ALD-200 REFRIGERANT
LEAK DETECTOR
GAS/RSET
H2CO2HC R1234YF
PEAK
SEN: L
WARM UP
PEAK
MUTESENS
ON/OFF
- Do not submerge the product in water or allow water to enter the
intake of the probe.
- Do not expose the product to temperatures exceeding 60°C.
- Do not leave the product in direct sunlight for long periods of time.
- Do not dismantle or attempt repairs of the product without authorisation.
- Do not change or replace the included lithium battery.
- Do not leave for more than 6 months without charging the battery to
prevent damage.
- Do not use on objects with a charge or appliances connected to a power
source.
- Ensure the filter is present and clean before performing a test.
- Ensure there is enough power before performing a test.
- Use only the supplied charging cable.
- Avoid the inhalation of refrigerant vapor. High concentrations are harmful
and may lead to coma or death.
[email protected]https://aprvtiotech.com/ +1 713 701 1986 [email protected]https://aprvtiotech.com/ +1 713 701 1986
Technical Specifications Video Instruction
The ALD-200 Refrigerant Leak Detector is a hand-held leak
detector that uses the heated diode detection principle.
Compared with the traditional leak detector, its sensor
has a longer life, higher detection accuracy, easier to
operate and can detect a wider range of refrigerants.
The ALD-200 has an ergonomic design and a large LCD
screen for easy viewing.
Specifications
- Sensor type:heated Diode
- Sensor life: 500 hours
- Max sensitivity: 4 g /yr
- Alarm mode: Sound, light and LCD display
- Battery: Built in rechargeable lithium battery 3.7 V 3000 mAh
- Working time: Continuous 6 hours
- Charging time: 4 hours
- Charging current: 5V DC 1A
- Operating environment: -10°C to 52°C/Relative humidity (20%
to 85% RH)
- Storage temperature: -20°C to 60°C
- Weight: 415 g
- Dimension: 201x86x38 mm
- Certification: SAE_J1627, SAE_J2791, SAE_J2913, EN14624, 2012 CE
Certification
1. Flexible probe
2. Case
3. Probe tip
4. USB Port
5. Buzzer
6. Battery
7. Peak
8. Leak
9. Sensitivity
10. Button
GAS/RSET
H2CO2HC R1234YF
PEAK
SEN: L
WARM UP
PEAK
MUTESENS
ON/OFF
①
②
⑤
⑥
⑦
⑨
⑩
⑧
③
④
[email protected]https://aprvtiotech.com/ +1 713 701 1986 [email protected]https://aprvtiotech.com/ +1 713 701 1986
Structure
GAS/RSET
H2CO2HC R1234YF
PEAK
SEN: L
WARM UP
PEAK
MUTESENS
ON/OFF
GAS/RSET
H2CO2HC R1234YF
PEAK
SEN: L
WARM UP
PEAK
MUTESENS
ON/OFF
- Check the device has sufficient battery
level.Turn on ( on/off button ) and wait
for 30 seconds before testing.
- Adjust the sensitivity ( sens ).
Setup
GAS/RSET
H
2
CO
2
HC R1234YF
PEAK
SEN: L
WARMUP
PEAK
MUTESENS
ON/OFF
GAS/RSET
H2CO2HC R1234YF
PEAK
SEN: L
WARM UP
PEAK
MUTESENS
ON/OFF
- Slowly move probe ( approx 3 inch/sec )
at a distance of 0.25 inch near suspected
leak area.
- Detection: when a leak is detected, the
screen will show the intensity of the
leak and audible tone will change to a
siren sound.
Key Operation
- ON/OFF key: press the button for 2 seconds
to power on/off.
- RSET key: long press the button for 3 seconds
to reset sensitivity benchmark.
- PEAK key : press the button to record the
maximum value of leakage.
- SENS key: press the button to adjust sensitivity
levels. By default sensitivity is set to medium.
- MUTE key: press the button to turn on/off the buzzer.
GAS/RSET PEAK
MUTESENS
ON/OFF

Other APRVTIO Security Sensor manuals

APRVTIO WJL-6000 PRO User manual

APRVTIO

APRVTIO WJL-6000 PRO User manual

APRVTIO ALD-300 User manual

APRVTIO

APRVTIO ALD-300 User manual

APRVTIO WJL-6000 User manual

APRVTIO

APRVTIO WJL-6000 User manual

APRVTIO ALD-100 User manual

APRVTIO

APRVTIO ALD-100 User manual

Popular Security Sensor manuals by other brands

Waters 2489 Operator's guide

Waters

Waters 2489 Operator's guide

Forney UV-4 quick start guide

Forney

Forney UV-4 quick start guide

Optex AX-100TFR Series installation instructions

Optex

Optex AX-100TFR Series installation instructions

Dalsa Shad-o-Scan 3001 user manual

Dalsa

Dalsa Shad-o-Scan 3001 user manual

CAME SMA operating instructions

CAME

CAME SMA operating instructions

Linear DXS-54 installation instructions

Linear

Linear DXS-54 installation instructions

Conrad 75 19 01 operating instructions

Conrad

Conrad 75 19 01 operating instructions

KRAUSE ProTec Instructions for assembly

KRAUSE

KRAUSE ProTec Instructions for assembly

Sicame CATU Detex CC-265 manual

Sicame

Sicame CATU Detex CC-265 manual

YATO YT-73138 Original instruction

YATO

YATO YT-73138 Original instruction

Evikon PluraSens E2638-O2 user manual

Evikon

Evikon PluraSens E2638-O2 user manual

KPS KPS-DT100 instruction manual

KPS

KPS KPS-DT100 instruction manual

TOPP RDC/12V Installation and use instructions and warnings

TOPP

TOPP RDC/12V Installation and use instructions and warnings

KJB PRO-10G user manual

KJB

KJB PRO-10G user manual

Solutions UWT NivoGuide 8200 Technical Information/Instruction manual

Solutions

Solutions UWT NivoGuide 8200 Technical Information/Instruction manual

Doberman SE-0134A quick guide

Doberman

Doberman SE-0134A quick guide

bolid ECHO-5 instruction manual

bolid

bolid ECHO-5 instruction manual

Agilent Technologies 1260 Infinity user manual

Agilent Technologies

Agilent Technologies 1260 Infinity user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.