Installation Instructions
8800 Series
Mortise Lock
80-8800-0016-000 12/20
5 Installation, continued
4Install Levers
Figure 8 
Figure 9 
Figure 10 
1. Insert outside mounting plate through 
door and lock body, and hold. (Figure 8)
2. Align and fasten inside mounting plate 
securely with two (2) #8-32 x 1-1/4" 
screws.
3. Install roses on inside and outside 
adapter plates.
5Install Indicator Mounting Plate
6Install Indicator Assembly
1. Screw indicator mounting plate to door with four 
(4) #6 x 3/8" sheet metal screws. (Figure 9)
2. If indicators are being used on both sides of door, 
repeat step 5.1 for opposite side.
1. Verify lock is in unlocked state (turn outside 
lever to confirm).
2. Verify indicator is in vacant/unlocked position.
3. Assemble indicator assembly onto mounting 
plate. (Figure 10)
4. Secure indicator assembly to door with two (2) 
machine screws.
• Use #832 x 5/8" screw for top 
• Use #832 x 3/8" screw for bottom
5. If indicators are being used on both sides of 
door, repeat steps 6.1 through 6.3 for opposite 
side.
NOTE: Torx security screws recommended.
Outside 
of door
Inside of door
Inside of door Outside of door
Inside lever
Rose RH door 
shown
Set Screw
#832 x 11/4" 
Screws
Inside MountingPlate
Outside Mounting Plate
Mounting 
Plate
#6 x 3/8" Screws
Indicator 
Assembly
#832 x 5/8" 
Screw
4. If included, press rose adapter into rose and 
mounting plate assemblies.
5. Unscrew inside spindle 1/2 turn and align 
ramp in the horizontal position.
6. Slide plastic bushing onto outside lever and 
spindle and insert through the lockbody.
7. Slide plastic bushing onto inside lever and 
attach to spindle. Then tighten inside lever 
set screw.
Rose
Plastic Bushing
Rose Adapter Rose Adapter
Plastic Bushing
Outside Lever and Spindle
#832 x 3/8" 
Screw