manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. AMX
  6. •
  7. Controllers
  8. •
  9. AMX Control Card RDC-PDC Assembly instructions

AMX Control Card RDC-PDC Assembly instructions

This manual suits for next models

2

Other AMX Controllers manuals

AMX AXC-232 User manual

AMX

AMX AXC-232 User manual

AMX NXI User manual

AMX

AMX NXI User manual

AMX NX-2200 User manual

AMX

AMX NX-2200 User manual

AMX AXB-CAM User manual

AMX

AMX AXB-CAM User manual

AMX NetLinx NXC-COM2 User manual

AMX

AMX NetLinx NXC-COM2 User manual

AMX AXR-MSE Guide

AMX

AMX AXR-MSE Guide

AMX DAS-D-0404 User manual

AMX

AMX DAS-D-0404 User manual

AMX AXC-SLD User manual

AMX

AMX AXC-SLD User manual

AMX AXB-VOL3 User manual

AMX

AMX AXB-VOL3 User manual

AMX AXB-TM5 User manual

AMX

AMX AXB-TM5 User manual

AMX NX-1200 Quick user guide

AMX

AMX NX-1200 Quick user guide

AMX NetLinx Integrated Controller NI-4100 User manual

AMX

AMX NetLinx Integrated Controller NI-4100 User manual

AMX NXC-COM2 Guide

AMX

AMX NXC-COM2 Guide

AMX AXB-F117 Stealth 1 User manual

AMX

AMX AXB-F117 Stealth 1 User manual

AMX AXC-REL8 Guide

AMX

AMX AXC-REL8 Guide

AMX SC-N8012 User manual

AMX

AMX SC-N8012 User manual

AMX NX-1200 Quick user guide

AMX

AMX NX-1200 Quick user guide

AMX NXP-PLV User manual

AMX

AMX NXP-PLV User manual

AMX NetLinx Integrated Controllers NI-700/900 Operating and maintenance manual

AMX

AMX NetLinx Integrated Controllers NI-700/900 Operating and maintenance manual

AMX AXB-EM232 User manual

AMX

AMX AXB-EM232 User manual

AMX Control Card RDC-DC Assembly instructions

AMX

AMX Control Card RDC-DC Assembly instructions

AMX NetLinx Integrated Controller NI-3100 User manual

AMX

AMX NetLinx Integrated Controller NI-3100 User manual

AMX NetLinx NI-4000 User instructions

AMX

AMX NetLinx NI-4000 User instructions

AMX AXP-PLV POSITRACK PILOT VIDEO TOUCH PANEL User manual

AMX

AMX AXP-PLV POSITRACK PILOT VIDEO TOUCH PANEL User manual

Popular Controllers manuals by other brands

Digiplex DGP-848 Programming guide

Digiplex

Digiplex DGP-848 Programming guide

YASKAWA SGM series user manual

YASKAWA

YASKAWA SGM series user manual

Sinope Calypso RM3500ZB installation guide

Sinope

Sinope Calypso RM3500ZB installation guide

Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

Isimet

Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

LSIS sv-ip5a user manual

LSIS

LSIS sv-ip5a user manual

Airflow Uno hab Installation and operating instructions

Airflow

Airflow Uno hab Installation and operating instructions

ABB ACS580-01 drives Hardware manual

ABB

ABB ACS580-01 drives Hardware manual

Panasonic GM1 Series Reference manual

Panasonic

Panasonic GM1 Series Reference manual

Emerson SW93 owner's manual

Emerson

Emerson SW93 owner's manual

AutoAqua Smart ATO micro SATO-120P manual

AutoAqua

AutoAqua Smart ATO micro SATO-120P manual

Panasonic FP? Positioning Unit RTEX Technical manual

Panasonic

Panasonic FP? Positioning Unit RTEX Technical manual

Alpha IP MIOB 21001 manual

Alpha IP

Alpha IP MIOB 21001 manual

Siemens OpenAir GMA 1 Series Mounting instructions

Siemens

Siemens OpenAir GMA 1 Series Mounting instructions

Surecom SR-629 user manual

Surecom

Surecom SR-629 user manual

Regulus SRS1 T Installation and operation manual

Regulus

Regulus SRS1 T Installation and operation manual

3M MicroTouch EX113 reference guide

3M

3M MicroTouch EX113 reference guide

KUHN TKS user manual

KUHN

KUHN TKS user manual

S&C PMH Instructions for operation

S&C

S&C PMH Instructions for operation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Installation Sheet
RDC-PDC Control Card, Dual or Three Phase
(120 or 240 VAC)
The RDC-PDC Control Card module controls up to six dimmable channels
with six satellite connectors (for RDM series dimmer or switching modules).
The RDC-PDC is controlled by AXlink, PROlink, or by dry contact closures.
The RDC-PDC is designed for use with Radia enclosures, in a modular dig-
ital dimming system. The module's 120 and 240 VAC ratings are CE, UL,
and C-UL approved.
RDC-PDC UL and C-UL Ratings:
Control Input:
• AXlink
• PROlink
• Eight dry closures
Control Output:
• Six control ports
• Max. total control current at 300 mA
Power Inputs:
• Line 1 (channel 1 and 4)
• Line 2 A (channel 5)
• Line 2B (channel 2)
• Line 3 (channel 3 and 6)
• Neutral
Specifications:
• Dimensions (HW): 10.0" x 2.75" (254.0 mm x 69.85 mm)
• 12 VDC power (optional)
• Torque terminals to 20 in-lbs. (2.3 N/M)
• Max. wire size: 10 AWG
• Wire stripping length: 0.28" (7 mm)
• Weight: 1.5 lbs. (0.68 kg)
• Power consumption: 50 mA @ 120 VAC
25 mA @ 240 VAC
Button/Jumper Information:
• RESET button: By pressing the RESET button, located on the RDC-
PDC circuit board, it is possible to restart the processor without having
to power-down the unit or disconnect AXlink or PROlink. RESET does
not affect saved presets or curve settings.
• MEMORY PROTECT on/off jumper: The MEMORY PROTECT
jumper is set to Off by default. To protect saved curve settings and pre-
sets from accidental recording, put the jumper in the On position.
Caution: Pre-Installation Notes
• All Class 1 wiring must be connected to proper terminals.
• All control wiring must be connected to proper terminals.
• Disconnect power while installing or connecting the unit.
• Keep the top and bottom air vents clear at all times.
• Test loads for shorts before connecting.
• Use low-voltage wires with a 300 volt rating or greater.
• Use field-installed copper conductors.
• All electrical ratings are for continuous duty.
• For indoor use only.
• AC lighting loads only.
Connecting RDM Series to the AMX Lighting Master
Connecting AXlink
Connect the 4-pin captive-wire AXlink connector from the RDC-PDC to the
Central Controller for AXlink control of the dimming system.
Connecting PROlink:
Connect the orange 4-pin captive-wire PROlink connector from the RDC-
PDC to a PRO-DP8 PROlink wall panel.
FIG. 1 RDC-PDC control card
Line inputs
(factory wired)
Mounting
points
Reset button
Memory Protect
jumper
AXlink connector
PROlink connector
LED indicators
Control ports
Dry closure
contacts
AXlink DIP
switch
PROlink DIP
switch
FIG. 2 Connecting RDM series
FIG. 3 AXlink wiring
FIG. 4 PROlink wiring
Pin 4 (GND)
Pin 3 (RLY)
Pin 2 (DIM)
Pin 1 (+12 V)
RDC-PDC 4-pin module connector
4-pin plug from a RDM series module
Note: The 4-pin plugs from the module
connector to the 4-pin connector on the
master (black plug cover facing up).
PWR
AXP
AXM
GND
PWR
AXP
AXM
GND
Central
RDC-PDC Controller
(optional)
PRO-DP8 Pack 1 Pack 2
+12
PR+
PR-
GND
+12
PR+
PR-
GND
2RDC-PDC Control Card, Dual or Three Phase
Connecting Dry Closures
Use the 8 (+ common) dry closures with a WPD8 eight-button wall panel.
Each contact closure connection (1 - 8) is pre-programmed with a default
preset. The table below shows the default presets for each contact clo-
sure.
Setting AXlink and PROlink Address Numbers:
Lighting Application Drawings
FIG. 5 Dry closures connection
Dry Closure Default Presets
Contact Closure Default Function
1 Channel 1 at 100% in 1 second
2 Channel 2 at 100% in 1 second
3 Channel 3 at 100% in 1 second
4 Channel 4 at 100% in 1 second
12345678
COM Each contact (1 - 8) is pre-
programmed with a default preset.
Refer to the AMX Lighting Control
System instruction manual for
details on dry closure default presets
and recording new presets.
Dry Closure Default Presets (Cont.)
5 Channel 5 at 100% in 1 second
6 Channel 6 at 100% in 1 second
7 Pack on (channels 1-6)
8 Pack off (channels 1-6
All other channels are undefined.
FIG. 6 Setting AXlink and PROlink address numbers.
AXlink Address PROlink Address
Te s t
Set the AXlink address number
(1-255) for the RDC-DC. This
number must match the device
number in your Axcess program.
Use the PROlink DIP switch to set
the PROlink address number for the
RDC-DC (1-10).
Pin 8 on the PROlink DIP switch is
a test switch that turns all circuits on
to full.
FIG. 7 Method A
Method A
RDC-PDC/120, 3 Phase
6 dimmers, 0 switches
RDC-PDC Control Card, Dual or Three Phase 3
FIG. 8 Method B
FIG. 9 Method C
FIG. 10 Method D
Method B
RDC-PDC/120
3-phase, 6 switches
Method C
Three phase,
120/208 VAC,
4 wire + G
THREE PHASE, 120/208 VAC, 4W + G
PHASE A - Controls Dimmers 1 and 4
PHASE B - Controls Dimmers 2 and 5
PHASE C - Controls Dimmers 3 and 6
Method D
Three phase,
120/208 VAC
5 wire +G
THREE PHASE, 120/208 VAC, 5W + G
PHASE A - Controls Dimmers 1 and 4
PHASE B1 - Controls Dimmer 5
PHASE B2 - Controls Dimmer 2
PHASE C - Controls Dimmers 3 and 6
AMX Corporation reserves the right to alter specifications without notice at any time.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
043-019-2193 8/01 ©2001 AMX Corporation. All rights reserved.
The AMX logo is a trademark of AMX Corporation. AMX Corporation reserves the right to alter specifications without notice at any time.
3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993