APT Inverex XP Pro 750 User manual

Inverex Inverter
V. 1.0
Quick Guide

Table of Contents
1. Introduction ...................................................................................................................................................1
2. Important Safety Warning (SAVE THESE INSTRUCTIONS)......................................................................1
3. Product Overview .........................................................................................................................................2
4. Installation .....................................................................................................................................................2
5. Operation .......................................................................................................................................................3
6. Trouble Shooting ..........................................................................................................................................8
7. Specifications ...............................................................................................................................................8

1
1. Introduction
INVEREX Inverter is a compact inverter designed to power your home appliances or precious electronics. Its
compact size features easy installation and high movability. Besides, its high surge capability also can handle
motor-type loads such as vacuums, small freezers, or drills.
Compared to traditional inverters in the market, this inverter provides two operation modes: UPS mode and
Inverter mode. At UPS mode, the inverter becomes an UPS which can provide pure power source to PC-related
equipment or sensitive devices. At Inverter mode, the inverter can provide continuous power to general home
appliances.
2. Important Safety Warning (SAVE THESE INSTRUCTIONS)
Before using the inverter, please read all instructions and cautionary markings on the unit, this
manual and the batteries.
General Precaution-
CAUTION! The unit is designed for indoor use. Do not expose this unit to rain, snow or liquids of any type.
CAUTION! To reduce risk of injury, only use qualified batteries from qualified distributors or manufacturers.
Any unqualified batteries may cause damage and injury. Do NOT use old or overdue batteries. Please check the
battery type and date code before installation to avoid damage and injury.
WARNING! It's very important for system safety and efficient operation to use appropriate external battery
cable. To reduce risk of injury, external battery cables should be UL certified and rated for 75°C or higher. And
do not use copper cables less than 10AWG. Below is the external battery cable reference according to system
requirements.
CAUTION! Do not disassemble the inverter. Contact with the qualified service center when service or repair is
required.
WARNING! Provide ventilation to outdoors from the battery compartment. The battery enclosure should be
designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment.
CAUTION! Use insulated tools to reduce the chance of short-circuit when installing or working with the inverter,
the batteries, or other equipments attached to this unit.
CAUTION! For battery installation and maintenance, read the battery manufacturer's installation and
maintenance instructions prior to operating.
Personnel Precaution -
CAUTION! Careful to reduce the risk or dropping a metal tool on the batteries. It could spark or short circuit the
batteries and could cause an explosion.
CAUTION! Remove personal metal items such as rings, bracelets, necklaces, and watches when working with
batteries. Batteries can produce a short circuit current high enough to make metal melt, and could cause severe
burns.
CAUTION! Avoid touching eyes while working near batteries.
CAUTION! Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.
CAUTION! NEVER smoke or allow a spark or flame in vicinity of a battery.
CAUTION! If a remote or automatic generator start system is used, disable the automatic starting circuit or
disconnect the generator to prevent accident during servicing.
Conventions used:
WARNING! Warnings identify conditions or practices that could result in personal injury;
CAUTION! Caution identify conditions or practices that could result in damaged to the unit or other
equipment connected.

2
3. Product Overview
4. Installation
NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged.
Mounting the unit
The unit ONLY can be mounted vertically to a wall surface.
Please follow below steps:
1. Turn off the unit before mounting.
2. Select an appropriate mounting location. Use a horizontal line and the
length of the line must be 80 mm and mark the two ends on the wall.
(see right chart)
3. Drill two marks by screws.
4. Mount the unit by positioning the key-hole slots over the mounting screws.
Connect to Utility and Charge
Plug in the AC input cord to the wall outlet. The unit will automatically charge the
connected external battery even though the unit is off.
Connect External Battery
Step 1- Take away the cover of external battery terminal.
Step 2- Following battery polarity guide printed near the battery terminal!
Place the external battery cable ring terminal over the battery terminal.
RED cable to the positive terminal (+);
BLACK cable to the negative terminal (-).
WARNING! Please use the appropriate battery cable. Please refer to Important Safety Warnings Section
for the details.
Step 3- Tight the battery cables with the M5 nuts. Do NOT place anything between the flat part of battery
terminal and the battery cable ring terminal, or overheating may occur. (See Fig. 1)
Fig. 1
Step 4- Install a DC Breaker in a positive battery line. The rating of the DC Breaker must be according to the
inverter's battery current (75 Amp). Keep the DC breaker off. (see Fig. 2)
Step 5- Connect battery cables to the external batteries. Note: For the user operation safety, we strongly
recommend that you should use tapes to isolate the battery terminals before you start to operate the unit.
1) Single battery connection (Refer to Fig. 2): When using a single battery, its voltage must be equal to
the Nominal DC Voltage of the unit (see below Table 1).
Power switch
Status indicators (please see the
Operation section for the details)
LCD display
Output receptacles
AC input
Input circuit breaker
External battery connectors

3
Fig. 2
2) Multiple batteries in series connection(Refer to Fig. 3): All batteries must be equal in voltage and
amp hour capacity. The sum of their voltages must be equal to the nominal DC Voltage of the unit.
Fig 3
3) Multiple batteries in parallel connection(Refer to Fig. 4): Each battery's voltage must be equal to the
Nominal DC Voltage of the unit.
Fig 4
Step 6- Make sure to connect the polarity of battery side and the unit correctly.
Positive pole (Red) of battery to the positive terminal (+) of the unit.
Negative pole (Black) of battery to the negative terminal (-) of the unit.
Step 7- Put the covers back to the external battery terminals.
Step 8- Take the DC breaker on.
5. Operation
Power On/Off
Once the inverter has been properly installed, press the power switch to turn on the unit. The unit will work
automatically in line mode or inverter mode according to input utility power's status. When press the power
switch again, the unit will be turned off.
LED Indicators & Audible Alarms
There are three indicators (Green/Green/Red) in the front panel of the unit.
LED Indicator
Messages
Green
Solid On
Output is available in bypass mode
Flashing
Output is powered by battery in inverter mode
Green
Solid On
Battery is fully charged
Flashing
Battery is charging now
Red
Solid On
Fault mode
Flashing
battery low or overload warning
Buzzer Audible Alarm
Messages
Inverter Mode
(Low-battery Voltage)
Buzzing every 1 seconds
110% overload warning
Buzzing every 0.5 second
Overcharge
Buzzing continuously
Fault mode
Buzzing continuously for 0.5 hour, unit shutdown (BAT-MODE)
Buzzing continuously(Line mode)
Table 1
Model
Nominal Battery DC Voltage
750/ 1200
12 VDC
2400
24 VDC
This manual suits for next models
2
Table of contents
Other APT Inverter manuals
Popular Inverter manuals by other brands

BARRON
BARRON EXITRONIX Tucson Micro Series installation instructions

Baumer
Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

electroil
electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

Silicon Solar
Silicon Solar TPS555-1230 instruction manual

Mission Critical
Mission Critical Xantrex Freedom SW-RVC owner's guide

HP
HP 3312A Operating and service manual