ISO 9000:2001 certified. MBCMA50-SPEC-04-0308-A4. ©2008 Anritsu. All Rights Reserved. Page 1 of 4
CMA50 SPECIFICATIONS
Loss Test Sets, Light Sources, Power Meters
Fast, accurate, and easy-to-use, Anritsu’s CMA50 Family helps assure your loss budgets are met without burdening your
operating budget. Available as light sources, power meters, and the all-in-one loss test set, the entire family is designed for
simplicity, efficiency, and reliability. Based on real-life field experiences and backed by Anritsu’s standard three year warranty,
the CMA50 will provide years of use in a variety of applications including FTTx networks, campus LANs, long-haul
telephony, and CATV distribution.
The CMA50 Family makes your measuring experience simple and error free, and includes pass or fail threshold analysis, large
capacity for test results storage, and an Ethernet network testing option. In addition, when equipped with the EZ-Test option,
CMA50 Loss Test Sets will automatically perform bi-directional end-to-end loss measurements at each selected wavelength,
process the results, and present them on both units in just a few seconds.
Delivering the right performance, features and options, the CMA50 is the ideal tool for installation, test, and maintenance of
fiber networks without the increased cost of extra features that don't provide extra benefits. Designed with your needs in mind,
this lightweight, rugged family is built for the most demanding cable installation environments and will provide years of
valuable service.
Key Benefits
•Allows testing of end-to-end PON links with a single operator.
•Up to 4 high power sources per unit out of a single port.
•EZTest one button auto bi-directional measurement option.
•Pass or fail indicators for in-field compliance.
•Rugged design provides years of use in the most challenging environments.
•Stores up to 100,000 data sets (4 MB of user data).
•Optional Visual Fault Locator (Standard on all Loss Test Set models)
•LAN Access and network testing option via RJ45 port.
•File Transfer via USB port.
•Three year standard warranty.
KEY FEATURES
•One button automated multi-wavelength
bi-directional measurement option
•Calibrated CWDM wavelengths
•Interchangeable connectors for easy testing in
different situations
•Wizard driven for simplified set- ups and use
•Selectable modes to meet any testing requirement
•Ethernet testing option
•Rugged, lightweight, cost-effective to own and use
ISO 9000:2001 certified. MBCMA50-SPEC-04-0308-A4. ©2008 Anritsu. All Rights Reserved. Page 2 of 4
General Family Specifications
Power 4 x AA Alkaline Batteries or Rechargeable NiMH battery pack, 110/220Vac Adapter
Battery Life 20 hours, typical
Auto Shut-Off Programmable (1 to 99 minutes) or disabled
Connector Ports - Sources Universal Latching connector with choice of adapter
Connector Ports - Meters Universal Screw-type connector with choice of adapter
Dimensions 210 x 110 x 41 mm (8.3 x 4.3 x 1.6 in)
Weight <910g (including batteries) depending on configuration
Operating Temperature -10°C to +50°C (+14°F to 122°F)
Storage Temperature -25°C to +60°C (-13°F to 140°F)
Warranty 3 years
Light Sources
Multimode
Center Wavelength1 850nm 1300nm
Wavelength Accuracy +/- 20nm +30/-20nm
Emitter Type LED LED
Output Power (62.5/125 µm fiber) -20dBm -20dBm
Source Linewidth (FWHM) <50nm <200nm
Stability (1 hour)2 +/-0.1dB +/-0.1dB
Output Modes CW (Continuous Wave), 270Hz, 1KHz, 2KHz Modulation
Singlemode
Center Wavelength1 1310nm 1490nm 1550nm 1625nm
Wavelength Accuracy +/- 20nm +/- 20nm +/- 20nm +/- 20nm
Emitter Type Laser Diode Laser Diode Laser Diode Laser Diode
Output Power (G.652 fiber) -7dBm -7dBm -7dBm -7dBm
Source Linewidth (FWHM) <5nm <5nm <5nm <5nm
Stability (1 hour)2 +/- 0.05dB +/- 0.05dB +/- 0.05dB +/- 0.05dB
Output Modes CW (Continuous Wave), 270Hz, 1KHz, 2KHz Modulation
Visual Fault Locator (Standard on Loss Test Set Models, Option V for Light Source and Power Meter Models)
Center Wavelength1 650nm +/- 20nm
Emitter Type Laser Diode
Output Power 1mW (0dBm) Max, 0.8mW (-1.0dBm) Typ
Output Modes CW (Continuous Wave), 2Hz Modulation
Power Meters
Model Standard CATV (Option C)
Wavelengths of Operation 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm plus
CWDM wavelengths from 1270nm to 1610nm in 20nm increments
Detector Type InGaAs
Measurement Range -75dBm to +10dBm -50dBm to +27dBm
Measurement Accuracy3,4,7 +/-0.2dB with Pin = -65dBm to +5dBm +/-0.2dB with Pin = -37dBm to +27dBm
Linearity5+/-0.1dB +/-0.1dB
Maximum Input Power6,7 +10dBm +27dBm
Modulation Detection8 270Hz, 1KHz, and 2KHz
Wavelength Detection Automatic recognition of calibrated wavelengths
(when used in conjunction with a CMA50 light source)
Display Resolution 0.01 (mW, µW, nW, dBr, dBm)
Auto Bi-Direction Test Mode (Available as Option B on Loss Test Set Models only)
Wavelengths All Equipped Singlemode Wavelengths
Link Loss Range150dB (approximately 200km at 1550nm)
Link Loss Accuracy1+/-0.25dB excluding connector pair uncertainty
Testing Time 2.5 seconds per wavelength
ISO 9000:2001 certified. MBCMA50-SPEC-04-0308-A4. ©2008 Anritsu. All Rights Reserved. Page 3 of 4
Optical Return Loss (ORL) Measurements (Option O)
Wavelengths All Equipped Singlemode Wavelengths
ORL Range10 to 55dB
ORL Accuracy1+/-0.75dB with Pin = 0dB to +50dB
Derates above Pin =+50dB to +/-1.5dB at +55dB
ORL Stability1+/-0.5dB at 20dB +/- 0.5dB
Options
V Option9
Visual Fault Locator
Visible light source at 650 nm allowing to visually detect a fiber fault
up to 5 km.
N Option
Network Test
LAN access and network level continuity and frame time delay through
TCP/IP protocol over its built-in 10/100 Mbps Network Interface Card.
B Option
EZTest
Avalable on Loss Test Set configurations, provides one button multiple
wavelength automatic bi-directional measurement. When readings are taken
between two EZ Test equipped units, this feature automatically takes loss
measurements at all wavelengths in each direction, and presents the combined
results on both units.
O Option
ORL with EZ Test
Optical Return Loss (ORL) option allows the measurement of optical return loss
readings required for high speed transmission systems. This option
automatically includes EZ Test Option B as described above.
Notes:
1Typical at +23°C.
2After 10 minute warm-up period.
3At time of calibration. Calibration conditions: 1310nm, -10dBm, +23°C.
4Accuracy derates below 1000nm. At 850nm, Measurement Accuracy is +/-0.35dBm with
Pin= -60dBm to +5dBm (or Pin = -32dBm to +27dBm for CATV Option C units).
5At +23°C, from -65dBm to +2dBm (or -37dBm to +23dBm for CATV Option C units).
6 Do not exceed maximum input power.
7If the power meter is routinely used to measure optical signals in excess of 0dBm (+20dBm for Option C),
more frequent calibration is recommended to insure measurement accuracy.
8P
in ≥-50dBm
9Visual Fault Locator is Standard on all Loss Test Set Models
Available Configurations
Multimode Sources Singlemode Sources Available Options
Model
Number 850nm 1300nm 1310nm 1490nm 1550nm 1625nm
Power
Meter VFL Network EZ Test & ORL
CMA50 Light Sources
50LS35 X X no yes yes no
50LS83 X X no yes yes no
50LS345 X X X no yes yes no
50LS356 X X X no yes yes no
50LS3456 X X X X no yes yes no
50LS8335 X X X X no yes yes no
CMA50 Loss Test Sets (Combined Light Source & Power Meter, and includes Visual Fault Locator)
50LTS35 X X yesa Std yes yes, B or O
50LTS83 X X yesa Std yes yes, B or O
50LTS345 X X X yesa Std yes yes, B or O
50LTS356 X X X yesa Std yes yes, B or O
50LTS3456 X X X X yesa Std yes yes, B or O
50LTS8335 X X X X yesa Std yes yes, B or O
CMA50 Power Meters
50PMS no no no no no no Standard yes yes no
50PMC no no no no no no CATV yes yes no
aCMA50 Loss Test Sets can be ordered with Standard or CATV (Option C) Power Meter
ISO 9000:2001 certified. MBCMA50-SPEC-04-0308-A4. ©2008 Anritsu. All Rights Reserved. Page 4 of 4
Anritsu Corporation
5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan
Phone: +81-46-223-1111
Fax: +81-46-296-1264
•U.S.A.
Anritsu Company
1155 East Collins Blvd., Suite 100, Richardson,
TX 75081, U.S.A.
Toll Free: 1-800-ANRITSU (267-4878)
Phone: +1-972-644-1777
Fax: +1-972-671-1877
•Canada
Anritsu Electronics Ltd.
700 Silver Seven Road, Suite 120, Kanata,
Ontario K2V 1C3, Canada
Phone: +1-613-591-2003
Fax: +1-613-591-1006
•Brazil
Anritsu Electrônica Ltda.
Praca Amadeu Amaral, 27 - 1 Andar
01327-010-Paraiso-São Paulo-Brazil
Phone: +55-11-3283-2511
Fax: +55-11-3288-6940
•Mexico
Anritsu Company, S.A. de C.V.
Av. Ejército Nacional No. 579 Piso 9, Col. Granada
11520 México, D.F., México
Phone: +52-55-1101-2370
Fax: +52-55-5254-3147
•U.K.
Anritsu EMEA Ltd.
200 Capability Green, Luton, Bedfordshire LU1 3LU, U.K.
Phone: +44-1582-433280
Fax: +44-1582-731303
•France
Anritsu S.A.
16/18 avenue du Québec-SILIC 720
91961 COURTABOEUF CEDEX, France
Phone: +33-1-60-92-15-50
Fax: +33-1-64-46-10-65
•Germany
Anritsu GmbH
Nemetschek Haus, Konrad-Zuse-Platz 1
81829 München, Germany
Phone: +49 89 442308-0
Fax: +49 89 442308-55
•Italy
Anritsu S.p.A.
Via Elio Vittorini, 129, 00144 Roma, Italy
Phone: +39-6-509-9711
Fax: +39-6-502-2425
•Sweden
Anritsu AB
Borgafjordsgatan 13, 164 40 KISTA, Sweden
Phone: +46-853470700
Fax: +46-853470730
•Finland
Anritsu AB
Teknobulevardi 3-5, FI-01530 Vantaa, Finland
Phone: +358-20-741-8100
Fax: +358-20-741-8111
•Denmark
Anritsu A/S
Kirkebjerg Allé 90 DK-2605 Brøndby, Denmark
Phone: +45-72112200
Fax: +45-72112210
•Spain
Anritsu EMEA Ltd.
Oficina de Representación en España
Edificio Veganova
Avda de la Vega, n° 1 (edf 8, pl 1, of 8)
28108 ALCOBENDAS - Madrid, Spain
Phone: +34-914905761
Fax: +34-914905762
•United Arab Emirates
Anritsu EMEA Ltd.
Dubai Liaison Office
PO Box 500413 - Dubai Internet City
Al Thuraya Building, Tower 1, Suit 701, 7th Floor
Dubai, United Arab Emirates
Phone: +971-4-3670352
Fax: +971-4-3688460
•Singapore
Anritsu Pte Ltd.
60 Alexandra Terrace, #02-08, The Comtech (Lobby A)
Singapore 118502
Phone: +65-6282-2400
Fax: +65-6282-2533
•India
Anritsu Pte. Ltd.
India Branch Office
Unit No. S-3, Second Floor, Esteem Red Cross Bhavan,
No. 26, Race Course Road, Bangalore 560 001, India
Phone: +91-80-32944707
Fax: +91-80-22356648
•P.R. China (Hong Kong)
Anritsu Company Ltd.
Units 4&5, 28th Floor, Greenfield Tower, Concordia Plaza,
No. 1 Science Museum Road, Tsim Sha Tsui East,
Kowloon, Hong Kong
Phone: +852-2301-4980
Fax: +852-2301-3545
•P.R. China (Beijing)
Anritsu Company Ltd.
Beijing Representative Office
Room 1515, Beijing Fortune Building,
No. 5, Dong-San-Huan Bei Road,
Chao-Yang District, Beijing 10004, P.R. China
Phone: +86-10-6590-9230
Fax: +86-10-6590-9235
•Korea
Anritsu Corporation, Ltd.
8F Hyunjuk Building, 832-41, Yeoksam dong,
Kangnam-ku, Seoul, 135-080, Korea
Phone: +82-2-553-6603
Fax: +82-2-553-6604
•Australia
Anritsu Pty Ltd.
Unit 21 / 270 Ferntree Gully Road,
Notting Hill, Victoria 3168 Australia
Phone: +61-3-9558-8177
Fax: +61-3-9558-8255
•Taiwan
Anritsu Company Inc.
7F, No. 316, Sec. 1, Neihu Rd., Taipei 114, Taiwan
Phone: +886-2-8751-1816
Fax: +886-2-8751-1817

Other manuals for CMA50

1

Other Anritsu Measuring Instrument manuals

Anritsu Site Master S331P-0704 User manual

Anritsu

Anritsu Site Master S331P-0704 User manual

Anritsu VectorStar ME7848A-0272 User manual

Anritsu

Anritsu VectorStar ME7848A-0272 User manual

Anritsu MT1100A Network Master Flex User manual

Anritsu

Anritsu MT1100A Network Master Flex User manual

Anritsu Field Master Pro MS2090A User manual

Anritsu

Anritsu Field Master Pro MS2090A User manual

Anritsu Spectrum Master MS2721B User manual

Anritsu

Anritsu Spectrum Master MS2721B User manual

Anritsu Spectrum Master MS2711D Owner's manual

Anritsu

Anritsu Spectrum Master MS2711D Owner's manual

Anritsu VectorStar ME7848E Series User manual

Anritsu

Anritsu VectorStar ME7848E Series User manual

Anritsu MS2690A User manual

Anritsu

Anritsu MS2690A User manual

Anritsu ML2480B Series User manual

Anritsu

Anritsu ML2480B Series User manual

Anritsu Network Master MU909020A User manual

Anritsu

Anritsu Network Master MU909020A User manual

Anritsu Spectrum Master MS2720T User manual

Anritsu

Anritsu Spectrum Master MS2720T User manual

Anritsu MS2830A-040 User manual

Anritsu

Anritsu MS2830A-040 User manual

Anritsu Cell Master MT8212B User manual

Anritsu

Anritsu Cell Master MT8212B User manual

Anritsu MS2830A User manual

Anritsu

Anritsu MS2830A User manual

Anritsu Spectrum Master MS2711D User manual

Anritsu

Anritsu Spectrum Master MS2711D User manual

Anritsu Spectrum Master MS2721A User manual

Anritsu

Anritsu Spectrum Master MS2721A User manual

Anritsu MS2690A User manual

Anritsu

Anritsu MS2690A User manual

Anritsu Field Master Pro MS2090A User manual

Anritsu

Anritsu Field Master Pro MS2090A User manual

Anritsu VNA Master MS2024B User manual

Anritsu

Anritsu VNA Master MS2024B User manual

Anritsu 56100A User manual

Anritsu

Anritsu 56100A User manual

Anritsu MD1230A User manual

Anritsu

Anritsu MD1230A User manual

Anritsu AM-9000 Series User manual

Anritsu

Anritsu AM-9000 Series User manual

Anritsu MS2711A User manual

Anritsu

Anritsu MS2711A User manual

Anritsu BTS Master MT8221B User manual

Anritsu

Anritsu BTS Master MT8221B User manual

Popular Measuring Instrument manuals by other brands

Ponpe 8602 Operation manual

Ponpe

Ponpe 8602 Operation manual

Crowcon Gas-Pro User's and operator's manual

Crowcon

Crowcon Gas-Pro User's and operator's manual

Keithley 2611B quick start guide

Keithley

Keithley 2611B quick start guide

USA Measurements US-3011 Operation manual

USA Measurements

USA Measurements US-3011 Operation manual

Tonghui TH2689 Operation manual

Tonghui

Tonghui TH2689 Operation manual

FLUS ET-951 user manual

FLUS

FLUS ET-951 user manual

PCB Piezotronics Triaxial ICP 339A32/NC Installation and operating manual

PCB Piezotronics

PCB Piezotronics Triaxial ICP 339A32/NC Installation and operating manual

Tecsis P3922 operating manual

Tecsis

Tecsis P3922 operating manual

Circutor CVM-B100 instruction manual

Circutor

Circutor CVM-B100 instruction manual

Agilent Technologies PNA Series Installation and quick start guide

Agilent Technologies

Agilent Technologies PNA Series Installation and quick start guide

Calculated Industries AccuMaster XT 7440 user manual

Calculated Industries

Calculated Industries AccuMaster XT 7440 user manual

Milwaukee REDLITHIUM L4 3PL Operator's manual

Milwaukee

Milwaukee REDLITHIUM L4 3PL Operator's manual

Icefield Instruments ECM2 Series manual

Icefield Instruments

Icefield Instruments ECM2 Series manual

Onicon Fox Thermal FT4X quick start guide

Onicon

Onicon Fox Thermal FT4X quick start guide

Greenlee AirScout Gigacheck instruction manual

Greenlee

Greenlee AirScout Gigacheck instruction manual

Datacolor SpyderPRINT quick start guide

Datacolor

Datacolor SpyderPRINT quick start guide

Rixen M-700 user manual

Rixen

Rixen M-700 user manual

Pfeiffer Vacuum FullRange PTR 91 operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum FullRange PTR 91 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.