manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. AMX
  6. •
  7. Control Unit
  8. •
  9. AMX DG DVI MTP User manual

AMX DG DVI MTP User manual

This manual suits for next models

1

Other AMX Control Unit manuals

AMX DCE-1 User manual

AMX

AMX DCE-1 User manual

AMX MAX-AVM User manual

AMX

AMX MAX-AVM User manual

AMX AXB-PCCOM User manual

AMX

AMX AXB-PCCOM User manual

AMX AXU-MSP8 User manual

AMX

AMX AXU-MSP8 User manual

AMX HPX-N102-USB-PC User manual

AMX

AMX HPX-N102-USB-PC User manual

AMX RDM-DC Quick start guide

AMX

AMX RDM-DC Quick start guide

AMX CTC-1402 User manual

AMX

AMX CTC-1402 User manual

AMX RDM-FDB Quick start guide

AMX

AMX RDM-FDB Quick start guide

AMX HPX-AV102-RGB+A-R User manual

AMX

AMX HPX-AV102-RGB+A-R User manual

AMX RMX 16 User manual

AMX

AMX RMX 16 User manual

AMX CAT-5 RGBHV RX User manual

AMX

AMX CAT-5 RGBHV RX User manual

AMX NetLinx NXM-MHS User manual

AMX

AMX NetLinx NXM-MHS User manual

AMX HPX-AV100-RGB+A User manual

AMX

AMX HPX-AV100-RGB+A User manual

AMX RDM-HFDB Quick start guide

AMX

AMX RDM-HFDB Quick start guide

AMX AXC-VOL Guide

AMX

AMX AXC-VOL Guide

AMX FG1010-720 User manual

AMX

AMX FG1010-720 User manual

AMX RDA-CKM Quick start guide

AMX

AMX RDA-CKM Quick start guide

AMX HPX-1600 User manual

AMX

AMX HPX-1600 User manual

AMX RDM-DPSM Guide

AMX

AMX RDM-DPSM Guide

AMX RDA-CKM Assembly instructions

AMX

AMX RDA-CKM Assembly instructions

AMX HPX-U100-BTN User manual

AMX

AMX HPX-U100-BTN User manual

AMX PLB-CF2 User manual

AMX

AMX PLB-CF2 User manual

AMX NXS-NMS User manual

AMX

AMX NXS-NMS User manual

AMX Encore User manual

AMX

AMX Encore User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Quick Start Guide
AutoPatch DG DVI MTP Fiber Modules
Overview
DG (Digital Generation) DVI MTP®Fiber Transmitter (TX) and Receiver (RX) Modules
work together (FIG. 2) or in conjunction with MTP Fiber boards on an AMX AutoPatch
Distribution Matrix. This guide contains complete information for standalone use.
For use with a distribution matrix, see the distribution matrix’s instruction manual on
the AMX AutoPatch Software & Documentation CD or visit www.amx.com.
A table containing EDID resolutions is included on the reverse.
Product Specifications
Mounting Options
• Desktop – attach the rubber feet (included) on the bottom of the module.
• Rack Trays & Mounting Brackets – contact your AMX representative for details.
Installation
Typical System Setup
The TX receives DVI-D signals from 3 source devices and sends them over one fiber
cable. The RX accepts the signals from the fiber cable, converts the signals back to
DVI-D, and sends each signal to its corresponding destination device.
Attaching Connectors
Note: The DVI connector numbers on the TX and RX correspond to the Video Signal
indicators on the front of the TX.
To attach connectors:
1. Check EDID switch on front of TX to be sure that it remains set to the right (WP).
2. For each source device, insert the DVI connector into the DVI jack on the rear of
the TX (FIG. 3). For DVI-I pinout, see FIG. 5.
3. For each destination device, insert the DVI connector into the DVI jack on the
rear of the RX.
Caution: Do not severely bend or kink the fiber cable. These
actions can cause irreversible damage to the cable.
4. Insert the MTP/MPO plug on oneend of the fiber cable into the Fiber (MTP/MPO)
jack on the front of the TX (FIG. 4).
5. Insert the other end of the fiber cable into the Fiber jack on the front of the RX.
6. For each destination device, insert its DVI plug into a DVI jack on rear of the RX.
7. Insert the power plugs into the power jacks on the TX and RX (FIG. 4).
8. Plug the power transformers into the power sources.
DVI-I TX & RX Module Connector Pinouts
* The +5 V on pin 14 on the TX Module will supply a maximum of 55 mA.
TX LED Indicators
Video Signal Indicators
Numbering corresponds to the numbering for DVI connectors on the rear of the TX.
• Green – DVI signal path has a valid signal
• Red – DVI signal path has lost its signal
Fault Indicator (Optical)
• OFF – Optical converter is functioning normally
• Red – Optical converter has a fault condition
Troubleshooting
If an indicator on the TX is red, check its corresponding connector and the
corresponding connector on the source device and then cycle power on the TX.
MTP®is a registered trademark of US Conec, Ltd.
FIG. 1 Transmitter (TX) FG1010-60 Receiver (RX) FG1010-63
Product Specifications
Approvals CE
Power Consumption (max.) +12 V - +24 V DC, 14 W
Power Connector 2.1 mm DC power jack
Humidity 0 to 90% non-condensing
Operational Temperature 32° - 110° F (0° - 43° C)
Dimensions 5.22 in. (13.26 cm) depth
5.82 in. (14.78 cm) width
1.42 in. (3.61 cm) height without feet
Weight Approximately 1.5 lbs (0.68 kg)
CompatibleAMXAutoPatch
Fiber Equipment DVI - MTP Fiber Modules
RGBHV - MTP Fiber Modules
Other AMX AutoPatch MTP Fiber products
Resolution Support Up to 1920x1200 @ 60 Hz refresh rate w/ reduced blanking
Up to 1600x1200 @ 60 Hz refresh rate
DDC/EDID Support EDID provided by DVI TX Module (EDID resolution list on back)
Pixel Bandwidth (bit rate) 1.65 Gbps
Specification Compliant DVI 1.0, DVI-D (single link DVI)
HDCP Support No
Input Cable Equalization Up to 50 ft. (15.24 m)
Fiber Cable Types 12 Fiber Multimode MTP, 50/125 µm or 62.5/125 µm
Fiber Cable Length Up to 3000 ft. (914.4 m) cable requires low loss, controlled
skew fiber cable, such as, Alcoa 50/125 µm Laser-Link 550
Fiber Cable Termination Female MTP
Fiber Connector on Module Male MTP (guide pins define it as a male)
DVI Connectors DVI-I (DVI-D is supported signal type)
FIG. 2 Typical system setup
Front
Rear
DVD
Fiber up to 3000 ft. (914 m)
FG1010-60
FG1010-63
TX
RX
Source devices Destination devices
FIG. 3 Attach DVI connectors
FIG. 4 Attach fiber cable & power cable
FIG. 5 TX & RX DVI-I input & output pinouts
DVI connectors
Power jack Power indicator
Video Signal indicators Fault indicator
MTP connector
EDID switch remains
so source & destination
can share information.
set to WP (Write-Protect),
For full warranty information, refer to www.amx.com.
6/07
©2007 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
AMX reserves the right to alter specifications without notice at any time.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
93-10-846 REV: A0
EDID Supported Resolutions
EDID Supported Resolutions
Resolution Refresh Rate
1920x1200 60 Hz reduced sync blanking only
1920x1080 60 Hz reduced sync blanking only
1680x1050 60 Hz
1600x1200 60 Hz
1280x1024 60 Hz - 75 Hz
1280x960 60 Hz - 75 Hz
1280x768 60 Hz - 85 Hz
1280x720 60 Hz - 85 Hz
1152x864 60 Hz - 85 Hz
1024x768 60 Hz - 85 Hz
800x600 60 Hz - 85 Hz