Amperes ZS5062 User manual

INSTRUCTION MANUAL
ZS5062 / 5122
6 / 12 Ch Speaker Zone Selector
Ver 2 / 2023
Thank you for choosing another quality product om Amperes Electronics.
ZS5062 / 5122 has been upgraded with higher power load for each zone of up to 1000W 100V line, due to larger requirement
of modern installations.
These series has fail safe feature that would ensure the speaker line will be connected to the amplifier output continuously if
the unit fails. This ensure the overall EVAC or paging would not be interrupted for any malfunction in the zone selector.
Although it is not difficult to install the unit, a brief reading of the manual is truly recommended to avoid any misconnection as
well as to explore the potential usage of the product to its maximum capability.
SPEAKER ZONE SELECTOR
21 3 54
SPEAKER ZONE SELECT
6 7 8 9 10 1211
ZS 5122 amperes
OVERRIDE
ALL CALL
SPEAKER ZONE SELECTOR
OVERRIDE
21 3 54
SPEAKER ZONE SELECT
6
ALL CALL
ZS 5062 amperes

1. BGM ZONE OVERRIDING INDICATOR
The LED shall lit if remote paging microphone is active and is overriding the local BGM zone selection. This
is active if Amperes PM 1060 paging is used or any other paging microphone console with Priority output signal.
3. FRONT PANEL ZONE SWITCHES - ZONE 1 TO 6
Switching for zone 1 to 6.
Parts Identifications
SPEAKER ZONE SELECTOR
21 3 54
SPEAKER ZONE SELECT
6 7 8 9 10 1211
ZS 5122 amperes
OVERRIDE
ALL CALL
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 1 TO 6
ZONE SELECTOR
ZS 5122
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 7 TO 12
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
ZREMOTE SELECTREMOTE SELECT
A B
RS485
100V
AMP 4AMP 1
100V
ZON2
100V
COM
100V
100V
COM
COM
ZON1 AMP 2
COM
100V
COM
COM
AMP 3
100V
ZON3
COM
ZON6
COM
COM
ZON4
100V
COM
100V
AMP 5
100V
100V
AMP 6
COM
ZON5
COM
100V
COM
ZON12
AMP 7
100V
100V
AMP10
ZON8
100V
100V
ZON7
COM
COM
COM
AMP 8
100V
100V
100V
COM
COM
COM
AMP 9 ZON9
100V
100V
COM
COM
COM
ZON10 AMP11
100V
100V
100V
COM
COM
ZON11 AMP12
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
1-Z7
2-Z8
3-Z9
4-Z10
5-Z11
6-Z12
7-24V
8-COM
UNIT ADD
ON
8
4
21
ZONE 1 TO 6 ZONE 7 TO 12
Quality Product From
AMPERES ELECTRONICS
2
10
9
3
6
1
511 12
6. EMERGENCY OVERRIDE TERMINAL
8
2. ALL CALL SWITCH
All zones will be activated by pressing this switch, regardless of any inactive zone.
5. DC SUPPLY INPUT PORT
4. FRONT PANEL ZONE SWITCHES - ZONE 7 TO 12
Switching for zone 7 to 12 for ZS5122 only.
4
Front View
Rear View
24V DC supply is required to operate this unit. Ensure polarity is correctly terminated to the port. It is recom-
mended that supply with 1A rating of regulated source is used. Amperes PS9400 is recommended as a DC supply
source to your installation.
PAGE 2 ZS5062 / ZS5122 6 / 12 CHANNEL SPEAKER ZONE SELECTOR
External switch ( eg. fr emergency paging mic with dry contact ) can be connected here, which shall trigger the built in
relay when pressed. This shall then provide a dry contact in which would enable the installer to apply several functions
such as providing 24V DC output for volume controller overriding purpose, trigger external device or link to BAS
system, etc.
7

8. UNIT ADDRESS DIP SWITCH
9. REMOTE SELECT PORT - Z1 TO 6
11. REMOTE SELECT PORT - Z7 TO 12
Similar function as Part 9 but only available for ZS5122.
Parts Identifications
PAGE 3
ZS5062 / ZS5122 6 / 12 CHANNEL SPEAKER ZONE SELECTOR
When it is required to be linked to Amperes PMX II software for monitoring purpose, the unit / units are required to be
addressed. Binary code addressing is used in setting the unit’s ID. ( Future application )
10. AMPLIFIER - ZONE OUTPUT CONNECTORS (ZONE 1 TO 6)
12. AMPLIFIER - ZONE OUTPUT CONNECTORS (ZONE 7 TO 12)
7. RS485 DATA PORT
RS485 data port is used to interface with other Amperes products, to enable simpler cabling or interconnection works.
Alternatively, it can be linked to PC for firmware upgrade. A USB-RS485 converter shall be required for this purpose.
Please refer to section ‘ Firmware Upgrading’ to perform the Firmware update process.
When link multiple units of ZS, connect all RS485 ports together, to enable PD paging mic to control the zonings. ( override
local zone selections via front panel switches ).
This is to connect to remote paging mic ( PM Series ) or Data Decoder ( TD Series ) for remote zone triggering. Upon trigger-
ing the zone via this port, it shall override the locally selected zones. External triggering switches or other made of paging
microphones can utilise this facility provided that -ve triggering method is used.
Outputs from amplifiers are connected to these terminals and speaker zoning is configured to the respective unit of amplifier.
The user has the flexibility to configure the zoning system as each zone comes with single amplifier output connection.
Please observe polarity when terminating the amplifier / speaker zones to ensure that each zone is not overloaded. ( Less
than 1000W rms per channel ).
Similar function as Part 10 but only available for ZS5122.

REMOTE ZONE SWITCHES
Z2
Z6
Z1
24 DC
ZONE 1
FROM POWER
AMPLIFIER 1
-VE (Pin8)
POWER AMP 2
24 DC
Zone 1 to 6
Cat5 Cable
Zone 7 to 12
Note :
The sample connections shown are using a single
unit of either ZS5122 or ZS5062 in a small scale
installation. ie. small number of zone outputs.
Assumptions made are that :
1. Volume control overriding facilities are done
separately. ( refer example on page 6)
2. Paging or background music is transmitted only
to the zone selected. (Not uninterrupted
paging system )
3. Power amplifier unit 1 is to serve zone 1 and 2
POWER AMP 1
POWER AMP 1
Triggering any zone via the remote port shall override the previously selected zones. No Priority connection is
required.
Single Unit Installation With Remote Select
PAGE 4 ZS5062 / ZS5122 6 / 12 CHANNEL SPEAKER ZONE SELECTOR
AMPLIFIER INPUTS - ZONE OUTPUTS FOR
ZONE SELECTOR
ZS 5122
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
ZREMOTE SELECT
A B
RS485
100V
AMP 4AMP 1
100V
ZON2
100V
COM
100V
100V
COM
COM
ZON1 AMP 2
COM
100V
COM
COM
AMP 3
100V
ZON3
COM
ZON4
100V
COM
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
UNIT ADD
ON
8
4
21
ZONE 1 TO 6
Quality Product From
AMPERES ELECTRONICS
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 1 TO 6
ZONE SELECTOR
ZS 5122
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
ZREMOTE SELECTREMOTE SELECT
A B
RS485
100V
AMP 4AMP 1
100V
ZON2
100V
COM
100V
100V
COM
COM
ZON1 AMP 2
COM
100V
COM
COM
AMP 3
100V
ZON3
COM
ZON6
COM
COM
ZON4
100V
COM
100V
AMP 5
100V
100V
AMP 6
COM
ZON5
COM
100V
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
1-Z7
2-Z8
3-Z9
4-Z10
5-Z11
6-Z12
7-24V
8-COM
UNIT ADD
ON
8
4
21
ZONE 1 TO 6 ZONE 7 TO 12
Quality Product From
AMPERES ELECTRONICS
ZONE 2
The diagram above shows an installation of a 2 zone system with remote triggering, employing external switches ( optional ).
In this case, zone triggering can be made from remote location.
The diagram here show a zone selector connected to
Amperes PM1120 desktop paging microphone.
Two way zone selection can be done, either from the
PM1120 or using the front panel switches of the zone selec-
tor. When PM1120 zone is selected, it shall bypass the
selected front panel zone switches.
Example :
With front panel zone switches 1 and 2 active and the use
wishes to page zone 3 only, activation of zone 3 from
paging mic will override zone 1 and 2 ( muted ).
Upon releasing zone 3 from PM1120, the previouse state of
Zone 1 and 2 shall resume.
PM1060 / 1120
Analogue
Paging Mic

amperes
MX2222
POW ER
OFF SEL E CT
TUN ER
CD
CASS
OFF
MA S TE R
MUS I C S O U R C E
SIG IN
BAS S
MAXMIN
EXT IN P U T
MAX MAXMIN
SOU R C E
MIN
SIG IN
CHIM E MIX E R TREBLE
MAXMIN
TON E C TR L
CH5 CH6CH4
SIG INSI G IN SIG IN
MAXMIN MAXMIN MIN
CH3CH1 CH2
SIG INSIG IN
MAXMIN MAXMIN MAXMIN MAX
AUX
SIG IN
a sample of system with TD6240 zone decoder and few zone selectors
PD2800
Paging Mic
TD6240 Data
decoder MX2222 Mixer
Power Amplifiers
ZS5122 Zone Selectors
Zone 1 to 12
Zone 13 to 24
Zone 25 to 36
P IN 8 -C O M
P IN 7 -2 4V
P IN 6 -Z 6
P IN 5 -Z 5
P IN 4 -Z 4
P IN 3 -Z 3
P IN 2 -Z 2
P IN 1 -Z 1
1
RJ45 Pin configurations
Note that All Call and PR from remote mic shall not be required
Switching signal
audio
Multiple Units Installation ( Cascading )
PAGE 5ZS5062 / ZS5122 6 / 12 CHANNEL SPEAKER ZONE SELECTOR
SPEAKER ZONE SELECTOR
21 3 54
SPEAKER ZONE SELECT
6 7 8 9 10 1211
ZS 5122 amperes
OVERRIDE
ALL CALL
SPEAKER ZONE SELECTOR
21 3 54
SPEAKER ZONE SELECT
6 7 8 9 10 1211
ZS 5122 amperes
OVERRIDE
ALL CALL
SPEAKER ZONE SELECTOR
21 3 54
SPEAKER ZONE SELECT
6 7 8 9 10 1211
ZS 5122 amperes
OVERRIDE
ALL CALL
to TD6240 Unit
1 Trigger Port 1
to TD6240 Unit
1 Trigger Port 2
to TD6240 Unit
1 Trigger Port 3
to TD6240 Unit
1 Trigger Port 4
to TD6240 Unit 2
Trigger Port 1
to TD6240 Unit 2
Trigger Port 2
For Zone 1 to 12
For Zone 13 to 24
For Zone 25 to 36
ALL CALL to all units can be triggered from paging mic.
Pressing ALL CALL button from zone selector front panel shall only trigger all
zones of the particular unit only. And the connection Z PR must link.
Use EP1200A to make ALL CALL to all ZS installed - refer to page 6.
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 7 TO 12
REMOTE SELECT
COM
ZON12
AMP 7
100V
100V
AMP10
ZON8
100V
100V
ZON7
COM
COM
COM
AMP 8
100V
100V
100V
COM
COM
COM
AMP 9 ZON9
100V
100V
COM
COM
COM
ZON10 AMP11
100V
100V
100V
COM
COM
ZON11 AMP12
ZONE 7 TO 12
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 7 TO 12
REMOTE SELECT
COM
ZON12
AMP 7
100V
100V
AMP10
ZON8
100V
100V
ZON7
COM
COM
COM
AMP 8
100V
100V
100V
COM
COM
COM
AMP 9 ZON9
100V
100V
COM
COM
COM
ZON10 AMP11
100V
100V
100V
COM
COM
ZON11 AMP12
ZONE 7 TO 12
AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 7 TO 12
REMOTE SELECT
COM
ZON12
AMP 7
100V
100V
AMP10
ZON8
100V
100V
ZON7
COM
COM
COM
AMP 8
100V
100V
100V
COM
COM
COM
AMP 9 ZON9
100V
100V
COM
COM
COM
ZON10 AMP11
100V
100V
100V
COM
COM
ZON11 AMP12
ZONE 7 TO 12
ZONE SELECTOR
ZS 5122
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
Z
A B
RS485
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
UNIT ADD
ON
8
4
21
Quality Product From
AMPERES ELECTRONICS
REMOTE SELECT
ZONE 1 TO 6
ZONE SELECTOR
ZS 5122
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
Z
A B
RS485
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
UNIT ADD
ON
8
4
21
Quality Product From
AMPERES ELECTRONICS
REMOTE SELECT
ZONE 1 TO 6
ZONE SELECTOR
ZS 5122
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
Z
A B
RS485
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
UNIT ADD
ON
8
4
21
Quality Product From
AMPERES ELECTRONICS
REMOTE SELECT
ZONE 1 TO 6

Connecting Emergency Overriding Port
Triggering from EP1200
Emergency Paging Mic
to volume controllers
overriding
Link these ports
+
DC 24V
CON
RLY
TRIG
RLY
PR
ZS
PAGE 6 ZS5062 / ZS5122 6 / 12 CHANNEL SPEAKER ZONE SELECTOR
ZS 5122
ZONE SELECTOR
ZS 5122
DC 24V
+ - CONT
RELAYRELAY
TRIG
REMOTE SELECT
RS485
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
UNIT ADD
ON
8
421
ZONE 1 TO 6
Quality Product From
AMPERES ELECTRONICS
ZONE SELECTOR
ZS 5122
DC 24V
+ - CONT
RELAYRELAY
TRIG PR
ZREMOTE SELECT
A B
RS485
1-Z1
2-Z2
3-Z3
4-Z4
5-Z5
6-Z6
7-24V
8-COM
UNIT ADD
ON
8
421
ZONE 1 TO 6
Quality Product From
AMPERES ELECTRONICS
+VE
-VE
+VE
24V DC
-VE
24V DC
(PS9400)
To volume controller overriding relay or other emergency indicator or
emergency interface:
Relay rating : 2A
Emergency paging microphone switch or other
emergency trigger button
More than often, volume controllers are installed at areas that require sound level to be attenuated, eg. Conference room,
function hall, etc.
Ovrriding is required when an emergency switch is pressed, normally via fireman paging panel with a dry contact. With the
Connection shown, whenever the switch is pressed, it will trigger the internal relay which shall then provide a dry contact. It
can be used to trigger overriding relay at volume controller or other external device such as emergency light indicator.
Please ensure the loading of the relay is not exceeded. Polarity must also be observed when connecting this port.
All Call paging can be performed from
Emergency Paging Mic ( EP1200 ),
which when Relay Trigger port is
energised, it shall provide a voltage free
relay contact. Connect 24V DC power
supply from PSU to trigger external
volume controllers for overriding
purpose.
When multiple ZS are used, link the
Relay Trig ports together, thus any
triggering from EP1200 shall perform All
Call paging to all zones at all the zone
selectors
Note :
Pressing All Call at individual zone
selector shall only trigger all zones at the
respective unit, without triggering the
relay output, thus shall not override the
volume controller.
PR
Z
Link RS485 for multiple ZS
connections
- VE
+VE

The block diagram shown is for the installer to
have a better understanding on how the unit
works when interfacing it with other brands of
PA equipment.
It is however not recommended that the internal
circuitry of the unit be modified without prior
consultation with the manufacturer .
Operating voltage
Power consumption (idle)
Number of Zones
Amplifier inputs
Zone selection
Remote triggering
Indicators
Dimensions (W x H x D)
Weight
ZS5062 ZS5122
24V DC adaptor
3.29W
Max load / channel 1000W at 100V line
12
Front panel switch and remote
16
-ve triggered (common ground)
Switching mode Individual, All Call
Local zone selection bypassed when remote
trigger is activated
482 x 44 x 180 mm
1.95 kg
6.25W
Cascade limitation
6 12
6
Individual zone switch, Priority
2.1 kg
Current consumption (idle) 0.14A 0.26A
REMOTE SELECT Z12
REMOTE SELECT Z1
+VE 24V OUT
-VE
ZS PR
Block Diagram
Technical Specifications
PAGE 7ZS5062 / ZS5122 6 / 12 CHANNEL SPEAKER ZONE SELECTOR
RS485 DATA
Power consumption (All Call)
Current consumption (All Call)
0.72W 0.96W
0.03A 0.04A
Data Communication RS485 19.2 kbps baud rate

Warranty Conditions
Disclaimer
AMPERES ELECTRONICS SDN BHD
MADE IN MALAYSIA
Published : MAY 2023
ISO 9001: 2015
Design & Manufacture of Public Address Equipment and Systems
Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes Electronics authorized
service centres may be asked by the purchaser or send directly to Amperes Electronics Sdn Bhd at 70 Jalan Industri PBP3,
Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor. This warranty is not valid if repairs are performed by
unauthorized personnel or service centres.
This warranty covers only repairs and replacement of defective parts. Cost and risk of transportation as well as removal and
installation of the product from the main system are for the account of the purchaser. This warranty shall not extend to the
replacement of the unit.
This warranty does not cover damages caused by misuse, negligence in application as well as using the product with power
supply voltage other than shown on the product, or any other power supply source / adapter not recommended by the manu-
facturer.
This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not directly related to
the unit.
This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use of the unit, more-
over the warranty does not cover any damages which may cause to the people and things during the use of the product.
This warranty certificate is valid only for the described product, and is not valid if modifications are made on this certificate or
identification labels applied to the unit or any other modifications to the physical unit other than its intended usage.
This warranty covers all the material and manufacturing defects and is valid for a period of 36 months from the date of
purchase or for a specified period in countries where this is stated by a national law. In this case, the extension is valid only in
the country where the product is purchased.
Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if the design changes
or improvements are made.
The purchaser is deemed to agree to the above warranty conditions once the product packaging is unpacked., Otherwise the
product shall be returned to the seller in proper original condition.
Information contained in this manual is subjected to change without prior notice and does not represent a commitment on the
part of the vendor. Amperes Electronics Sdn Bhd shall not be liable for any loss or damages whatsoever arising from the use
of information or any error contained in this manual.
It is recommended that all services and repairs of this product to be carried out by Amperes Electronics or its authorized
service agents.
Amperes products must only be used for the purpose they were intended by the manufacturer and in conjunction with this
operation manual.
Amperes Electronics Sdn Bhd cannot accept any liability whatsoever for any loss or damages caused by service, mainte-
nance or repair by unauthorized personnel, or by use other than that intended by the manufacturer.
This manual suits for next models