manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. APRVTIO
  6. •
  7. Security Sensor
  8. •
  9. APRVTIO ALD-100 User manual

APRVTIO ALD-100 User manual

ALD-100 ELECTRONIC
REFRIGERANT LEAK DETECTOR
Read this manual before using this product.
Failure to do so can result in serious injury.
WARNING
RESET
ON
OFF
ALD-100
Leak detector x 1 Flexible probe x 1
Sensing tips x 2 C batteries x 2
Aluminum case x 1 User Manual x 1
2. Automatic Circuit.
When the unit is first powered on, it will set itself to ignore the current level of
halogen in the atmosphere. This allows the unit to identify leaks by the higher
concentration of halogen present at the leak location.
- Application:R12, R11, R500, R22, R123, R124, R502, R134a, R404a, R125
refrigerants and blends such as HP62 and MP39.
- Operating temperature: 0 °C - 52 °C (30°F- 125°F)
- Maximum sensitivity: 3 g/yr., for all halogenated refrigerants
- Battery life: approx. 50 hours of normal use
- Response time: instant
- Work mode: continuous, no limitations
- Fixed probe length: 14 in
- Dimension: 9 x 2.5 x 2.5 in
- Power supply: 2C Alkaline batteries
Specifications
Packing List
Technical Specifications Video Instruction
Notices
- Do not let children handle the product, keep them away from the working
area.
- Do not submerge the product in water.
- Do not expose the product to temperatures exceeding 60°C.
- Do not leave the product in direct sunlight for long periods of time.
- Do not dismantle or attempt repairs of the product without authorization.
- Remove the batteries when not used for extended periods of time.
- Keep the sensing tip clean from dust, moisture and grease.
- If dirty, clean the tip by immersing in mild solvent such as alcohol for
several seconds then using compressed air or a towel to dry.
- Do not use solvents such as gasoline, turpentine minerals etc. to clean the
product.
- Turn the tool off before replacing the sensing tip to avoid mild electric
shock.
[email protected]https://aprvtiotech.com/ +1 713 701 1986 [email protected]https://aprvtiotech.com/ +1 713 701 1986
Tips
Alarm Indications
Battery Level Indicator
1. Adjust the sensitivity up only when a leak can be found. Adjust the
sensitivity down only when resetting the unit does not allow you to locate
the leak.
2. In areas contaminated with leaked gas, reset the unit to zero it out and
allow you to find heavier concentrations of gas. DO not move the probe
while the unit is being reset.
3. In windy areas, it may be difficult to find even a large leak. Shield potential
leak sites from wind to make finding concentrations of leaked gas easier.
4. The detector may alarm if the probe tip comes in contact with moisture or
solvents.Do not allow the tip to contact these materials.
The Electronic Refrigerant Leak Detector features 18 alarm levels from low to
high to help you find the leak.
The alarm level will increase as the leak is being approached. Alarm levels are
indicated by the last 6 LED's lighting and changing in color from Red, Green and
Orange. The LED's will light and change color from left to right, one at a time. See
alarm level chart below.
Sensitivity Indications
Seven levels of sensitivity, which increase
64 times from level 1 to level 7 allow you
to focus on the concentration appropriate
to your location.
1. Reset
Press RESET key to reset the unit to zero.
LED will turn red for 2 seconds, this confirms the reset action completed.
Green: good. Orange: low. Red: need to replace the battery.
Reset Function/ Automatic Circuit
=Battery charger indicator LED
=Red LED =Orange LED
=Green LED
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 8
Level 9
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 10
Level 11
Level 12
Level 13
Level 14
Level 15
Level 16
Level 17
Level 18
RESET
ON
OFF
ALD-100
Flexible Probe Shaft
Keyboard
Sensor Tip Protector
Sensor
Label
Front panel
Battery compartment
Main Features
Detect leaks in all A/C refrigerant systems. Respond to all halogenated
refrigerants.
7 levels of sensitives
18 alarm levels (Single color visual and audible)
Battery test function with voltage indication
Fast and easy reset function
Setup
1. Turn on the device by pressing the ON button. The display will show the
indication for 3 seconds.
2. The first light flashes green to prove that the battery is good.
3. Press the arrow up or down button to change the sensitivity. The default
level of sensitivity is 5.
4. A continuous beep tone will indicate the unit is normally functioning.
5. Start searching the leaks. When a leak is located, the beep tone will change
to a siren tone. Also, you will see the LED display the alarm. (See page 3)
6. During the use, the sensitivity can be adjusted at any time by pressing the
arrow key.
7. If a full alarm is indicated before you have found the source of the leak, you
can reset the detector to zero by pressing the reset key. This will allow you
to find progressively greater concentrations, and eventually find the source
of the leak.
[email protected]https://aprvtiotech.com/ +1 713 701 1986 [email protected]https://aprvtiotech.com/ +1 713 701 1986

Other APRVTIO Security Sensor manuals

APRVTIO ALD-300 User manual

APRVTIO

APRVTIO ALD-300 User manual

APRVTIO WJL-6000 User manual

APRVTIO

APRVTIO WJL-6000 User manual

APRVTIO ALD-200 User manual

APRVTIO

APRVTIO ALD-200 User manual

APRVTIO WJL-6000 PRO User manual

APRVTIO

APRVTIO WJL-6000 PRO User manual

Popular Security Sensor manuals by other brands

Master cool 55600-A operating instructions

Master cool

Master cool 55600-A operating instructions

Siemens FDOOT271-O Mounting

Siemens

Siemens FDOOT271-O Mounting

Mini Gadgets OmniRadar user manual

Mini Gadgets

Mini Gadgets OmniRadar user manual

Danfoss MCB 152 operating instructions

Danfoss

Danfoss MCB 152 operating instructions

Renke RS-MG41-1 user manual

Renke

Renke RS-MG41-1 user manual

PCB Piezotronics ICP W138A10/-0018 Installation and operating manual

PCB Piezotronics

PCB Piezotronics ICP W138A10/-0018 Installation and operating manual

Argus Security Taurus TW-DM-01 manual

Argus Security

Argus Security Taurus TW-DM-01 manual

EG AIR EGVOC-100 user manual

EG AIR

EG AIR EGVOC-100 user manual

turck FCS-G NAEX0 Series quick start guide

turck

turck FCS-G NAEX0 Series quick start guide

ZyAura ZGw19 operating instructions

ZyAura

ZyAura ZGw19 operating instructions

Profort luxSpot manual

Profort

Profort luxSpot manual

Technoalarm Global Space Bus quick start guide

Technoalarm

Technoalarm Global Space Bus quick start guide

SICK KTX-WB9114125A Series manual

SICK

SICK KTX-WB9114125A Series manual

Theben SPHINX 331 S KNX quick start guide

Theben

Theben SPHINX 331 S KNX quick start guide

Teledata SF3500E quick start guide

Teledata

Teledata SF3500E quick start guide

R&TTE CC-400 instruction manual

R&TTE

R&TTE CC-400 instruction manual

Pentatech MA80P v.2 owner's manual

Pentatech

Pentatech MA80P v.2 owner's manual

DANLERS WM-HBWD IP66 Series quick start guide

DANLERS

DANLERS WM-HBWD IP66 Series quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.