SensAlert Plus Moisture Barrier Install Instruction
• Moisture Barrier
The Plus series Moisture Barrier can be used with SensAlert Plus and SensAlert ASI Transmitters.
The plus Moisture Barrier needs to be held in place by the Sensor Shield or the Rain Shield.
The SensAlert Plus Moisture Barrier part numbers are listed below:
821-0201-01 ...........ASSY, MOISTURE BARRIER
821-0201-06 ...........6-PK MOISTURE BARRIER
Perform Installation in a safe area and with Unit power off.
1) Unscrew the Interface Ring on the Sensor Interface Assembly and remove Sensor Holder.
2) Place the Sensor Holder upside down on
a clean surface with Sensor Shield (or
Rain Shield) facing upwards.
Leave O-ring and Gaskets in place.
3) Remove the Sensor Shield (or Rain
Shield) from the Sensor Holder and
drop the Moisture Barrier into the
retainer hole with PVC Ring of the
Moisture Barrier inward – (white side out).