
zone selection than the above configuration.
Two way zone selection can be done, either from
the PM1060 or via the front panel switches of the
zone selector, with PM1060 has a priority over
the former.
Example :
With front panel switches 1 and 2 active, and the
user wishes to page zone 3 only, activation of
zone 3 from PM1060 shall override zone 1 and 2.
Upon releasing zone 3 from PM1060, zone 1 and
2 shall then return to its previous state.
ampereselectronics.com
POWER AMP 1
POWER AMP 1
PIN 8-COM
PIN 7-24V
PIN 6-Z6
PIN 5-Z5
PIN 4-Z4
PIN 3-Z3
PIN 2-Z2
PIN 1-Z1
PIN 8-COM
PIN 7-24V
PIN 6-Z6
PIN 5-Z5
PIN 4-Z4
PIN 3-Z3
PIN 2-Z2
PIN 1-Z1
Triggering any zone via the remote port shall override the previously selected zones. No Priority connection
is required.
No connection required for Pin 14 to
zone selector

PAGE 5
MULTIPLE UNIT INSTALLATION ( CASCADING)
ampereselectronics.com
amperes
MX2222
POWER
OFF SELECT
TUNER
CD
CASS
OFF
MASTER
MUSICSOURCE
SIGIN
BASS
MAXMIN
EXTINPUT
MAX MAXMIN
SOURCE
MIN
SIGIN
CHIME MIXER TREBLE
MAXMIN
TONECTRL
CH5 CH6CH4
SIGINSIGIN SIGIN
MAXMIN MAXMIN MIN
CH3CH1 CH2
SIGINSIGIN
MAXMIN MAXMIN MAXMIN MAX
AUX
SIGIN
a sample of system with TD6240 zone decoder and few zone selectors
PD2800
Paging Mic
TD6240 Data
decoder MX2222 Mixer
Power Amplifiers
ZS5121 Zone Selectors
Zone 1 to 12
Zone 13 to 24
Zone 25 to 36
PIN 8-COM
PIN 7-24V
PIN 6-Z6
PIN 5-Z5
PIN 4-Z4
PIN 3-Z3
PIN 2-Z2
PIN 1-Z1
1
New RJ45 Pin configurations
Note that All Call and PR from remote mic shall not
be required
PIN 8-COM
PIN 7-24V
PIN 6-Z6
PIN 5-Z5
PIN 4-Z4
PIN 3-Z3
PIN 2-Z2
PIN 1-Z1
PIN 8-COM
PIN 7-24V
PIN 6-Z12
PIN 5-Z11
PIN 4-Z10
PIN 3-Z9
PIN 2-Z8
PIN 1-Z7
PIN 8-COM
PIN 7-24V
PIN 6-Z6
PIN 5-Z5
PIN 4-Z4
PIN 3-Z3
PIN 2-Z2
PIN 1-Z1
PIN 8-COM
PIN 7-24V
PIN 6-Z12
PIN 5-Z11
PIN 4-Z10
PIN 3-Z9
PIN 2-Z8
PIN 1-Z7
PIN 8-COM
PIN 7-24V
PIN 6-Z6
PIN 5-Z5
PIN 4-Z4
PIN 3-Z3
PIN 2-Z2
PIN 1-Z1
PIN 8-COM
PIN 7-24V
PIN 6-Z12
PIN 5-Z11
PIN 4-Z10
PIN 3-Z9
PIN 2-Z8
PIN 1-Z7
to TD6240 Unit 1
Trigger Port 1
to TD6240 Unit 1
Trigger Port 2
to TD6240 Unit 1
Trigger Port 3
to TD6240 Unit 1
Trigger Port 4
to TD6240 Unit 2
Trigger Port 1
to TD6240 Unit 2
Trigger Port 2
For Zone 1 to 12
For Zone 13 to 24
for Zone 25 to 36
ALL CALL to all units can be triggered from paging mic.
Pressing ALL CALL button from zone selector front panel shall only trigger
all zones of the particular unit only.
Use EP1200 to make ALL CALL to all ZS installed - refer to page 6
This manual suits for next models
1
Table of contents
Other Amperes Recording Equipment manuals