ARC InstaTemp User manual

Non-Touch ermometer
User Manual
ARC Devices Ltd.
Copyright ARC Devices Ltd. 2015

Welcome to your new state of the art ARC InstaTemp™
digital infrared non touch thermometer! e ARC
InstaTemp™ is a digital non-touch thermometer that
measures and displays human body temperature. is
device is intended for use by responsible adults at
home.
To ensure the best results with your ARC InstaTemp™
thermometer, please be sure to read the following
operational and procedural manual carefully. If you
give this device to another adult, it is vital that you also
pass on this user manual.
e ARC InstaTemp™ is a sophisticated technologically
advanced electronic medical device that has been
carefully engineered to quickly and accurately measure
human body temperature without requiring any contact
with the human body. Do not use this device for any
other purpose. Only use ARC InstaTemp™ in ambient
temperatures ranging from 50-104°F (10-40°C). e
thermometer and person must remain in a place
with no change in room temperature and away from
ventilation sources and heat sources for at least 20
minutes before measuring temperature.

NOTE: PLEASE READ
PRECAUTIONS BEFORE
OPERATING
ARC InstaTemp™
Manual
GETTING TO KNOW
e ARC InstaTemp™

Infrared Sensor
Backlit LCD
Display Screen
Remove protective
label prior to
commencing
operation.
Temperature
Range Indicator
Light
Activation Button
Internal
non- removable,
non-replaceable,
batteries are
included
ARC InstaTemp™
GETTING TO KNOW
e ARC InstaTemp™

Quick and accurate body
temperature measurement
LCD screen with backlight for
ease of use in the dark
Temperature shown in either
Fahrenheit (° F) or Celsius (° C)
e temperature reading will
be displayed on screen for
4 seconds
Turns o automatically when
not in use
Fast temperature readings
that meet the ASTM standard
LED display temperature range
indicator system:
Green, Orange, Red.
Low battery indicator
Features
1
2
3
4
5
6
7
8
GETTING TO KNOW
e ARC InstaTemp™

ARC InstaTemp™ is set to Fahrenheit by default.
To change to Celsius, follow these simple steps:
Press and release the activation button to get a reading.
Once the reading appears on screen in Fahrenheit,
press and release the activation button again —the
reading will automatically change to Celsius. Repeat to
change back.
OPERATION:
CHANGING ºF TO ºC

Remove protective label prior to
operation
Move hair away from the path of
the sensor.
Wipe perspiration from the
forehead, if apparent
Ensure that the person has been
in the room for 20 minutes.
Do not measure the person’s
temperature immediately aer
he/she has been exposed to really
cold or hot climates, or has drunk
a hot or cold liquid as it may
temporarily change the surface
temperature of the skin. In these
instances, wait 20 minutes before
taking a temperature reading
Do not touch the lens of the
sensor. It is the most delicate
part of the ARC InstaTemp™
Before attempting to take a
temperature reading:
1
1
2 3 4 5 6 7 8
OPERATION:
TAKING A TEMPERATURE
1

Point the thermometer at the person as
shown below. Ensure the device is 0.5-1.25
ins (1-3 cm) from the forehead, above the
eyebrows and between the eyes.
ARC InstaTemp™ must be held steady, perpendicular
to and pointing directly at the center of the forehead
at the area above the eyebrows and between the eyes
when taking a temperature.
Hold the ARC InstaTemp™ in position, and press and
release the activation button once, simply point and
click. Hold the thermometer in position until the
display is illuminated and a temperature reading is
displayed on the screen.
1
2
3 4 5 6 7 8
OPERATION:
TAKING A TEMPERATURE
0.5” - 1.25”
(1-3cm)
Point and Click

e temperature reading will be displayed
for 4 seconds.
1 2
3
4 5 6 7 8
1 2 3
4
5 6 7 8
e temperature range indicator will be
green, orange or red depending on the
temperature measurement detected.
Should you wish to take a second reading, wait for 5
seconds and repeat.
Do not hold the activation button between
measurements.
Temperature Range Indicator System
OPERATION:
TAKING A TEMPERATURE

UNDERSTANDING THE TEMPERATURE
RANGE INDICATOR SYSTEM
Sleep Mode
C
<32º
>32.0ºC – ≤34.9ºC >38.1ºC – ≤42.8ºC >42.8ºC
>35.0ºC – ≤35.9ºC >37.3ºC – ≤38.0ºC
>36.0ºC – ≤37.2ºC
<89.5ºF
>89.5ºF – ≤94.9ºF >100.5ºF – ≤109.1ºF >109.1ºF
>94.9ºF – ≤96.7ºF >99.0ºF – ≤100.5ºF
>96.7ºF – ≤99.0ºF
e thermometer measured a temperature
<89.5°F (<32⁰C). e temperature range indicator
is red and LO is displayed.

UNDERSTANDING THE TEMPERATURE
RANGE INDICATOR SYSTEM
Sleep Mode
C
<32º
>32.0ºC – ≤34.9ºC
>38.1ºC – ≤42.8ºC >42.8ºC
>35.0ºC – ≤35.9ºC >37.3ºC – ≤38.0ºC
>36.0ºC – ≤37.2ºC
<89.5ºF
>89.5ºF – ≤94.9ºF
>100.5ºF – ≤109.1ºF >109.1ºF
>94.9ºF – ≤96.7ºF >99.0ºF – ≤100.5ºF
>96.7ºF – ≤99.0ºF
e thermometer measured a temperature
≥89.5ºF – ≤94.9ºF (≥32.0ºC - ≤34.9ºC). e
temperature range indicator is red and a temperature
reading is displayed.

UNDERSTANDING THE TEMPERATURE
RANGE INDICATOR SYSTEM
Sleep Mode
C
<32º >32.0ºC – ≤34.9ºC >38.1ºC – ≤42.8ºC >42.8ºC
>35.0ºC – ≤35.9ºC
>37.3ºC – ≤38.0ºC
>36.0ºC – ≤37.2ºC
<89.5ºF >89.5ºF – ≤94.9ºF >100.5ºF – ≤109.1ºF >109.1ºF
>94.9ºF – ≤96.7ºF
>99.0ºF – ≤100.5ºF
>96.7ºF – ≤99.0ºF
e thermometer measured a temperature
≥95.0ºF – ≤96.7ºF (≥35.0ºC - ≤35.9ºC). e
temperature range indicator is orange and a
temperature reading is displayed.

UNDERSTANDING THE TEMPERATURE
RANGE INDICATOR SYSTEM
Sleep Mode
C
<32º >32.0ºC – ≤34.9ºC >38.1ºC – ≤42.8ºC >42.8ºC
>35.0ºC – ≤35.9ºC >37.3ºC – ≤38.0ºC
>36.0ºC – ≤37.2ºC
<89.5ºF >89.5ºF – ≤94.9ºF >100.5ºF – ≤109.1ºF >109.1ºF
>94.9ºF – ≤96.7ºF >99.0ºF – ≤100.5ºF
>96.7ºF – ≤99.0ºF
e thermometer measured a temperature
≥96.8ºF – ≤99.0ºF (≥36.0ºC - ≤37.2ºC). e
temperature range indicator is green and a
temperature reading is displayed.

UNDERSTANDING THE TEMPERATURE
RANGE INDICATOR SYSTEM
Sleep Mode
C
<32º >32.0ºC – ≤34.9ºC >38.1ºC – ≤42.8ºC >42.8ºC
>35.0ºC – ≤35.9ºC
>37.3ºC – ≤38.0ºC
>36.0ºC – ≤37.2ºC
<89.5ºF >89.5ºF – ≤94.9ºF >100.5ºF – ≤109.1ºF >109.1ºF
>94.9ºF – ≤96.7ºF
>99.0ºF – ≤100.5ºF
>96.7ºF – ≤99.0ºF
e thermometer measured a temperature
≥99.1ºF – ≤100.5ºF (≥37.3ºC - ≤38.0ºC). e
temperature range indicator is orange and a
temperature reading is displayed.

UNDERSTANDING THE TEMPERATURE
RANGE INDICATOR SYSTEM
Sleep Mode
C
<32º >32.0ºC – ≤34.9ºC
>38.1ºC – ≤42.8ºC
>42.8ºC
>35.0ºC – ≤35.9ºC >37.3ºC – ≤38.0ºC
>36.0ºC – ≤37.2ºC
<89.5ºF >89.5ºF – ≤94.9ºF
>100.5ºF – ≤109.1ºF
>109.1ºF
>94.9ºF – ≤96.7ºF >99.0ºF – ≤100.5ºF
>96.7ºF – ≤99.0ºF
e thermometer measured a temperature
≥100.6ºF – ≤109.1ºF (≥38.1ºC - ≤42.8ºC). e
temperature range indicator is red and a temperature
reading is displayed.

UNDERSTANDING THE TEMPERATURE
RANGE INDICATOR SYSTEM
Sleep Mode
C
<32º >32.0ºC – ≤34.9ºC >38.1ºC – ≤42.8ºC
>42.8ºC
>35.0ºC – ≤35.9ºC >37.3ºC – ≤38.0ºC
>36.0ºC – ≤37.2ºC
<89.5ºF >89.5ºF – ≤94.9ºF >100.5ºF – ≤109.1ºF
>109.1ºF
>94.9ºF – ≤96.7ºF >99.0ºF – ≤100.5ºF
>96.7ºF – ≤99.0ºF
e thermometer measured a temperature
>109.1ºF (>42.8ºC). e temperature range indicator is
red and HI is displayed.

UNDERSTANDING THE TEMPERATURE
RANGE INDICATOR SYSTEM
<32ºC
≥32.0ºC – ≤34.9ºC ≥38.1ºC – ≤42.8ºC >42.8ºC
Sleep Mode
≥35.0ºC – ≤35.9ºC ≥37.3ºC – ≤38.0ºC
≥36.0ºC – ≤37.2ºC
<89.5ºF ≥89.5ºF – ≤94.9ºF ≥100.5ºF – ≤109.1ºF >109.1ºF
≥94.9ºF – ≤96.7ºF ≥99.0ºF – ≤100.5ºF
≥96.7ºF – ≤99.0ºF
Aer 4 seconds the backlight, LCD display and
temperature range indicator turn o and the
thermometer powers down.

Pull the hood of the case back.
Remove the device by holding
it on its sides, and slide it into
the case, such that the LCD
screen is slightly visible.
Do not touch the sensor.
Cover with the hood and store
in a dry place.
Pull the hood of the neoprene
case back.
Grab the ARC InstaTemp™
on its sides and pull out of
the case.
To insert the ARC InstaTemp™ into the
neoprene carrying case.
To remove the ARC InstaTemp™ from the
neoprene carrying case.
GETTING TO KNOW
Carrying and Storage (If accessory is included)
1
1
2
3
2

GETTING TO KNOW
Wall Mount (If accessory is included)
e wall mount can be attached to any smooth
vertical surface using its adhesive pad on the
rear of the wall mount. Because it is magnetic,
the wall mount can also be attached to any metal
surface. e internal magnet also keeps the ARC
InstaTemp™ gently attached to the wall mount.

TROUBLESHOOTING
Er message
Red temperature range
indicator light
Low battery symbol
Red temperature range
indicator light
No function, no display
when activation button is
pressed
3 dashes (---)
Red temperature range
indicator light
is indicates an invalid reading. is is due
to incorrect usage, such as trying to measure a
temperature above or below the thermometer’s
operating range or also due to a indeterminate
reading. Repeat the temperature measurement
as described in the section titled ‘TAKING A
TEMPERATURE’.
Other manuals for InstaTemp
1
Table of contents
Other ARC Thermometer manuals
Popular Thermometer manuals by other brands

Omega Engineering
Omega Engineering HH801A operating instructions

Extech Instruments
Extech Instruments IR100 user manual

GREISINGER
GREISINGER GMH 3210 user manual

Cole Parmer
Cole Parmer TRACEABLE LOLLIPOP 6419 instructions

Lanaform
Lanaform FILOO Instructions for use

Extech Instruments
Extech Instruments 445715 instructions