SDWP-001
Electronic touch panel cabinet lock
User manual
●
DIGIT PANEL:
Touch digits panel to activate the system.
●
Default code:
For 8-digit management: 12345678
For 6-digit user: 123456.
●
Security alarm:
If entering wrong code 3 times, digit panel will flash with alarm sound
“beep beep beep” for 30 seconds. You are not able to enter any digit at this
moment until alarm off.
SET UP AUTO / MANUAL CLOSE MODE
The lock is set to auto-close mode initially.
To switch the auto / manual mode, press the
button A at back of the lock.
●
Auto-close mode (“ Beep beep” sound):
The plunger will come out after 8 second.
●
Manual-close mode (“Beep” sound):
An user has to enter 6-digit user code, then the plunger will come out.
Modify code:
●
Change user’s code
After open the lock with user code Press “set” Enter “new 6 digit code” Press “OK”
Plunger will come out if code Press “OK” button again Enter “6-digit” code again
•changes successfully
●
Change management’s code
After open the lock with management’s code Press “set” Enter “new 8 digit code”
Press “OK” button again Enter “8-digit” code again Press “ OK” button
Plunger will come out if code changes successfully
**User code will default to 123456 after using management code to unlock
Lock and unlock (Under manual-close mode ):
●
To unlock
Enter 6 digit code Press “OK” button The plunger goes in to “Unlock”
●
To lock
Enter 6 digit code Press “OK” button The plunger comes out to “Lock”
**When entering wrong code, press “SET” to erase and re-enter user code
Lock and unlock (Under auto-close mode ):
Using user 6-digit code
●
To unlock and lock
Touch digit panel to activate system Press 2 random digits Press user 6-digit code
•Press “OK” button again to lock Press “OK” button to unlock
After 6 seconds, the plunger will come out automatically
Using management 8-digit code
●
To unlock and lock
Touch digit panel to activate system Press 2 random digits Press admin 8-digit code
•Press “OK” button again to lock Press “OK” button to unlock
After 6 seconds, the plunger will come out automatically
**When enter admin 8-digit code to open lock, the user’s 6-digit code will default to 123456
Reset
Press button “B” to reset system. Management code will
default to 12345678 and user code will default to
123456
Low voltage alarm:
If voltage drops to 3.6V, digit panel will flash with alarm sound when you touch the
panel. It means to remind you that voltage is low and please change new batteries.
Put your finger on the panel for 3 seconds to exit alarm, and then enter your code to
unlock.
Emergency external power:
When voltage is below 3.6V, which is out of working voltage. You can put new 1.5V x 3 pcs in the
battery case and insert to the socket under the front case.
VOLTAGE
4.5V
WORKING
TEMPERATURE
0°C ~40°C
STATIC
CURRENT
≤45uA
WORKING
HUMIDITY
20% ~80%
Warning
…Voltage input cannot be over than 6V
…Risk of suffocation from small parts and packing materials!
·Screws, small parts and packing materials can be deadly playthings for children.
·Do not leave the packing materials and the contents lying around carelessly, and keep away from
children and babies.
Installation:

Popular Door Lock manuals by other brands

Iseo Zero1 Thesis 2.0 Standard instruction manual

Iseo

Iseo Zero1 Thesis 2.0 Standard instruction manual

okidokeys Smart Lock installation manual

okidokeys

okidokeys Smart Lock installation manual

Assa Abloy 7003 user manual

Assa Abloy

Assa Abloy 7003 user manual

Yale Code Handle Fitting and operating instructions

Yale

Yale Code Handle Fitting and operating instructions

Assa Abloy Corbin Russwin SE LP10 9600 Series installation instructions

Assa Abloy

Assa Abloy Corbin Russwin SE LP10 9600 Series installation instructions

Samsung SHP-DS510 user guide

Samsung

Samsung SHP-DS510 user guide

Salto XS4 Original+ E i 450 RO Series installation guide

Salto

Salto XS4 Original+ E i 450 RO Series installation guide

Nedap uPASS Access installation guide

Nedap

Nedap uPASS Access installation guide

SDC 1190A Series manual

SDC

SDC 1190A Series manual

ILCO Unican DT-509275 AMM installation instructions

ILCO Unican

ILCO Unican DT-509275 AMM installation instructions

Assa Abloy Lockwood 530 DX Series Service manual

Assa Abloy

Assa Abloy Lockwood 530 DX Series Service manual

ZKTeco ZL600 installation guide

ZKTeco

ZKTeco ZL600 installation guide

BURG-WACHTER secuENTRY pro 7116 Duo Assembly and user's manual

BURG-WACHTER

BURG-WACHTER secuENTRY pro 7116 Duo Assembly and user's manual

Assa Abloy Sargent PE8600 Series installation instructions

Assa Abloy

Assa Abloy Sargent PE8600 Series installation instructions

masunt 520 M operating instructions

masunt

masunt 520 M operating instructions

AST SureLock SLGDL-7 Operation and installation manual

AST

AST SureLock SLGDL-7 Operation and installation manual

SDC FS23M Series installation instructions

SDC

SDC FS23M Series installation instructions

Transmitter Solutions DOLCSAW10KH Quick reference programming guide

Transmitter Solutions

Transmitter Solutions DOLCSAW10KH Quick reference programming guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.