manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. AMX
  6. •
  7. Control Unit
  8. •
  9. AMX DG DVI MTP User manual

AMX DG DVI MTP User manual

This manual suits for next models

1

Other AMX Control Unit manuals

AMX RDM-HDC Manual

AMX

AMX RDM-HDC Manual

AMX 8450-03 User manual

AMX

AMX 8450-03 User manual

AMX RDM-DPSM Guide

AMX

AMX RDM-DPSM Guide

AMX RDM-HSW Quick start guide

AMX

AMX RDM-HSW Quick start guide

AMX RDM-ZC Quick start guide

AMX

AMX RDM-ZC Quick start guide

AMX FG1010-720 User manual

AMX

AMX FG1010-720 User manual

AMX NXS-NMS User manual

AMX

AMX NXS-NMS User manual

AMX RDA-CKM Quick start guide

AMX

AMX RDA-CKM Quick start guide

AMX RMX 16 User manual

AMX

AMX RMX 16 User manual

AMX CTC-1402 User manual

AMX

AMX CTC-1402 User manual

AMX RDM-HFDB Quick start guide

AMX

AMX RDM-HFDB Quick start guide

AMX MAX-AOM User manual

AMX

AMX MAX-AOM User manual

AMX HPX-N101-ETH-R User manual

AMX

AMX HPX-N101-ETH-R User manual

AMX HPX-1600 User manual

AMX

AMX HPX-1600 User manual

AMX HPX-N102-USB-PC User manual

AMX

AMX HPX-N102-USB-PC User manual

AMX Encore User manual

AMX

AMX Encore User manual

AMX MAX-AVM User manual

AMX

AMX MAX-AVM User manual

AMX AXB-DTMF Plus User manual

AMX

AMX AXB-DTMF Plus User manual

AMX SD-2 Quick start guide

AMX

AMX SD-2 Quick start guide

AMX HPX-AV100-RGB+A User manual

AMX

AMX HPX-AV100-RGB+A User manual

AMX HPX-U100-BTN User manual

AMX

AMX HPX-U100-BTN User manual

AMX NetLinx NXM-MHS User manual

AMX

AMX NetLinx NXM-MHS User manual

AMX PLB-CF2 User manual

AMX

AMX PLB-CF2 User manual

AMX AXB-PCCOM User manual

AMX

AMX AXB-PCCOM User manual

Popular Control Unit manuals by other brands

Festo Compact Performance CP-FB6-E Brief description

Festo

Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

Elo TouchSystems

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation MPC3034A user manual

JS Automation

JS Automation MPC3034A user manual

JAUDT SW GII 6406 Series Translation of the original operating instructions

JAUDT

JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum Air Module System manual

Spektrum

Spektrum Air Module System manual

BOC Edwards Q Series instruction manual

BOC Edwards

BOC Edwards Q Series instruction manual

KHADAS BT Magic quick start

KHADAS

KHADAS BT Magic quick start

Etherma eNEXHO-IL Assembly and operating instructions

Etherma

Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations Attenuverter Assembly guide

PMFoundations

PMFoundations Attenuverter Assembly guide

GEA VARIVENT Operating	 instruction

GEA

GEA VARIVENT Operating instruction

Walther Systemtechnik VMS-05 Assembly instructions

Walther Systemtechnik

Walther Systemtechnik VMS-05 Assembly instructions

Altronix LINQ8PD Installation and programming manual

Altronix

Altronix LINQ8PD Installation and programming manual

Eaton Powerware Series user guide

Eaton

Eaton Powerware Series user guide

WAGO 750-407/040-000 manual

WAGO

WAGO 750-407/040-000 manual

Sony CCU-590 Operation manual

Sony

Sony CCU-590 Operation manual

Graco 25D614 instructions

Graco

Graco 25D614 instructions

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Task Force Tips

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Shini SPV-U Series manual

Shini

Shini SPV-U Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Quick Start Guide
AutoPatch DG DVI MTP Fiber Modules
Overview
DG (Digital Generation) DVI MTP®Fiber Transmitter (TX) and Receiver (RX) Modules
work together (FIG. 2) or in conjunction with MTP Fiber boards on an AMX AutoPatch
Distribution Matrix. This guide contains complete information for standalone use.
For use with a distribution matrix, see the distribution matrix’s instruction manual on
the AMX AutoPatch Software & Documentation CD or visit www.amx.com.
A table containing EDID resolutions is included on the reverse.
Product Specifications
Mounting Options
• Desktop – attach the rubber feet (included) on the bottom of the module.
• Rack Trays & Mounting Brackets – contact your AMX representative for details.
Installation
Typical System Setup
The TX receives DVI-D signals from 3 source devices and sends them over one fiber
cable. The RX accepts the signals from the fiber cable, converts the signals back to
DVI-D, and sends each signal to its corresponding destination device.
Attaching Connectors
Note: The DVI connector numbers on the TX and RX correspond to the Video Signal
indicators on the front of the TX.
To attach connectors:
1. Check EDID switch on front of TX to be sure that it remains set to the right (WP).
2. For each source device, insert the DVI connector into the DVI jack on the rear of
the TX (FIG. 3). For DVI-I pinout, see FIG. 5.
3. For each destination device, insert the DVI connector into the DVI jack on the
rear of the RX.
Caution: Do not severely bend or kink the fiber cable. These
actions can cause irreversible damage to the cable.
4. Insert the MTP/MPO plug on oneend of the fiber cable into the Fiber (MTP/MPO)
jack on the front of the TX (FIG. 4).
5. Insert the other end of the fiber cable into the Fiber jack on the front of the RX.
6. For each destination device, insert its DVI plug into a DVI jack on rear of the RX.
7. Insert the power plugs into the power jacks on the TX and RX (FIG. 4).
8. Plug the power transformers into the power sources.
DVI-I TX & RX Module Connector Pinouts
* The +5 V on pin 14 on the TX Module will supply a maximum of 55 mA.
TX LED Indicators
Video Signal Indicators
Numbering corresponds to the numbering for DVI connectors on the rear of the TX.
• Green – DVI signal path has a valid signal
• Red – DVI signal path has lost its signal
Fault Indicator (Optical)
• OFF – Optical converter is functioning normally
• Red – Optical converter has a fault condition
Troubleshooting
If an indicator on the TX is red, check its corresponding connector and the
corresponding connector on the source device and then cycle power on the TX.
MTP®is a registered trademark of US Conec, Ltd.
FIG. 1 Transmitter (TX) FG1010-60 Receiver (RX) FG1010-63
Product Specifications
Approvals CE
Power Consumption (max.) +12 V - +24 V DC, 14 W
Power Connector 2.1 mm DC power jack
Humidity 0 to 90% non-condensing
Operational Temperature 32° - 110° F (0° - 43° C)
Dimensions 5.22 in. (13.26 cm) depth
5.82 in. (14.78 cm) width
1.42 in. (3.61 cm) height without feet
Weight Approximately 1.5 lbs (0.68 kg)
CompatibleAMXAutoPatch
Fiber Equipment DVI - MTP Fiber Modules
RGBHV - MTP Fiber Modules
Other AMX AutoPatch MTP Fiber products
Resolution Support Up to 1920x1200 @ 60 Hz refresh rate w/ reduced blanking
Up to 1600x1200 @ 60 Hz refresh rate
DDC/EDID Support EDID provided by DVI TX Module (EDID resolution list on back)
Pixel Bandwidth (bit rate) 1.65 Gbps
Specification Compliant DVI 1.0, DVI-D (single link DVI)
HDCP Support No
Input Cable Equalization Up to 50 ft. (15.24 m)
Fiber Cable Types 12 Fiber Multimode MTP, 50/125 µm or 62.5/125 µm
Fiber Cable Length Up to 3000 ft. (914.4 m) cable requires low loss, controlled
skew fiber cable, such as, Alcoa 50/125 µm Laser-Link 550
Fiber Cable Termination Female MTP
Fiber Connector on Module Male MTP (guide pins define it as a male)
DVI Connectors DVI-I (DVI-D is supported signal type)
FIG. 2 Typical system setup
Front
Rear
DVD
Fiber up to 3000 ft. (914 m)
FG1010-60
FG1010-63
TX
RX
Source devices Destination devices
FIG. 3 Attach DVI connectors
FIG. 4 Attach fiber cable & power cable
FIG. 5 TX & RX DVI-I input & output pinouts
DVI connectors
Power jack Power indicator
Video Signal indicators Fault indicator
MTP connector
EDID switch remains
so source & destination
can share information.
set to WP (Write-Protect),
For full warranty information, refer to www.amx.com.
6/07
©2007 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
AMX reserves the right to alter specifications without notice at any time.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
93-10-846 REV: A0
EDID Supported Resolutions
EDID Supported Resolutions
Resolution Refresh Rate
1920x1200 60 Hz reduced sync blanking only
1920x1080 60 Hz reduced sync blanking only
1680x1050 60 Hz
1600x1200 60 Hz
1280x1024 60 Hz - 75 Hz
1280x960 60 Hz - 75 Hz
1280x768 60 Hz - 85 Hz
1280x720 60 Hz - 85 Hz
1152x864 60 Hz - 85 Hz
1024x768 60 Hz - 85 Hz
800x600 60 Hz - 85 Hz
640x480 60 Hz - 85 Hz