Step 3. Connect the output connectors of the RSD-S-PLC in series to the string, the string
open-air DC voltage is within the range of (0.6 ~ 1v) X #RSD-S-PLCs. (This range may vary
due to dierent on-site environment.)
NOTE: Do not connect homerun to inverter before finishing all strings connections and tests.
√
×
×
2021/10/08 Rev2.7 | Quick Installation Guide2
Product information is subject to change without notice. (Please download manuals at www.APsmartglobal.com).
APsmart
600 Ericksen Ave NE, Suite 200 Seattle, WA 98110 | +1-737-218-8486
+1-866-374-8538 | APsmartglobal.com | support@APsmartglobal.com
Bending Radius of the cable >50mm
√
NOTE: Please use the same type of DC connector as the RSD in the system. The RSD damage caused by using
dierent type of DC connector will not be covered by the warranty.