5
Antti-Teollisuus Oy
Scale
01-2020
The upper plate (top plate) of the scale is attached to the leg by welding or to a concrete
slab by bolts using wedge anchors. Note! The essential sensor part must not be in place between
the top and bottom plates while the plates are being attached by welding to the leg or bond plate.
We recommend placing the cable coming from the scale in a protective pipe. Connect the
free end of the cable to the connection strip behind the PAXS panel meter. Please refer to
point "meter´s basic connections" for instructions.
We recommend installing the scale terminal i.e. panel meter in the cover of the centre.
Please refer to point "installation of the meter in the panel" for instructions.
As required, shorten or extend the sensor cables to suitable length. The extension ca-
ble must absolutely be of anti-interference type, such as, e.g., well-regarded JAMAK-C
2x(2+1)x0,5. Connect the sensors parallel to each other. The cables of the two sensors go
in under the connection strip on the panel meter. When 4 sensors are being installed, we
recommend using a connection box. Join the cables coming from the sensors inside the
connection box. Then the connection box and the panel meter will be connected by only
one cable.
Solder all connections to avoid wrong reading due to poor contact.
General information of scale terminal, i.e. PAXS panel meter:
The paxs panel meter is intended for use with strain-gauge transducers, specically de-
signed for weighing purposes. The meter has free card slots for following optional output
cards:
If you want to have additional functions:
- Analog output card (4 – 20 mA ) for displaying the readouts also on the logic display
(requires that Antti-Logicontrol is used for control centre of the dryer). Setting the
parameters is instructed later in this manual.
- If you want to print out the weighing results displayed on the panel meter, you need
a RS232 serial communication card. Setting the parameters is instructed later in this
manual.
First read carefully through the following commissioning instructions and then
carry out the commissioning and programming procedure stage by stage.
STAGE1 UNPACKING
Contents:
* PAXS meter
* Installation kit (attached to the meter)
* Edge sealing for panel (separate black rubber strip)
* User manual (in English)