ANXELL AXM-800ML Series User manual

AXM-800ML / AXM-D800ML / AXM-1200ML / AXM-D1200ML Series
Electromagnetic Lock Installation Instruction (Indoor Series)
Technical Specification
Dimension & Accessories Unit:mm
AXM-800ML
Series
AXM-D800ML
Series
AXM-1200ML
Series
AXM-D1200ML
Series
Copyright All rights reserved. P-MU-AM-AXM Published on: 2021.01.21
Magnet
Armature Plate
Mounting Plate
185
14
29
45
52,5
6
265
185
267
71,5
6
40
61
16
533
71,5
6
40
185
61
16
185
61
16
29
52,5
6
530
185
14
45
185
14
45
Anti-tamper Nut
Square LED
Specification
Operating Voltage
Current Draw
Operating
Temperature
Type
ML
ML,DS
ML,TD
ML,TD,DS
DBL,ML
DBL,ML,DS
DBL,ML,TD
DBL,ML,TD,DS
Holding Force
Lock Surface
Temperature
Humidity
Finish
“The products shall not impair the intended operation of an emergency exit or panic hardware mounted on the door.”
12/24VDC
500mA/12VDC
270mA/24VDC
32° to +120.2°F ( 0° to +49°C )
800lbs AXM-800ML Series
AXM-1200ML Series1200lbs
Current temperature ± 20°C
0 to 85% Non-condensing
Magnet Surface : Galvanized
Housing : Brushed stainless
steel(US32D)
Model
AXM-800ML
AXM-800MLDS
AXM-800MLTD
AXM-800MLDS-TD
AXM-D800ML
AXM-D800MLDS
AXM-D800MLTD
AXM-D800MLDS-TD
AXM-1200ML
AXM-1200MLDS
AXM-1200MLTD
AXM-1200MLDS-TD
AXM-D1200ML
AXM-D1200MLDS
AXM-D1200MLTD
AXM-D1200MLDS-TD
800lbs 1200lbs
800lbs x2 1200lbs x2
Notes:
ML:
Bond sensor & Bi-color
square LED indicator
DS: Door status sensor
TD: Relock time delay
DBL: Double

Pre-Installation Considerations
• Use ONLY the hardware provided for mounting this product
(NOTE: Non-standard Door thickness may require different sex nut
hardware – see specific instructions for required hardware).
• Follow the installation procedure as described in this manual.
• Check door thickness. If the door is not 1 3/4” thick, a different sex
nut will be required.
• Check door header. A minimum 2 3/4” thick, flat surface is needed
to securely mount all screws for the magnet. If you do not have the
required surface, you will need filler plates and/or angle brackets to
properly mount the magnet.
Important Notes
Optional Bracket
Copyright All rights reserved. P-MU-AM-AXM Published on: 2021.01.21
Door: 1 3/4” Thick
Header: At least
2 3/4” thick, flat
The electromagnetic lock requires a
face-to-face fitting as shown in Figure
otherwise, the holding force will be
greatly decreased (direction of
hydraulic press pull must be collinear).
Remove any diode installed across the
magnetic lock for spike suppression.
The magnet is fitted with a metal oxide
varistor to prevent back EMF.
Make sure the contact area of the
electromagnetic lock and the
armature plate are clean.
Wipe the surface of magnetic lock
with anti-rust oil regularly.
Brackets installation are according to door swing direction and door frame type, e.g. narrow frame door, frameless glass door, inswing door, etc.
Regular Installation
(outswing door)
L-bracket for narrow frames U-bracket for frameless glass doors
(outswing door only)
LZ-bracket for inswing doors
EM bracket with Cover for
Inswing Door
UBK Bracket For
Glass Frame & Glass Door LZ Bracket For Inswing Door Standard Installation
For Outswing Door U Bracket For Glass Door L Bracket For Outswing Door
Warnings indicate potentially hazardous
conditions, which if not avoided or corrected,
may cause death or serious injury.
Cautions indicate potentially hazardous
conditions, which if not avoided or corrected,
may cause minor or moderate injury. Cautions
may also warn against unsafe practices.
Notices indicate a condition that may cause
equipment or property damage only.

Regular Installation
For Midi EM-locks (Model AXM-800ML), maximum thickness of door is 48 mm.
Recommendation :
For Maxi EM-locks (Model AXM-1200ML), maximum thickness of door is 46 mm.
LZ or Z bracket for inswing doors
1. Pass the power cable through the
mounting plate and Opening Type
wiring slot of the magnetic lock.
2. Combine the arc of the mounting
plate with the arc of the magnetic
lock.
3.Embed the maglocks into the mounting
plate. Fit the magnetic lock from the
bottom to the mounting plate.
4.Use the Allen wrench and fixing
screws to tighten the mounting
plate and magnetic lock.
Copyright All rights reserved. P-MU-AM-AXM Published on: 2021.01.21
Fold the mounting template 90°.
Drill the holes according to the
marks.
The rubber washer makes the
surface of the armature plate
adjustable in order to completely
fit the surface of magnetic lock.
Fix the mounting plate on the
door with mounting screws.
Connect the power and test the
unit.
Place the template to the proper
position of the door and frame.
Mark the hole positions of the
template on the door and frame.
Please install the armature plate
as illustrated here. (Dimensions
of the holes depend on the door
types illustrated below.)
Fasten the mounting plate with
the mounting screws. The position
of the mounting plate should be
adjustable.
Use the Allen wrench and fixing
bolts to tighten the electromagnetic
lock to mounting plate.
Drill a Ø8mm hole through
door, on closing side. Enlarge
to Ø12.7mm by a sexnut bolt
on the opening side.
Drill a Ø6.8mm hole
and tap on closing side
a M8x1.25 thread.
Drill a Ø8mm hole through
door on closing side. Enlarge
to Ø12.7mm by a sexnut bolt
on the opening side.
The depth is 36mm.
Find a mounting position on the door
frame for the L bracket. Make sure that
the door can still be closed.
Use the fixing bolts to tighten the
magnet on L bracket.
Assemble the Z bracket and make
sure that the Z bracket is adjustable.
Insert the guide pins into the
armature plate.

Trouble Shooting
Outdoor
Power
Protected Area
Finish
Outdoor
Power
Protected Area
Attach the armature plate and washers
to the Z bracket assembly.
Connecting Diagram
The product must be powered from , regulated, power-limited, power supply.
If power switch is not wired between DC source voltage(+) and magnet, it will take a
longer time to de-energize the magnet simulating residual magnetism.
The minimum permissible wire size to be used shall not be less than 22 AWG.
POWER SUPPLY
12/24VDC INPUT
• Required power: 12VDC/500mA ; 24VDC/270mA
• 12 or 24VDC Auto switchable
• Connect positive (+) lead from a power source to Terminal 1.
• Connect negative (-) lead from a power source to Terminal 2.
Wiring Diagram - Sample wiring and applications
*For example, if there is a fire in the building, fail-safe locks
will unlock due to loss of power, allowing personnel to
escape quickly.
KEYPAD
(Outdoor)
DIGITAL
EXIT BUTTON
(Indoor)
(Outdoor)
Key Switch
Access Control Unit
(Fail-Safe*)
Magnetic Lock
Power to Lock
(Indoor)
Door Status Sensor
Indicates the door is in and open or closed
status. Reed switch rated 0.2A/12VDC
Models:
AXM-800MLDS、AXM-800MLDS-TD
AXM-D800MLDS、AXM-D800MLDS-TD
AXM-1200MLDS、AXM-1200MLDS-TD
AXM-D1200MLDS、AXM-D1200MLDS-TD
Orange
White
Brown
: N.O.
: COM.
: N.C.
Reed Switch Contact
Sensor Icon
Visual Indications LED
UnLocked : GREEN
Locked : RED
No power : NO LED
Timer Adjustment
(1~80 seconds)
Relock time delay (Optional)
Ensures the automatic lock mode works after the
door is closed properly and it can be adjusted
from 1 to 80 seconds.
Models:
AXM-800MLTD、AXM-800MLDS-TD
AXM-D800MLTD、AXM-D800MLDS-TD
AXM-1200MLTD、AXM-1200MLDS-TD
AXM-D1200MLTD、AXM-D1200MLDS-TD
NO
NO
COM
COM
NC
NC
1
2
NO
NO
NO
NO
Bond Sensor
Output
Bond Sensor Output
Indicates the Bond and functioning status.
N.C. contact output: Open / Not bonding status.
N.O. contact output: Locked / Bonded status.
Models:
AXM-800ML、AXM-D800ML
AXM-1200ML、AXM-D1200ML
NC
NC
COM
COM
NO
NO
PB
PB
PB
PB
POWER
SUPPLY
KEYPAD
(Outdoor)
DIGITAL
EXIT BUTTON
(Indoor)
Copyright All rights reserved. P-MU-AM-AXM Published on: 2021.01.21
Close the door and connect the
power.
After the magnet attracts the armature
plate, adjust the Z bracket to fit the door.
Fasten the Z bracket to the door.
Problem
Door does
not lock
Low holding
force
Possible Cause Solution
No power
Poor contact between electromagnet
and armature plate
Low voltage or incorrect voltage
setting
Make sure the wires are connected properly
Check that the power supply is connected and working properly
Make sure the lock switch is wired correctly
Check if the armature plate is deformed?
Make sure if the rubber washer was used between magnetic lock and armature plate.
Make sure the contact surfaces of the electromagnet and armature plate are clean
and free from dust and foreign material.
Ensure the electromagnetic lock is set for the correct voltage.
Check for proper voltage at the electromagnet lock input. If low determine if the
correct wire gauge is being used to prevent excessive voltage drop.
(Indoor)
All the field wiring shall be on the secured side (or indoor).
This manual suits for next models