manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ANXELL
  6. •
  7. Door Lock
  8. •
  9. ANXELL ML-600 User manual

ANXELL ML-600 User manual

This manual suits for next models

1

Other ANXELL Door Lock manuals

ANXELL AXM-800M Series User manual

ANXELL

ANXELL AXM-800M Series User manual

ANXELL ML-605M Series User manual

ANXELL

ANXELL ML-605M Series User manual

ANXELL ML-605M-30 User manual

ANXELL

ANXELL ML-605M-30 User manual

ANXELL ML-655 Series User manual

ANXELL

ANXELL ML-655 Series User manual

ANXELL ML-705M Series User manual

ANXELL

ANXELL ML-705M Series User manual

ANXELL AXM-800ML Series User manual

ANXELL

ANXELL AXM-800ML Series User manual

Popular Door Lock manuals by other brands

Dorma MUNDUS PREMIUM US 10 Mounting instruction

Dorma

Dorma MUNDUS PREMIUM US 10 Mounting instruction

Defiant LG600BRA4BGT Instructions for installation

Defiant

Defiant LG600BRA4BGT Instructions for installation

TRU-BOLT M1740024 manual

TRU-BOLT

TRU-BOLT M1740024 manual

Opera ARCA SLIDE installation instructions

Opera

Opera ARCA SLIDE installation instructions

tell CODELOCK CL5500 Series installation instructions

tell

tell CODELOCK CL5500 Series installation instructions

ABH LR6000 installation instructions

ABH

ABH LR6000 installation instructions

Assa Abloy effeff 827A-IP Mounting instructions

Assa Abloy

Assa Abloy effeff 827A-IP Mounting instructions

Iseo MA1A installation guide

Iseo

Iseo MA1A installation guide

ID Lock 150 user manual

ID Lock

ID Lock 150 user manual

Lockly ACCESS TOUCH PRO user manual

Lockly

Lockly ACCESS TOUCH PRO user manual

iLoq G50S user guide

iLoq

iLoq G50S user guide

SDC Z7835 installation instructions

SDC

SDC Z7835 installation instructions

ilco 452 Installation

ilco

ilco 452 Installation

Samsung shs-h705 user guide

Samsung

Samsung shs-h705 user guide

TRU-BOLT 08102017 user manual

TRU-BOLT

TRU-BOLT 08102017 user manual

CDVI 500-LADJ quick start guide

CDVI

CDVI 500-LADJ quick start guide

Igloohome Deadbolt 2S Metal Grey Installer/user guide

Igloohome

Igloohome Deadbolt 2S Metal Grey Installer/user guide

eSSL FL-300 user manual

eSSL

eSSL FL-300 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Copyright All Rights Reserved. P-MU-ML-600 Published: 2020.11.25
ML-600M
275
25
24
203
43.5
83.5
3
116
250
ML-600 Electric Lock (with Mechanical Override)
Installation Instructions
Specifications Dimensions
Wiring Diagram
Lock Mode: Fail-Secure
Operating Voltage: 12~24VAC/DC
Current Draw: 500mA / 12VDC, 250mA / 24VDC
Operating Temperature: -10°C~+49°C
Humidity: 0~85% non-condensing
Preload: 300 lbs of pressure strength
Solenoid Testing: Tested up to 250,000 cycles
Latch Throw: 16mm
Relock Delay Time: 3 seconds
Optional Cylinder: EYC-72
Unti:mm
ML-600M
28
100
150
125
2
Lock Body
White
White
N.C.
COM
N.O.
Access Control
(N.O. + COM.)
Power
Supply
Black
Red
Yellow
Green
Blue Door Status Output
Circuit Description
Strike Plates
Currrent Draw
Pull in (2 secs)
Holding
Energy-saving
Door closed (3 secs)
De-energized
Time (seconds)
De-engergized
A. De-energized: Door is in locked status.(Operating in fail-secure mode)
B. Pull-in:The electric lock is energized through access control devices.
(Please refer to the wiring diagram)
C. Energy-saving: After supplying power to unlock for 2 seconds , the current
draw will drop to save energy. During this time, the electric lock remains unlocked.
D. Door closed:
After door is closed, the NIB (deadlatch) will will retract into the lock housing
and press the internal micro switch. After door keeps closing for 3 seconds, the lock
will be completely de-energized and the door will remain locked.
(Without keeping door closed for 3 seconds, the electric lock will not be de-energized
and remains unlocked.)
30 Backset
Trigger to unlock
12~24VDC/AC
5 6 78
Cut the cylinder hole.
1 2 3 4
25
275
250
150
100
28
150
Ø5.2
Ø5.2
ø5.2
310
275
30
Copyright All Rights Reserved. P-MU-ML-600 Published: 2020.11.25
Door Preparation
Using crimper or pliers and pressing the header of connector
down to even position.
Butt Splice (IDC) Connector
62mm long cylinder for doors up to 42mm thick
72mm long cylinder for doors up to 52mm thick Door Loop
(Optional)
The Door Loop is for protection
of extension wiring from damages
with high security concerns.
Attention! Please ensure that the
template is the correct way up
D
o
or
F
r
a
m
e
D
oor
L
ea
f
(Cylinder not included)
Align the center line (CL) of the lock
body template with the CL of the door
leaf. Ensure the CL of the strike plate
template matches the lock body CL as
closely as possible.
Cut out mortise holes for the lock
body and strike plate and drill
holes according to the templates.
Tighten the fixing lugs with
screws.
F
r
a
m
e
D
oor
Le
af
Alignment CL
D
oor
Le
af
D
oor
Le
af
D
oor
Le
af
D
oor
Le
af
D
oor
Le
af
D
oor
Le
af
Fr
a
m
e
Connect power cable to the lock and
secure the lock to the door leaf.
Install the cylinder hole cover. Install the cylinder. Affix the strike plate.
(backset: 30 mm)
Unti:mm
30 Backset