Anritsu NF7600 Series User manual

Document No.: NF7600-W014E-5.0
ANRITSU NETWORKS CO., LTD.
Fifth Edition
PureFlow WSX
Unified Network Controller
NF7600 series
WebGUI Operation Manual
TCP Acceleration Edition
For safe and appropriate useof the equipment, please
read this manual before using the equipment.
Additional safety and warning information isprovided
within theUnified Network ControllerOperation
Manual (NF7600-W011E). Please also referto this
document before using the equipment.
Keep themanual with the equipment.

ii
Safety Symbols
To prevent the risk of personal injury or loss related to equipment malfunction, Anritsu Networks Co., Ltd. uses the
following safety symbols to indicate safety-related information. Ensure that you clearly understand themeanings of
the symbols BEFORE using the equipment.
Some or all of the following symbols may be used on all Anritsu Networks Co., Ltd. equipment. In addition, there
may be other labels attached to products that are not shown in the diagrams in this manual.
Symbols used in this manual
This indicates a very dangerous procedure that could result in serious injury or
death if not performed properly.
This indicates a hazardous procedure that could result in serious injury or death if
not performed properly.
This indicates a hazardous procedure or danger that could result in light-to-severe
injury, or loss related to equipment malfunction, if proper precautions are not taken.
Safety Symbols Used on Equipment and in Manual
The following safety symbols are used inside or on the equipment near operation locations to provide information
about safety items and operation precautions. Ensure that you clearly understand the meanings of the symbols
and take the necessary precautions BEFORE using the equipment.
This indicates a prohibited operation. The prohibited operation is indicated
symbolically in or near the barred circle.
This indicates an obligatory safety precaution. The obligatory operation is
indicated symbolically in or near the circle.
This indicates a warning or caution. The contents are indicated symbolically in or
near the triangle.
This indicates a note. The contents are described in the box.
PureFlow WSX
Unified Network Controller NF7600 series
WebGUI Operation Manual
9 March 2016(First Edition)
30 October 2017(Fifth Edition)
Copyright © 2016-2017, ANRITSU NETWORKS CO., LTD.
All rights reserved. No part of this manual may be reproduced without the prior written permission of the
publisher.
The contents of this manual may be changed without prior notice.
Printed in Japan
DANGER
WARNING
CAUTION

iii
Anritsu Networks Co., Ltd. Contac
In the event that this equipment malfunctions, contact an Anritsu Networks
Co., Ltd. Service and Sales office. Contact information can be found on the
last page of the printed version of this manual, and is available in a separate
file on the CD-ROM.
Maintenance Contract
Anritsu Networks Co., Ltd. can provide a range of optional services under a
maintenance contract. For details, contact an Anritsu Networks Co., Ltd.
Service and Sales office.

iv
Notes On Export Management
This product and its manuals may require an Export License/Approval by
the Government of the product's country of origin for re-export from your
country.
Before re-exporting the product or manuals, please contact us to confirm
whether they are export-controlled items or not.
When you dispose of export-controlled items, the products/manuals need to
be broken/shredded so as not to be unlawfully used for military purpose.
Trademark/Registered Trademark
Windows, Internet Explorer, and Microsoft Edge are trademarks or
registered trademarks of Microsoft Corporation in the United States
and/or other countries.
Firefox is a trademark or registered trademark of Mozilla Foundation in
the United States and/or other countries.

I
About This Manual
This manual describes in detail the operation method of WebGUI used in the
PureFlow WSX Unified Network Controller (hereafter referred to as “this
device”).
The applicable models of this equipment are described below.
NF7601A
NF7602A
NF7603A
NF7604A
NF7605A
The manual of this device consists of the following four manuals. This
document is <4>.
<1> Operation Manual TCP Acceleration Edition (NF7600–W011E)
Describes in detail the installation and handling of this device.
<2> Command Reference TCP Acceleration Edition (NF7600–W012E)
Describes in detail the commands used in this device.
<3> Configuration Guide TCP Acceleration Edition (NF7600–W013E)
Describes the basic features of this device and provides specific
examples of the settings required to build a network using these
features.
<4> WebGUI Operation Manual TCP Acceleration Edition (NF7600–
W014E)
Describes the operation for setting and display of this device using a
Web browser.
If the following documents related to this device or other documents
related to the features of this device are issued, be sure to read them:
Release notes
(For details of the issuance of release notes, contact your dealer or an
Anritsu Networks Co., Ltd. customer support center.)

II
Table of Contents
About This Manual .......................................... I
Chapter 1 Overview....................................... 1-1
Chapter 2 Operating Environment................. 2-1
Chapter 3 Operation Method......................... 3-1
3.1 Marks Used in Text..................................................... 3-2
3.2 Notes for Settings....................................................... 3-3
3.3 How to Log In / Log Out.............................................. 3-4
3.4 Screen Configuration.................................................. 3-7
3.5 Setting Flow................................................................ 3-8
3.6 How to Set Channel.................................................... 3-9
3.7 How to Set IP Address of Channel.............................. 3-12
3.8 How to Configure Scenario......................................... 3-14
3.9 Application Acceleration Settings................................ 3-18
3.10 How to Configure Filter ............................................... 3-22
3.11 How to Set Rule List ................................................... 3-26
3.12 How to Perform Settings Related to Time.................... 3-30
3.13 How to Display Traffic Graph of Scenario.................... 3-37
3.14 How to Display Traffic Graph of Network Port.............. 3-42
3.15 How to Display WAN-accel Sessions Graph................ 3-45
3.16 How to Check and Save Configuration........................ 3-50
3.17 How to Check System Log.......................................... 3-54
3.18 How to Check Module Information............................... 3-57
3.19 How to Perform Maintenance Operations.................... 3-58

III
1
2
3

IV.
(Blank page)

1-1
1
Overview
Chapter 1
Overview
This chapter describes overview of WebGUI.
This device is equipped with WebGUI (Graphical User Interface). WebGUI is
an application to perform settings, display and maintenance of this device by
using the Web browser of the network-connected terminal.
The WebGUI system sketch drawing is shown below:
Figure 1.1 WebGUI system sketch drawing
HUB
Terminal
* Connected to the Ethernet port
PureFlow

Chapter 1 Overview
1-2.
WebGUI enables the partial settings, display and maintenance of this
device.
The items that can be set, displayed and maintained by WebGUI are
shown below:
•Items related to network
WebGUI enables the following settings related to the traffic control.
Channel setting
Channel IP address setting
Scenario configuration
Application acceleration configuration
Filter configuration
Rule list setting
•Items related to management
WebGUI enables the following settings related to the device built-in time.
Time zone setting
Daylight-saving time setting
SNTP setting
Manual time setting
•Items related to display
WebGUI enables the following settings.
Scenario traffic graph
Network port traffic graph
WAN accel sessions graph
Configuration
Syslog
Module information
•Items related to maintenance
WebGUI enables the following maintenance.
Uploading software
Restarting the device

2-1
2
Operating Environment
Chapter 2
Operating Environment
This chapter describes the operating environment of WebGUI.
Use WebGUI under the recommended operating environment described
below:
Using under environments other than the recommended operating
environment cannot ensure the WebGUI is operated normally.
Additionally, use the terminal that is not affected by the virus.
•OS
Windows®7
Windows®8.1
Windows®10
•Web browser
Internet Explorer®9.0
Internet Explorer®10.0
Internet Explorer®11.0
Microsoft EdgeTM 20
Firefox®4
•CPU
2.6 GHz or more
•Memory
4 GB or more

Chapter 2 Operating Environment
2-2.
(Blank page)

3-1
3
Operation Method
Chapter 3
Operation Method
This chapter describes how to operate WebGUI.
3.1 Marks Used in Text.....................................................3-2
3.2 Notes for Settings .......................................................3-3
3.3 How to Log In / Log Out..............................................3-4
3.4 Screen Configuration ..................................................3-7
3.5 Setting Flow................................................................3-8
3.6 How to Set Channel....................................................3-9
3.7 How to Set IP Address of Channel ............................3-12
3.8 How to Configure Scenario .......................................3-14
3.9 Application Acceleration Settings ..............................3-18
3.10 How to Configure Filter .............................................3-22
3.11 How to Set Rule List..................................................3-26
3.11.1 How to set rule list group...............................3-26
3.11.2 How to set rule list entry................................3-28
3.12 How to Perform Settings Related to Time..................3-30
3.12.1 How to set time zone.....................................3-31
3.12.2 How to set daylight-saving time.....................3-32
3.12.3 How to set SNTP...........................................3-33
3.12.4 How to set time manually ..............................3-35
3.13 How to Display Traffic Graph of Scenario..................3-37
3.14 How to Display Traffic Graph of Network Port............3-42
3.15 How to Display WAN-accel Sessions Graph..............3-45
3.16 How to Check and Save Configuration......................3-50
3.16.1 How to check configuration ...........................3-50
3.16.2 How to save configuration.............................3-53
3.17 How to Check System Log........................................3-54
3.18 How to Check Module Information.............................3-57
3.19 How to Perform Maintenance Operations..................3-58
3.19.1 How to upload software.................................3-59
3.19.2 How to reboot the device...............................3-62

Chapter 3 Operation Method
3-2
3.1 Marks Used in Text
The following marks are used in this chapter:
" " mark: Indicates the name displayed on the Web browser screen.
[ ] mark: Indicates the point to be clicked (selected) on the Web browser
screen.
[ ] mark: Indicates the name of the reference destination.
" " mark: Indicates a proper name other than those described above.
* mark: Indicates the items to be noted.
Numbers, for example, <1>:
Used when a procedure for the operation on the Web browser
screen is shown related to the operation described in this
chapter.

3.2 Notes for Settings
3-3
3
Operation Method
3.2 Notes for Settings
After settings, be sure to save the setting contents by referring to “3.16.2
How to save configuration”.
The setting detail is reflected without saving it. However, the setting is
deleted when restarting this device.

Chapter 3 Operation Method
3-4
3.3 How to Log In / Log Out
To use WebGUI, the system interface (IP address) of this device must be
configured.
For details of how to set the system interface, refer to [PureFlow WSX
Unified Network Controller NF7600 series Command Reference TCP
Acceleration Edition].
After the completion of system interface setting, start up the Web browser,
and specify the IP address set in the system interface.
* The default value of the system interface is 192.168.1.1.
When the IP address is 192.168.1.1, specify as described below.
http://192.168.1.1
When the connection to this device is successfully established, the login
screen is displayed as shown below.

3.3 How to Log In / Log Out
3-5
3
Operation Method
Enter "admin" in the "Username" column. Enter the adminpassword
which was set for this device in the "Password" column.
If the password was not set, do not fill the "Password" column.
Click the [Login] button for login.
* For details of how to set the password, refer to [PureFlow WSX
Unified Network Controller NF7600 series Command Reference TCP
Acceleration Edition].
Be sure to set the adminpassword for security reasons.
For login by the RADIUS authentication server, enter the RADIUS server
user name in the "UserName" column.
Enter the RADIUS server password in the "Password" column, and click
the [Login] button for login.
When Top Page is displayed as shown below, login has been completed.
Note :
When a channel, a scenario and a filter register the biggest number with
this device, it takes time for operation of login of WebGUI, setting and
display.
When logging in to this device in WebGUI, please set each registration
number of the channel, the scenario and the filter to less than 3000.

Chapter 3 Operation Method
3-6
For logout, click the [Logout] button at upper right of the screen.
If this screen is not operated for 5 minutes, it automatically logs out.
Time taken until the automatic logout is 5 minutes.
* This time cannot be changed.

3.4 Screen Configuration
3-7
3
Operation Method
3.4 Screen Configuration
Selecting the tab on the WebGUI screen switches the screen.
The screens corresponding to the tabs selected are configured as shown
below.
TopPage
Network
Manage.
Monitor
Misc.
Channel················This screen is used for setting channel and IP address of the channel.
Scenario···············This screen is used for the scenario setting.
Filter / Rulelist ········This screen is used for setting the filter and rule list.
Application ············This screen is used for setting the application acceleration.
Time····················This screen is used for the settings related to the time.
Scenario Traffic·······This screen is shows traffic graph of specified scenario.
Network Port Traffic ·This screen is shows traffic graph of network port.
WANAccel Sesions·This screen is shows sessions graph that applied the traffic acceleration.
Config··················This screen shows the setting information of this device and is used for
saving the settings.
Syslog··················This screen shows the system log information of this device.
About···················This screen shows the module information of this device.
···ThisscreenisthetoppageofWebGUI.Thisscreenenablesyoutocheckthemodelnameandmodelnumberofthisdevice.

Chapter 3 Operation Method
3-8
3.5 Setting Flow
The respective setting flows are shown below.
The setting can be performed in orders other than the order shown below.
However, please note that the IP address of the channel can be set only
after setting the channel and that the filter can be set only after setting
the scenario.
WebGUI works with CLI (Command Line Interface) of this device.
Therefore, understanding the command specifications enables you to set
the WebGUI smoothly.
For details of the command specifications, refer to [PureFlow WSX
Unified Network Controller NF7600 series Command Reference TCP
Acceleration Edition].
STEP 1
Set the channel.
Related CLI command
Set WebGUI.
STEP 2
Set the IP address of the
channel.
STEP 3
Configure the scenario.
STEP 4
Configure the filter and rule list
(as required).
add channel
delete channel
show channel
set ip channel
unset ip channel
show ip channel
add scenario
update scenario
delete scenario
show scenario
add filter
delete filter
show filter
add rulelist group
add rulelist entry
delete rulelist group
delete rulelist entry
show rulelist
Descri
ption
Set the channel required for the bridge operation
between desired 2 ports.
Specify 1 port each on the LAN side and WAN side of
1 channel.
Set the IP address for the channel set in STEP 1.
Set the scenario required for the traffic control.
Set the filter criteria to classify the packet.
Set the filter for the scenario set in STEP 3.
Additionally, create the rule list with the packet
classification grouped, as required, and set the list as a
filter.
This manual suits for next models
6
Table of contents