GENERAL OPERATING AND SAFETY INSTRUCTIONS
This appliance is a portable air conditioner designed for domestic
use.
Only use this air conditioner as described in this manual.
Ensure that the required voltage and frequency (220-240 V/50 Hz)
match the available power source.
This appliance can be used by children aged from 8 years and
above and people with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children
without supervision.
Ensure that the electricity system is able to deliver the operating
current required by the air conditioner, in addition to that normally
absorbed by other appliances (electrical appliances, lighting system,
etc.). Please refer to the maximum power input data shown on the
air conditioner's data plate.
Connection to the electricity grid must take place in accordance with
current installation standards.
Ensure that the automatic switches and system protection valves
are able to withstand a start-up current of 6A (normally for less than
1 second).
The power socket must always include an efficient earth connection.
Make sure that the plug is properly inserted into the socket. Do not
use multiple adapters. Do not touch the plug with wet hands. Make
sure that the plug is clean.
Do not use the plug for starting/stopping the air conditioner: use the
ON/OFF button on the remote control or control panel instead.
Do not install the air conditioner in rooms potentially subject to water
sprays (e.g. laundries).

17
V 10/16
This air conditioner can be used by children of 8 years or older and
by persons with reduced physical, sensory and mental abilities, or
lacking the necessary experience and knowledge, provided they are
supervised or instructed on its use by a person responsible for their
safety, so that they are fully aware of the attendant risks.
Before moving or cleaning the appliance, ensure that it is unplugged
from the socket.
Do not move the air conditioner while it is operating; first turn the
appliance off, then check and remove any condensate which may
have formed.
To turn the appliance off, set the remote control to OFF and remove
the plug from the socket. Pull on the plug only. Do not pull the cord.
Do not use the appliance if the cord or plug are damaged.
Contact a service centre to replace a damaged power cord, so as to
avoid any safety risks.
PRECAUTION!
Do not insert any objects into the air conditioner: this is very
dangerous as the fan turns at high speed.
Ensure that air circulates freely around the unit. Do not cover
the air intake and delivery grilles with drapes or any other
means.
WARNING!
The air conditioner must be positioned at least 50 cm from the wall
or any other obstacles, on a flat and stable surface so as to avoid
water leaks.
The air conditioner is fitted with a system to protect the
compressor from overload. This means that the compressor
only starts 3 minutes after its previous stoppage.
Please wait at least 3 minutes before starting the unit. This
helps prevent the compressor from being damaged.

18
V 10/16
WARNING!
In the event of an anomaly, switch the appliance off and unplug
from the socket. Do not dismantle or attempt to repair or modify
the product. In the event of a malfunction, contact the service
centre directly.
WARNING!
Do not expose the air conditioner to direct sunlight, as the
colour of the materials may change; moreover, the appliance
may overheat causing the protection mechanism to intervene
and switch the appliance off.
Do not use insecticides, oils, detergents or spray paints near
the appliance; do not use aggressive chemical detergents to
clean the casing: this may damage the finish and colour.
Close all open windows to maximise air conditioning
efficiency.
The manufacturer will not be held liable if safety and accident
prevention rules are not observed.

19
V 10/16
DESCRIPTION OF THE APPLIANCE
FRONT VIEW
REAR VIEW
Min/max operating limits (internal temperature)
Cooling: 16 °C DB / 35 °C DB
Heating (Softy plus): 5 °C DB / 27 °C DB
Dehumidification: 16 °C DB / 35 °C DB
Cooling mode room temperature adjustment range: 16 °C DB / 32 °C DB
1) CONTROL PANEL AND BUTTONS FOR
OPERATION WITHOUT REMOTE CONTROL
2) FIN AND AIR FLOW OUTLET
3) SIGNAL RECEIVER
4) FRONT
5) HANDLES
6) AIR INTAKE
7) HANDLES
8) DRAINAGE HOLE (DEHUMIDIFICATION)
9) AIR INTAKE
10) DRAINAGE HOLE (ONLY FOR MODELS WITH
HEAT PUMP)
11) POWER CORD OUTLET
12) DRAINAGE HOLE (COOLING)
13) UPPER FILTER (BEHIND GRILLE)
14) UPPER AIR INTAKE
15) LOWER FILTER (BEHIND GRILLE)
16) LOWER AIR INTAKE
17) WHEELS
18) REMOTE CONTROL
9) A
1
(18)

20
V 10/16
APPLIANCE START-UP
Open the packaging and pull out the box. Remove the product and the other elements supplied (illustrated in the box
below).
LCD remote control.
Type-AAA
batteries for
remote
control.
Round fitting (1) for positioning between
the air discharge outlet and the flexible
pipe.
Flexible pipe.
End fitting for window (2).
Window unit kit with plug.
Round fitting for window
unit, for positioning
between the end of the
tube and the window unit
itself.
Drainage tube (continuous
drainage).
Position the product vertically on a flat and stable surface, as close as possible to a window and at least 50 cm from
walls or other nearby obstacles.
USE WITH END FITTING FOR WINDOW
1. Connect the round fitting (1) to the flexible pipe,
extend the tube until it reaches the outside and
connect to the rear of the air conditioner.
2. Slide the flat fitting downwards into the grooves (A)
and secure it with the hook on top (B).

21
V 10/16
3. Connect the end part of the flexible pipe to the round
fitting for the window (2).
The drainage tube can be compressed to minimum 45
mm and extended to maximum 1500 mm. It is
advisable to keep the tube compressed to the
minimum.
4. Open the windows and lock one of the two leaves
with the handle.
Place the end fitting against the fixed leaf of the
window and
draw the other leaf against it.
5. Avoid tight bends and folds in the flexible pipe.
USE WITH WINDOW UNIT KIT
1. Make a hole having a diameter of roughly 133
mm on the glass window.
2. Insert the window unit into the window.
3. Insert the round fitting into the retractable flexible
pipe and insert the latter with its round fitting into
the window unit without the plug.
4. Insert the round fitting onto the flexible pipe.
5. Insert the flexible pipe thus mounted into the rear of the
air conditioner.
If the air conditioner is not used for prolonged periods, disconnect the pipe and plug the window unit.
Connect the power cord to a suitable electric socket (220–240 V). Insert the supplied batteries into the remote control
and make sure the poles match. Select the desired operating mode from the remote control.

22
V 10/16
HOW TO USE THE APPLIANCE
This appliance can be used for SOFTY cooling, heating (only model SOFTY PLUS), dehumidification and ventilation.
When switching between modes, the fan continues to turn but the compressor stops: the compressor will re-start after 3
minutes. This delay protects the compressor from potential damage.
THE DISCHARGE TUBE MUST BE CONNECTED to the appliance AT ALL TIMES: the only exception is when the
appliance is used in dehumidification mode only, in which case the appliance should be left to discharge directly
into the room for maximum efficiency (see the “Dehumidification Mode” paragraph).
Clean the air filters under the easily removable rear grille regularly to keep the air conditioner working efficiently.
OPERATING MODES
1. COOLING MODE (COOL)
The “Cool” LED on the control panel will turn on.
The temperature can be adjusted to between 16 °C and 32 °C.
In this mode, each time the ON/OFF button is pressed the unit switches off, the appliance saves the temperature
setting and retains this setting when it is switched on again.
In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set.
For more silent operation, run the fan at low speed.
2. HEATING MODE (HEAT) (Softy plus)
The “Heat” LED on the control panel will turn on.
The temperature can be adjusted to between 16 °C and 32 °C.
In this mode, each time the ON/OFF button is pressed the unit switches off, the appliance saves the temperature
setting and retains this setting when it is switched on again.
In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set.
For more silent operation, run the fan at low speed.
3. DEHUMIDIFICATION MODE (DRY)
Press the MODE button to select the dehumidification mode.
The temperature is controlled by the electronic board and cannot be adjusted.
In this mode, each time the ON/OFF button is pressed the unit switches off, the appliance saves the settings and
retains them when it is switched on again.
The fan speed is set to low and cannot be adjusted.
Cooling, Heating, Ventilation
Dehumidification

23
V 10/16
NOTE
The air conditioner does not cool the room when operating as a dehumidifier.
When the appliance is used as a dehumidifier, the flexible pipe must not be connected.
For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly into
the environment.
The dehumidification mode is recommended during autumn and winter.
If used during summer, it is best to leave the flexible pipe attached so that the hot air is discharged towards
the outside rather than into the room.
During dehumidification, continuous drainage should be implemented (see the next chapter, “HOW TO ELIMINATE
CONDENSATE”).
4. VENTILATION MODE (FAN ONLY)
Press the MODE button until the Fan icon appears.
In this mode, the fan speed can be adjusted.
The temperature cannot be adjusted.
HOW TO ELIMINATE CONDENSATE
Cooling & Heating (Softy plus)
This appliance automatically vaporises condensate in the cooling and heating mode.
Ensure that when the unit is operating in cooling and heating mode, the rubber caps
closing the drainage holes on the rear of the appliance are properly positioned.
When the air conditioner operates in cooling and heating mode, there is no need for
continuous condensate drainage; only in specific weather conditions with very high air
humidity levels may water deposit inside the unit. When the internal container is full,
the display visualises message “P1” and the appliance stops functioning.
To empty the container, switch the air conditioner off and unplug it. Remove the cap
form the rear drainage hole and direct it over a normal drain.
Ensure that the tube is not twisted or bent. The tube must slope downwards. Re-close
the drainage hole with the cap and resume use of the air conditioner.
Dehumidification
WARNING!
When using the air conditioner in dehumidification mode, it is advisable to always
arrange for continuous drainage, so as to maximise dehumidification efficiency.
Connect one end of the PVC pipe provided to the rear discharge hole and place the
other end above a drain.

24
V 10/16
REMOTE CONTROL OPERATION
Insert the batteries into the remote control and make sure the poles
match.
Only use type-AAA 1.5 V batteries.
Remove the batteries if the remote control is not used for a month
or longer.
Do not attempt to recharge the batteries. Replace all batteries at the
same time.
Do not throw the batteries into fire: they may explode.
FOR OPTIMAL REMOTE CONTROL OPERATION, POINT THE TRANSMITTER HEAD TOWARDS THE
RECEIVER ON THE AIR CONDITIONER.
1
2
3
4
5
6
7
8
9
1. ON/OFF BUTTON
2. TEMPERATURE AND TIMER BUTTONS
3. MODE BUTTON
4. SCREEN BUTTON (LCD ON/OFF)
5. SLEEP BUTTON
6. SPEED BUTTON
7. SWING BUTTON
8. FEELING BUTTON
9. TIMER BUTTON
INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN DIRECTIVE
2006/66/EC
Please replace batteries when flat: at the end of their useful life, batteries must not be disposed of with unsorted waste. They must
be taken to designated recycling centres or returned to a retailer providing this service. Separate disposal of batteries prevents
potential negative effects on the environment and human health due to inadequate disposal, and also allows for recovering and
recycling their constituent materials, resulting in significant savings in terms of energy and resources. The separate disposal
obligation is underlined by the crossed-out dustbin symbol appearing on the battery. Illegal disposal of the product by the user is
subject to administrative penalties as per current regulations.
Transmitter
head
Operation
display

25
V 10/16
(1)ON/OFF BUTTON
Press the ON/OFF button to switch the unit on or off.
When switched on, the appliance will start operating in the last mode set (save function).
(2) TEMPERATURE AND TIMER BUTTON
Increase temperature :
1) Allows for adjusting the desired temperature in cooling mode.
2) Whenever the button is pressed, the set temperature increases by 1 °C.
Decrease temperature :
1) Allows for adjusting the desired temperature in cooling mode.
2) Whenever the button is pressed, the set temperature decreases by 1 °C.
The same button is used for setting the TIMER.
(3)MODE SELECTION BUTTON (MODE)
Press this button to select the various operating modes, according to the following sequence:
Cooling (Cool) →Dehumidification (Dry) →Heating (Heat) (enabled only on model Softy plus) →Ventilation (Fan Only) →
Auto
(4) SCREEN BUTTON
Used for switching the LCD on or off.
(5)SLEEP BUTTON
Press this button to activate the Sleep function, which automatically adjusts the temperature to changes in body and
room temperature during the night, for optimal sleeping comfort and minimal consumption.
In cooling mode, the temperature increases by 1 °C in an hour then by 2 °C in two hours, and remains in this setting for
the whole period. The Sleep function is not available in the ventilation, dehumidification and auto modes. When Sleep
function is set, control panel display switches off , to not disturb sleeping in the night.
In heating mode, the temperature decreases by 1 °C in an hour then by 2 °C in two hours, and remains in this setting
for the whole period. The Sleep function is not available in the ventilation, dehumidification and auto modes. When
Sleep function is set, control panel display switches off , to not disturb sleeping in the night.
After 7 hours of operation in SLEEP mode, the air conditioner switches off automatically.
Note: press MODE and ON/OFF together to cancel the SLEEP function setting on the remote control.
(6) FAN SPEED BUTTON (SPEED)
Press this button when the appliance is on to adjust the fan speed to Low, Medium, High or AUTO.
The fan speed cannot be adjusted in DRY mode and is set to low speed.
(7) SWING BUTTON
Press this button to let the horizontal fins swing automatically; after setting the desired fin angle, press the button again
to lock the angle.
(8) FEELING BUTTON
Activates the sensor on the remote control: the word ROOM will appear on the remote control.
The LCD will show the room temperature; when the function is cancelled, it will show the set temperature. This function
is disabled in the FAN mode.
(9) TIMER BUTTON
Select the function from the remote control: the relevant LED will light up.
Press the timer button again on the remote control, without deselecting the LED on the unit.
Next, select the time remaining to on or off.
1)Timer-on (automatic switch-on)
When the appliance is off, this button is used to set a delay after which the unit will switch itself on.
Remote control: Press TIMER. The T-ON and H icons will light up on the remote control. Press the + and -
buttons within 5 seconds to set the delay. The T-ON icon will remain on to indicate that the TIMER is running.
Unit: Press TIMER. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm.

26
V 10/16
2)Timer-off (automatic switch-off)
When the appliance is running in COOL mode, this function is used to set the delay after which the unit switches off.
Remote control: Press TIMER. The T-OFF and H icons light up. Press the + and - buttons within 5 seconds to set
the delay. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm. The T-OFF icon will remain
on to indicate that the TIMER is running.
Unit: Press TIMER. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm.
Cancelling the timer: If a TIMER is set, press TIMER to display the set timer. Press TIMER again to cancel the set TIMER.
ERROR MESSAGES ON THE DISPLAY
If any error messages appear, like E1 or E3, switch the air conditioner off and take it to the service centre.
It the display shows P1, this means that the internal tank is full and condensate must be drained before restarting the
appliance.
CARE AND MAINTENANCE
WARNING!
Before carrying out any cleaning or maintenance operations, unplug the appliance.
1. Cleaning the air filters
The air filters must be checked at least once every two weeks
of use. Operating the appliance with dirty or clogged filters will
decrease the air conditioner's efficiency and may cause
serious problems.
To remove filter 1: release the grille by pressing the filter tab,
then slide the filter away from the tabs by pulling it gently
towards the side.
To remove filter 2: use a screwdriver to loosen the two
screws holding the filter then pull the filter cover towards the
right.
Use a vacuum cleaner to remove the dust from the filters.
Should this not suffice, wash the filter with lukewarm water
and some neutral detergent (if necessary), then rinse it
thoroughly in cold water and leave it to dry in air before
putting it back in place. Once the filter has been replaced,
close the grille and resume use of the air conditioner.

27
V 10/16
2. Cleaning the casing.
Use a damp and soft cloth to clean the outer surface of the
appliance.
Do not use excessively hot water, solvents, petrol or other
aggressive chemical compounds, talcum powder or brushes:
these may damage the surface or colour of the casing.
Remove any stains using lukewarm water with a little neutral
detergent.
Do not pour water onto the air conditioner to clean it, as this may
damage its internal components or cause a short-circuit.
3. Storage.
When you do not expect to use the air conditioner for a long time,
clean the filters before storing it away.
Keep the appliance in a vertical position at all times. Do not place
heavy objects on top of the air conditioner. It is advisable
to protect the appliance with a plastic sheet.
4. Transport.
Where possible, transport the air conditioner in a vertical
position.
Should this not be possible, rest it on its right-hand side;
when the appliance reaches its final destination, place it
immediately in the vertical position and wait at least 4
hours before operating it in cooling mode.
5. For complete safety, regularly check the condition of the power cord; should it be damaged as a result of wear,
contact the Service Centre to replace it.
TIPS FOR MAXIMISING COMFORT AND MINIMISING CONSUMPTION
CHECK that:
the unit intake and delivery grilles are always free;
the air filters are always clean; a dirty filter will decrease the passage of air and reduce the unit's performance;
all doors and windows are closed, so as to avoid infiltration of unconditioned air;
the flexible pipe is correctly positioned, without tight bends or curves;
the room temperature is above 18 ºC for the cooling mode, and above 10 ºC for the dehumidification mode.
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R410A, a fluorinated greenhouse gas with global warming potential (GWP) = 2087.50.
– Kg. 0.40 = 0.835 Tonn CO2equiv. Do not release R410A into the atmosphere.
INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN
DIRECTIVE 2012/19/EU
This appliance may not be scrapped with domestic waste at the end of its life cycle. We call your attention to
the crucial role played by the consumer in the re-use, recycling and other forms of recovery of such waste.
The appliance must be scrapped by a sorted waste disposal centre or by returning it to the retailer (no charge is
levied for this service), when you purchase a new equivalent appliance.
Sorted disposal of electric and electronic equipment prevents the negative effects on the environment and
human health resulting from improper scrapping, and also allows the materials from which it is made to be
recovered and recycled, with significant savings in terms of energy and resources.
The sorted disposal requirement is indicated by the crossed waste bin label affixed to the appliance.
www.argoclima.com
This manual suits for next models
1
Table of contents
Other Argo Air Conditioner manuals

Argo
Argo Euro-Line AWR508CL Operating manual

Argo
Argo DSAV92R5TAA Manual

Argo
Argo POLIFEMO BILLY User manual

Argo
Argo AWR222CLE - AER222SC Operating manual

Argo
Argo SDG18MHWP User manual

Argo
Argo CHARM DUBBEL 9000 UI User manual

Argo
Argo AS71CL Manual

Argo
Argo MILO PLUS User manual

Argo
Argo Extreme 9 User manual

Argo
Argo AER608SH Manual
Popular Air Conditioner manuals by other brands

Haier
Haier SYJS-0308 Service manual

Bosch
Bosch Climate 5000 Series installation manual

Carrier
Carrier PAR524 owner's manual

Kogan
Kogan SMARTERHOME KAWFSAC26UA user guide

Mitsubishi Electric
Mitsubishi Electric City Multi PUHY-HP144TSHMU-A Service handbook

Midea
Midea Forest MOAA31-12CN1-NB8 Technical manual