Andersen VeriLock User manual

Parts Included / Partes Incluidas
(1) Instruction Guide / Instruction Guide
(4) VeriLock Face Plate / VeriLock Face Plate
(1) VeriLock Sensor / VeriLock Sensor
(1) Actuator / Actuator
(2) CR-2032 Battery / CR-2032 Battery
(1) Cylinder Magnet / Cylinder Magnet
(1) Block Magnet / Block Magnet
(2) Cylinder Magnet Cap/ Cylinder Magnet Cap
(2) Block Magnet Cap/ Block Magnet Cap
(2) Screw Standoff / Screw Standoff
(1) 4-1/4" Spindle / 4-1/4" Spindle
(4) #8 x 1-3/4" Bolt (2 white, 2 stone)
(Tribeca® Hardware Only) /
#8 x 1-3/4" Bolt (2 white, 2 stone)
(Tribeca® Hardware Only)
9139831 BA-0 1 Revised 02/21/16
VeriLock®Security Sensor Application
VeriLock®Security Sensor Application
▶Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.
Lea completamente la guía antes de comenzar la instalación. Lea y respete todas las advertencias y precauciones durante la instalación de la unidad.
▶Check with your local building code ofcial to identify and conrm compliance with local building code requirements.
Consulte los códigos locales de construcción para identicar y conrmar que se cumplan los requisitos del código de construcción.
Thank you for choosing Andersen. / Gracias por elegir Andersen.
“Andersen” and all other marks where denoted are trademarks of Andersen Corporation and its subsidiary. © 2016 Andersen Corporation. All rights reserved.
“Andersen” y todas las demás marcas que aparezcan son marcas registradas de Andersen Corporation y su subsidiaria © 2016 Andersen Corporation. Todos los derechos reservados.
for Andersen®A-Series Frenchwood Hinged Inswing & Outswing, 400 Series Frenchwood®Hinged Inswing &
Outswing and Hinged Inswing & Outswing Entry Doors
for Andersen®A-Series Frenchwood Hinged Inswing & Outswing, 400 Series Frenchwood®Hinged Inswing &
Outswing and Hinged Inswing & Outswing Entry Doors
For questions call 1-888-888-7020. For more information and/or guides visit andersenwindows.com.
Please leave this guide with building owner.
Si tiene alguna pregunta llame al 1-888-888-7020. Para obtener más información y/o guías, visite andersenwindows.com.
Deje esta guía con el dueño de la construcción.
VeriLock®
Face Plate
VeriLock®
Face Plate
VeriLock®
Sensor
VeriLock®
Sensor
Screw Standoff
Screw Standoff
Block
Magnet
Block
Magnet
Depending on individual installation requirements, some parts may not be used.
Depending on individual installation requirements, some parts may not be used.
Cylinder
Magnet
Cylinder
Magnet
Cylinder
Magnet Cap
Cylinder
Magnet Cap
CR-2032
Battery
CR-2032
Battery
Actuator
Actuator
Block
Magnet Cap
Block
Magnet Cap
Additional Parts Required for
Entry Doors Only (Ordered Seperately)
Additional Parts Required for
Entry Doors Only (Ordered Seperately)
(1) Extended Lock Actuator /
Extended Accionador del cerrojo
#8 x 1-3/4" Bolt
(Tribeca Hardware Only)
#8 x 1-3/4" Bolt
(Tribeca Hardware Only)
4-1/4"
Spindle
4-1/4"
Spindle
Tools Needed / Herramientas Necesarias
∙Safety Glasses / Lentes de seguridad
∙Phillips Screwdriver / Destornillador Phillips
∙1/8" Hex Key / Hex Key de 1/8"
∙Drill/Driver / Taladro/destornillador
∙5/16" Drill Bit / Broca para taladro de 5/16"
∙Tape Measure / Tape Measure
∙Drop Cloth / Drop Cloth

2
9139831
Use caution when working at elevated heights and around unit openings.
Follow manufacturers’ instructions for ladders and/or scaffolding. Failure
to do so may result in injury or death.
Sea cauteloso al trabajar en lugares elevados y cerca de las aberturas de
la unidad. Siga las instrucciones del fabricante para el uso de escaleras
y/o andamios. Si no lo hiciera, podrían producirse lesiones o la muerte.
Follow manufacturers’ instructions for hand or power tools. Always
wear safety glasses. Failure to do so may result in injury and/or
product damage.
Siga las instrucciones del fabricante para el uso de herramientas
eléctricas o manuales. Utilice siempre gafas de seguridad. Si no lo
hiciera, podrían producirse lesiones y/o daños al producto.
Batteries carry the risk of re, explosion and burns. Do not recharge,
disassemble, heat above 212 degrees F (100 degrees C) or
incinerate. Dispose of used batteries promptly and properly. Keep
away from children.
Les piles représentent un risque d’incendie, d’explosion et de
brûlures. Ne pas recharger, démonter, chauffer à une température
excédant 100degrés C (212degrésF) ou incinérer. Éliminer les piles
rapidement et de manière appropriée. Garder à l’écart des enfants.
Magnets are small parts and, if swallowed, could pose a choking
hazard to young children.
Los imanes son partes pequeñas que, en caso de ingesta, pueden
representar un riesgo de asxia para niños pequeños.
Magnetic eld can be harmful to implanted medical device wearers.
Keep magnets away from devices.
Magnetic eld can be harmful to implanted medical device wearers.
Keep magnets away from devices.
Batteries are small parts and, if swallowed, could pose a choking
hazard to young children.
Las baterías son partes pequeñas que, en caso de ingesta, pueden
representar un riesgo de asxia para niños pequeños.

3
9139831
1
Interior
Lay a drop cloth down to prevent losing parts. Unlock and open active door panel. Loosen set
screw on exterior handle using 1/8" hex key. Remove handles and set aside for reuse.
Lay a drop cloth down to prevent losing parts. Unlock and open active door panel. Loosen set
screw on exterior handle using 1/8" hex key. Remove handles and set aside for reuse.
3
Interior
Loosen cylinder mounting bolts until exterior components can
be removed. Set exterior components aside for reuse.
Loosen cylinder mounting bolts until exterior components can
be removed. Set exterior components aside for reuse.
Dummy Cylinder
Falso cilindro
Cylinder
Mounting Bolts
(do not fully remove)
Pernos de montaje
del cilindro
(do not fully remove)
Exterior Active
Escutcheon
Escudete
con apertura
exterior
Gasket
Junta
Lock Mechanism
Mecanismo del
cerrojo
Support exterior components when loosening cylinder mounting bolts.
Support exterior components when loosening cylinder mounting bolts.
Remove escutcheon bolts and interior active
escutcheon. Set aside for reuse.
Remove escutcheon bolts and interior active
escutcheon. Set aside for reuse.
Exterior Handle
Manija exterior
Interior Handle
Manija interior
Set Screw
Tornillo de jación
1/8" Hex Key
Hex Key de 1/8" Bushing
Casquillo
Bushing
Casquillo
Spindle
Husillo
2
Interior
Escutcheon
Bolt
Perno de
escudete
Interior Active
Escutcheon
Escudete con
apertura interior
For Entry Doors only, remove cylinder mounting bolts, limiting plate and
lock actuator. Replace existing lock actuator with extended lock actuator.
Reapply parts as shown, do not fully tighten bolts.
For Entry Doors only, remove cylinder mounting bolts, limiting plate and
lock actuator. Replace existing lock actuator with extended lock actuator
and reapply parts as shown, do not fully tighten bolts.
Entry Doors Only /Entry Doors Only
Lock Actuator
Lock Actuator
Cylinder Mounting Bolts
Pernos de montaje del cilindro
Limiting Plate
Placa limitadora
Existing
Lock Actuator
Existing
Lock Actuator
Extended
Lock Actuator
Extended
Lock Actuator

4
9139831
4
Interior
Apply screw standoffs to mounting studs on back side of exterior
escutcheon as shown.
Apply screw standoffs to mounting studs on back side of exterior
escutcheon as shown.
Re-apply exterior components and tighten cylinder
mounting bolts.
Re-apply exterior components and tighten cylinder
mounting bolts.
Screw Standoff
Screw Standoff
Screw Standoff
Screw Standoff
Exterior Active
Escutcheon
Escudete
con apertura
exterior
Verify gasket is
seated properly.
Verify gasket is
seated properly.
Cylinder
Mounting
Bolts
Pernos de
montaje del
cilindro
Mounting Stud
Mounting Stud
Mounting Stud
Mounting Stud
Dummy Cylinder
Falso cilindro
Exterior Active
Escutcheon
Escudete
con apertura
exterior
Removable
Mounting Stud
Removable
Mounting Stud
Screw Standoff
Screw Standoff
Screw Standoff
Screw Standoff
Removable
Mounting Stud
Removable
Mounting Stud
For Tribeca hardware only, apply removable mounting studs as shown,
then apply screw standoffs to mounting studs on back side of exterior
escutcheon as shown.
For Tribeca hardware only, apply removable mounting studs as shown,
then apply screw standoffs to mounting studs on back side of exterior
escutcheon as shown.
Verify gasket is
seated properly.
Verify gasket is
seated properly.
Exterior Active
Escutcheon
Escudete
con apertura
exterior
6
Interior
Select preferred color VeriLock face plate. Press sensor into back side of face plate and
install batteries with (+) facing out as shown. Indicator light will illuminate for one (1)
second when batteries are installed correctly.
Select preferred color VeriLock face plate. Press sensor into back side of face plate and
install batteries with (+) facing out as shown. Indicator light will illuminate for one second
when batteries are installed correctly.
(back views)
(back views)
VeriLock® Assembly
VeriLock® Assembly
VeriLock
Face Plate
VeriLock
Face Plate
VeriLock Sensor
VeriLock Sensor
CR-2032
Batteries
CR-2032
Batteries
5
Interior
(front view)
(front view)
Indicator
Light
Indicator
Light
Tribeca®Hardware Only
Tribeca®Hardware Only

5
9139831
7
Interior
8
Interior
Verify panel surface is clean and dry. Position VeriLock assembly on the panel over the lock actuator as shown. The indicator will illuminate for one (1)
second when the sensor is applied to the panel as the anti-tamper switch is depressed.
Verify panel surface is clean and dry. Position assembly on the panel over the lock actuator as shown. The indicator will illuminate for one (1) second
when the sensor is applied to the panel as the anti-tamper switch is depressed.
Rotate VeriLock assembly to the correct orientation (tab side must point toward the latch side of panel). Insert actuator into top hole of VeriLock
assembly from back side as shown.
Rotate VeriLock assembly to the correct orientation. (tab side must point toward the latch side of panel).
Tab side as
viewed from
back.
Tab side as
viewed from
back.
Top Hole
Top Hole
VeriLock Assembly
VeriLock Assembly
Lock Actuator
Accionador del
cerrojo
Actuator
Accionador
Actuator
(in top
hole only)
Actuator
(in top
hole only)
Alignment Tabs
(will fit in only
one orientation)
Alignment Tabs
(will fit in only
one orientation)
(Verify arrows
align on the tab
side as shown)
(Verify arrows are
aligned as shown
on the tab side)
VeriLock® Assembly
(tab must point toward
latch side of panel)
VeriLock® Assmbly
(tab must point toward
latch side of panel)
VeriLock assembly can be rotated for use on either
left handed (LH) or right handed (RH) panels.
VeriLock assembly can be rotated for use on either
left handed (LH) or right handed (RH) panels.
Latch
Latch
Tab
Tab
VeriLock® Assembly
(back view)
VeriLock® Assmbly
(back view)
VeriLock Sensor
(anti-tamper switch)
VeriLock Sensor
(anti-tamper switch)
Sensor contains an anti-tamper switch.
Do not apply sensor over wet nish or
rough/dirty surface. Improper switch
function may result.
Sensor contains an anti-tamper switch.
Do not apply sensor over wet nish or
rough/dirty surface. Improper switch
function may result.
Indicator Light
Indicator Light

6
9139831
Handles must point
toward the glass with set
screw on the bottom.
Las manijas deben
apuntar hacia el vidrio
con el tornillo de jación
en la parte inferior.
Slide handles and bushings together tightly. Insert set screw in exterior handle and tighten using hex key. Finish tightening escutcheon bolts.
Slide handles and bushings together tightly. Insert set screw in exterior handle and tighten using hex key. Finish tightening escutcheon bolts.
Position interior escutcheon on panel as shown and fasten bolts (do not fully tighten until handles have been installed).
Position interior escutcheon on panel as shown and fasten bolts (do not fully tighten until handles have been installed).
9
Interior
Loosen set screw on handle and remove spindle. Replace existing spindle with 4-1/4"spindle and tighten set screw. Set screw must enter v-slot in
spindle when securing the handle.
Loosen set screw on handle and remove spindle. Replace existing spindle with extended spindle and tighten set screw. Set screw must enter v-slot in
spindle when securing the handle.
Escutcheon
Bolt
Perno de
escudete
Interior Active
Escutcheon
Escudete con
apertura interior
10
Interior
Spindle
Husillo
Exterior Handle
Manija exterior
Interior Handle
Manija interior
Set Screw
Tornillo de
jación
Hex Key
Hex Key Bushing
Casquillo
Bushing
Casquillo
Line up v-slot
with set screw
Alinee la ranura
en forma de V
con el tornillo de
fijación
Spindle (V-Slot)
Husillo (ranura en
forma de V)
Set Screw
Tornillo de jación
11
Interior
Bottom View/
Vista inferior
Spindle
Husillo
Tribeca®Hardware Only
Tribeca®Hardware Only
Replace existing bolts
with #8 x 1-3/4" bolts.
Replace existing bolts
with #8 x 1-3/4" bolts.
#8 x 1-3/4" Bolt
#8 x 1-3/4" Bolt
Hex Key
Hex Key
4-1/4" Spindle
4-1/4" Spindle
Existing Spindle
Existing Spindle

7
9139831
Magnet Application/ Magnet Application
▶For DOUBLE operating, OUTSWING doors, go to Step 12a.
For DOUBLE operating, OUTSWING doors, go to Step 12a.
▶For DOUBLE operating, INSWING doors, go to Step 12b.
For DOUBLE operating, INSWING doors, go to Step 12b.
▶For SINGLE operating, OUTSWING doors, go to Step 12c.
For SINGLE operating, OUTSWING doors, go to Step 12c.
▶For SINGLE operating, INSWING doors,
go to Step 12d.
For SINGLE operating, INSWING doors,
go to Step 12d.
Magnets are small parts and, if swallowed, could pose a choking hazard to young children.
Los imanes son partes pequeñas que, en caso de ingesta, pueden representar un riesgo de asxia para niños pequeños.
Determine door your conguration and proceed to appropriate section for magnet installation.
Determine door your conguration and proceed to appropriate section for magnet installation.
Selection of the correct door conguration is critial for magnet application. Wrong conguration selection will result in
improper magent application and product damage.
Selection of the correct door conguration is critial for magnet application. Wrong conguration selection will result in
improper magent application and product damage.
Or
Or
Or
Or
Or
Or
As viewed from
the exterior.
As viewed from
the exterior.
As viewed from
the exterior.
As viewed from
the exterior.
As viewed from
the exterior.
As viewed from
the exterior.
As viewed from
the exterior.
As viewed from
the exterior.
12
Stationary Panel
Stationary Panel
Stationary Panels
Stationary Panels

Order Designation Description
Viewed from the exterior. Viewed fromthe exterior.
Order Designation Description
Viewed fromthe exterior.
6068 S A L
Door Rough
Opening
Stationary
Panel
Active
Panel
Left
Hinged
6068 A S R
Door Rough
Opening
Active Panel
Stationary
Panel
Right
Hinged
Door Rough
Opening
Active Panel
(panel used
most often)
Passive
Panel
Left
Hinged
Right
Hinged
Door Rough
Opening
Stationary
Panel
Active
Panel
Stationary
Panel
Right
Hinged
6068 A P L R 9068 S A S R
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH Frenchwood Hinged Patio Doors - Inswing
FWH Frenchwood Hinged Patio Doors - Outswing
Door Rough
Opening
Active Panel
(panel used
most often)
Passive
Panel
Left
Hinged
Right
Hinged
6068 A P L R
FWO
Frenchwood®
Hinged Outswing
Patio Door
Left Hinged
(hinges on left)
Active Panel
(operating panel
used most often)
Passive Panel
(operating panel with
attached astragal)
Stationary
(non-operating panel)
Right Hinged
(hinges on right)
8
9139831
Install magnet on your DOUBLE operating, OUTSWING, door as shown.
Install magnet on your DOUBLE operating, OUTSWING, door as shown.
As viewed from
the exterior.
As viewed from
the exterior.
Cylinder Magnet
Cylinder Magnet
Press cylinder magnet rmly into
preferred color cylinder magnet cap.
Press cylinder magnet rmly into
preferred color cylinder magnet cap.
Cylinder
Magnet Cap
Cylinder
Magnet Cap
Interior View
Interior View
For DOUBLE Operating, OUTSWING Doors Only
For DOUBLE Operating, OUTSWING Doors Only
12a
Close doors and lightly mark
magnet location across from
bottom arrow on VeriLock face
plate, as shown.
Close doors and lightly mark
magnet location across from
bottom arrow on VeriLock face
plate, as shown.
Open active panel and drill 5/16"
hole at marked location in center
of astragal side, as shown.
Open active door and drill 5/16"
hole at marked location in center
of side surface, as shown.
Insert cylinder magnet with
cap into drilled hole.
Insert cylinder magnet with
cap into drilled hole.
5/16" Drill Bit
5/16" Drill Bit
Passive Panel
Passive Panel
Astragal
Astragal
Astragal
Astragal
Interior View
Interior View
Active Panel
Active Panel
Center of
astragal side.
Center of
astragal side.

9
9139831
12b For DOUBLE Operating, INSWING Doors Only
For DOUBLE Operating, INSWING Doors Only
Order Designation Description
Viewed from the exterior. Viewed fromthe exterior.
Order Designation Description
Viewed fromthe exterior.
6068 S A L
Door Rough
Opening
Stationary
Panel
Active
Panel
Left
Hinged
6068 A S R
Door Rough
Opening
Active Panel
Stationary
Panel
Right
Hinged
Door Rough
Opening
Active Panel
(panel used
most often)
Passive
Panel
Left
Hinged
Right
Hinged
Door Rough
Opening
Stationary
Panel
Active
Panel
Stationary
Panel
Right
Hinged
6068 A P L R 9068 S A S R
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH Frenchwood Hinged Patio Doors - Inswing
FWH Frenchwood Hinged Patio Doors - Outswing
Door Rough
Opening
Active Panel
(panel used
most often)
Passive
Panel
Left
Hinged
Right
Hinged
6068 A P L R
FWO
Frenchwood®
Hinged Outswing
Patio Door
Left Hinged
(hinges on left)
Active Panel
(operating panel
used most often)
Passive Panel
(operating panel with
attached astragal)
Stationary
(non-operating panel)
Right Hinged
(hinges on right)
Position block magnet with cap to front
surface of passive panel, ush to edge, and
centered across from bottom arrow on
VeriLock face plate.
Position block magnet with cap to front
surface of passive panel, ush to edge, and
centered across from bottom arrow on
VeriLock face plate.
Remove adhesive liner from one side of
block magnet and press rmly into
preferred color block magnet cap.
Remove adhesive liner from one side of
block magnet and press rmly into
preferred color block magnet cap.
Block Magnet
Block Magnet
Block Magnet Cap
Block Magnet Cap
Install magnet on your DOUBLE operating, INSWING, door as shown.
Install magnet on your DOUBLE operating, INSWING, door as shown.
As viewed from
the exterior.
As viewed from
the exterior.
Interior View
Interior View
Bottom Arrow
Bottom Arrow
Active Panel
Active Panel
Passive Panel
Passive Panel
Edge of Passive Panel
Edge of Passive Panel Remove second adhesive liner
from block magnet with cap.
Remove second adhesive liner
from block magnet with cap.

10
9139831
12c For SINGLE Operating, OUTSWING Doors Only
For SINGLE Operating, OUTSWING Doors Only
Install magnet on your SINGLE operating, OUTSWING, door as shown.
Install magnet on your SINGLE operating, OUTSWING, door as shown.
Order Designation Description
Viewed from the exterior. Viewed fromthe exterior.
Order Designation Description
Viewed fromthe exterior.
6068 S A L
Door Rough
Opening
Stationary
Panel
Active
Panel
Left
Hinged
6068 A S R
Door Rough
Opening
Active Panel
Stationary
Panel
Right
Hinged
Door Rough
Opening
Active Panel
(panel used
most often)
Passive
Panel
Left
Hinged
Right
Hinged
Door Rough
Opening
Stationary
Panel
Active
Panel
Stationary
Panel
Right
Hinged
6068 A P L R 9068 S A S R
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH Frenchwood Hinged Patio Doors - Inswing
FWH Frenchwood Hinged Patio Doors - Outswing
Door Rough
Opening
Active Panel
(panel used
most often)
Passive
Panel
Left
Hinged
Right
Hinged
6068 A P L R
FWO
Frenchwood®
Hinged Outswing
Patio Door
Left Hinged
(hinges on left)
Active Panel
(operating panel
used most often)
Passive Panel
(operating panel with
attached astragal)
Stationary
(non-operating panel)
Right Hinged
(hinges on right)
Lightly mark magnet location on panel
stop across from bottom arrow on
VeriLock face plate, as shown.
Lightly mark magnet location on panel
stop across from bottom arrow on
VeriLock face plate, as shown.
Open door and drill 5/16"
hole, 1" deep, 1/4" from panel
stop edge.
Open door and drill 5/16"
hole, 1" deep, 1/4" from panel
stop edge.
Insert cylinder magnet with
cap into drilled hole.
Insert cylinder magnet with
cap into drilled hole.
As viewed from
the exterior.
As viewed from
the exterior.
Interior View
Interior View
Interior View
Interior View
Cylinder Magnet
Cylinder Magnet
Press cylinder magnet rmly
into preferred color cylinder
magnet cap.
Press cylinder magnet rmly
into preferred color cylinder
magnet cap.
Cylinder
Magnet Cap
Cylinder
Magnet Cap
Bottom Arrow
Bottom Arrow
Panel Stop
Panel Stop
1/4"
5/16" Drill Bit
5/16" Drill Bit

11
9139831
12d For SINGLE Operating, INSWING Doors Only
For SINGLE Operating, INSWING Doors Only
Install magnet on your SINGLE operating, INSWING, door as shown.
Install magnet on your SINGLE operating, INSWING, door as shown.
Order Designation Description
Viewed from the exterior. Viewed fromthe exterior.
Order Designation Description
Viewed fromthe exterior.
6068 S A L
Door Rough
Opening
Stationary
Panel
Active
Panel
Left
Hinged
6068 A S R
Door Rough
Opening
Active Panel
Stationary
Panel
Right
Hinged
Door Rough
Opening
Active Panel
(panel used
most often)
Passive
Panel
Left
Hinged
Right
Hinged
Door Rough
Opening
Stationary
Panel
Active
Panel
Stationary
Panel
Right
Hinged
6068 A P L R 9068 S A S R
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH Frenchwood Hinged Patio Doors - Inswing
FWH Frenchwood Hinged Patio Doors - Outswing
Door Rough
Opening
Active Panel
(panel used
most often)
Passive
Panel
Left
Hinged
Right
Hinged
6068 A P L R
FWO
Frenchwood®
Hinged Outswing
Patio Door
Left Hinged
(hinges on left)
Active Panel
(operating panel
used most often)
Passive Panel
(operating panel with
attached astragal)
Stationary
(non-operating panel)
Right Hinged
(hinges on right)
Order Designation Description
Viewed from the exterior. Viewed fromthe exterior.
Order Designation Description
Viewed fromthe exterior.
6068 S A L
Door Rough
Opening
Stationary
Panel
Active
Panel
Left
Hinged
6068 A S R
Door Rough
Opening
Active Panel
Stationary
Panel
Right
Hinged
Door Rough
Opening
Active Panel
(panel used
most often)
Passive
Panel
Left
Hinged
Right
Hinged
Door Rough
Opening
Stationary
Panel
Active
Panel
Stationary
Panel
Right
Hinged
6068 A P L R 9068 S A S R
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH
Frenchwood®
Hinged Inswing
Patio Door
FWH Frenchwood Hinged Patio Doors - Inswing
FWH Frenchwood Hinged Patio Doors - Outswing
Door Rough
Opening
Active Panel
(panel used
most often)
Passive
Panel
Left
Hinged
Right
Hinged
6068 A P L R
FWO
Frenchwood®
Hinged Outswing
Patio Door
Left Hinged
(hinges on left)
Active Panel
(operating panel
used most often)
Passive Panel
(operating panel with
attached astragal)
Stationary
(non-operating panel)
Right Hinged
(hinges on right)
Open door and mark magnet
location on jamb (even with
bottom strike plate screw
and centered in the area
between the strike plate and
jamb edge).
Open door and mark magnet
location on jamb (even with
bottom strike plate screw
and centered in the area
between the strike plate and
jamb edge).
As viewed from
the exterior.
As viewed from
the exterior.
Cylinder Magnet
Cylinder Magnet
Interior View
Interior View
Interior View
Interior View
5/16" Drill Bit
5/16" Drill Bit
Drill 5/16" hole, 1" deep, at
marked location.
Drill 5/16" hole, 1" deep, at
marked location.
Insert cylinder magnet with
cap into drilled hole.
Insert cylinder magnet with
cap into drilled hole.
Strike Plate
Strike Plate
Edge of jamb.
Edge of jamb.
Jamb
Jamb
Press cylinder magnet rmly
into preferred color cylinder
magnet cap.
Press cylinder magnet rmly
into preferred color cylinder
magnet cap.
Cylinder
Magnet Cap
Cylinder
Magnet Cap

12
9139831
1. Close door without locking. Indicator light will illuminate for one (1) second.
2. Engage all upper, middle and lower hooks and lock door with dead bolt. Indicator light will illuminate for one (1) second.
Verify door is locked.
3. Unlock door with dead bolt. Indicator light will illuminate for one (1) second.
4. Open door. Indicator light will illuminate for one (1) second.
1. Close door without locking. Indicator light will illuminate for one (1) second.
2. Engage all upper, middle and lower hooks and lock door with dead bolt. Indicator light will illuminate for one (1) second.
Verify door is locked.
3. Unlock door with dead bolt. Indicator light will illuminate for one (1) second.
4. Open door. Indicator light will illuminate for one (1) second.
Verify VeriLock® sensor function. If indicator light does not respond as described, verify sensor application and magnet placement.
Verify VeriLock® sensor function. If indicator light does not respond as described, verify sensor application and magnet placement.
Refer to monitoring system of your choice for sensor enrollment. /
Refer to monitoring system of your choice for sensor enrollment.
For maintenance information, please visit http://www.andersenwindows.com/verilock and consult with the VeriLock user guide.
For maintenance information, please visit http://www.andersenwindows.com/verilock and consult with the VeriLock user guide.
▶Procedure is complete.
Procedure is complete.
Verify VeriLock Sensor Function / Verify VeriLock Sensor Function
13
Interior Thumb Turn Latch
Thumb Turn Latch
Unlocked
Unlocked Locked
Locked
Indicator Light
Indicator Light

13
9139831
Federal Communications Commission (FCC)
Part 15 Statement
This device complies with FCC Rules Part 15. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference. (2) This device must accept any
interference that may be received, including interference that
may cause undesired operation.
Industry Canada (IC) RSS Statement
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and (2) This device
must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes: (1)
I'appareil ne doit pas produire de brouillage; (2) I'utilisateur de
I'appareil doit accepter tout brouillage radioélectrique subi,
méme si le brouillage est susceptible d'en compromettre le
fonctionnement.
Changes or modifications not expressly approved by Andersen
may void the user's authority to operate the equipment.
Federal Communications Commission (FCC)
Part 15 Statement
This device complies with FCC Rules Part 15. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference. (2) This device must accept any
interference that may be received, including interference that
may cause undesired operation.
Industry Canada (IC) RSS Statement
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and (2) This device
must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes: (1)
I'appareil ne doit pas produire de brouillage; (2) I'utilisateur de
I'appareil doit accepter tout brouillage radioélectrique subi,
méme si le brouillage est susceptible d'en compromettre le
fonctionnement.
Changes or modifications not expressly approved by Andersen
may void the user's authority to operate the equipment.
Regulatory Statements / Regulatory Statements
Other manuals for VeriLock
7
Other Andersen Security Sensor manuals