The ALD-40 is a hand-held leak detector that uses the in-
frared spectrum absorption principle. Compared with the
traditional leak detector, its sensor has longer life, higher
detection accuracy, easy to operate and can detect a wider
range of carbon dioxide. ALD-40 is equipped with large
LCD screen, so that the test results are more intuitive. The
exclusive design of appearance is in accordance with human
body mechanics to make it the best experience for users.
Specifications
- Sensor principle: infrared spectrum absorption
- Sensor life: 10 years
- Sensitivity: 400ppm(400ppm-4000ppm) /yr
- Alarm mode: sound and light alarm, LCD display
- Battery: built-in rechargeable lithium battery 3.7V 3000mAh
- Working time: continuous 6H
- Charging: 4 hours
- Operating environment: -10°C to 52°C/ Relative humidity (20% to
85% RH)
- Storage temperature: -20°C to 60°C (-4°F to 140°F)
- Weight:415g (14.6oz)
- Size: 201mm*86mm * 38mm (7.9"* 3.3"* 1.5 ")
- Certification: CE certification
Structure
1. Flexible probe
2. Case
3. Probe tip
4. USB Port
5. Buzzer
6. Battery
7. Peak
8. Leak
9. Sensitivity
10. Button
Key Operation
- ON/OFF key: press the button for 2 seconds
to power on/off.
- RSET key: long press the button for 3 seconds
to reset sensitivity benchmark.
- PEAK key : press the button to record the
maximum value of leakage.
- SENS key: press the button to adjust sensitivity
levels. By default sensitivity is set to medium.
- MUTE key: press the button to turn on/off the buzzer.
GAS/RSET PEAK
MUTESENS
ON/OFF
①
②
⑤
⑥
⑦
⑨
⑩
⑧
③
④
GAS/RSET
H2CO2HC R1234YF
PEAK
SEN: L
WARM UP
PEAK
MUTESENS
ON/OFF
GAS/RSET
H2CO2HC R1234YF
PEAK
SEN: L
WARM UP
PEAK
MUTESENS
ON/OFF
- Check the device has sufficient battery
level.Turn on ( on/off button ) and wait
for 30 seconds before testing.
- Adjust the sensitivity ( sens ).
GAS/RSET
H2CO2HC R1234YF
PEAK
SEN: L
WARM UP
PEAK
MUTESENS
ON/OFF
- Slowly move probe ( approx 3 inch/sec )
at a distance of 0.25 inch near suspected
leak area.
- Detection: when a leak is detected, the
screen will show the intensity of the
leak and audible tone will change to a
siren sound.