Artesyn MVME721X RTM Quick start guide

MVME721X RTM
Installation and Use
P/N: 6806800M42D
April 2015

© Copyright 2015 Artesyn Embedded Technologies, Inc.
All rights reserved.
Trademarks
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of
Artesyn Embedded Technologies, Inc.©2015 Artesyn Embedded Technologies, Inc. All other product or service names are the
property of their respective owners.
Intel®is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.
Java™and all other Java-based marks are trademarks or registered trademarks of Oracle America, Inc. in the U.S. and other countries.
Microsoft®, Windows®and Windows Me®are registered trademarks of Microsoft Corporation; and Windows XP™is a trademark of
Microsoft Corporation.
PICMG®, CompactPCI®, AdvancedTCA™and the PICMG, CompactPCI and AdvancedTCA logos are registered trademarks of the PCI
Industrial Computer Manufacturers Group.
UNIX®is a registered trademark of The Open Group in the United States and other countries.
Notice
While reasonable efforts have been made to assure the accuracy of this document, Artesyn assumes no liability resulting from any
omissions in this document, or from the use of the information obtained therein. Artesyn reserves the right to revise this document
and to make changes from time to time in the content hereof without obligation of Artesyn to notify any person of such revision or
changes.
Electronic versions of this material may be read online, downloaded for personal use, or referenced in another document as a URL to
an Artesyn website. The text itself may not be published commercially in print or electronic form, edited, translated, or otherwise
altered without the permission of Artesyn.
It is possible that this publication may contain reference to or information about Artesyn products (machines and programs),
programming, or services that are not available in your country. Such references or information must not be construed to mean that
Artesyn intends to announce such Artesyn products, programming, or services in your country.
Limited and Restricted Rights Legend
If the documentation contained herein is supplied, directly or indirectly, to the U.S. Government, the following notice shall apply
unless otherwise agreed to in writing by Artesyn.
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (b)(3) of the Rights in
Technical Data clause at DFARS 252.227-7013 (Nov. 1995) and of the Rights in Noncommercial Computer Software and
Documentation clause at DFARS 252.227-7014 (Jun. 1995).
Contact Address
Artesyn Embedded Technologies Artesyn Embedded Technologies
Marketing Communications Lilienthalstr. 17-19
2900 S. Diablo Way, Suite 190 85579 Neubiberg/Munich
Tempe, Arizona 85282 Germany

Contents
MVME721X RTM Installation and Use (6806800M42D) 3
About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Safety Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
1.2 Rear Transition Module Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
1.3 Standard Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1.4 Mechanical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1.5 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2 Hardware Preparation and Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.1 Unpacking and Inspecting the RTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.2 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.2.1 Environmental Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.3 RTM Installation and Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
2.3.1 PMC I/O Module (PIM) Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
2.3.2 Installing the RTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.3.3 Removing the RTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3 Controls, LEDs, and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
3.2 SEEPROM Address Switch, S1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
3.3 Rear Panel Connectors and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
3.3.1 Rear Panel Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
3.3.1.1 J1 (Serial) and J2 (Ethernet) Pinout Connectors . . . . . . . . . . . . . . . . . . . . . . . . . 42
3.3.1.2 PMC Input/Output Module (PIM) Connectors (J10/J14) . . . . . . . . . . . . . . . . . . 44
3.3.1.3 VME Backplane P2 Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
3.3.2 LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
3.4 FRU Serial EEPROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Contents

MVME721X RTM Installation and Use (6806800M42D)
Contents
4
Contents
Contents
A Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
A.1 Artesyn Embedded Technologies - Embedded Computing Documentation . . . . . . . . . . . . . . . . 51

List of Tables
MVME721X RTM Installation and Use (6806800M42D) 5
Table 1-1 Standard Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 1-2 Mechanical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 1-3 Available RTM Variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 2-1 Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 3-1 SEEPROM Address Switch Assignments (RTM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 3-2 Switch Settings and Device Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 3-3 Transition Module Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Table 3-4 J1 and J2 Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Table 3-5 J10 Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Table 3-6 J14 Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Table 3-7 VME Backplane P2 Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Table 3-8 Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Table A-1 Artesyn Embedded Technologies - Embedded Computing Publications . . . . . . . . . . . . . . 51

MVME721X RTM Installation and Use (6806800M42D)
6
List of Tables

List of Figures
MVME721X RTM Installation and Use (6806800M42D) 7
Figure 1-1 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 1-2 Component Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 2-1 Installing the PIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 2-2 IEEE Handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 2-3 IEEE Handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 2-4 IEEE Handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 2-5 IEEE Handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 2-6 Scanbe Handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 3-1 S1 Switch Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Figure 3-2 Rear Panel Connectors and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

MVME721X RTM Installation and Use (6806800M42D)
8
List of Figures

MVME721X RTM Installation and Use (6806800M42D) 9
About this Manual
Overview of Contents
This manual is intended for users who install and configure MVME721X RTM. It is assumed that
the user is familiar with the standard cabling procedures, installation and removal procedures
of MVME721X RTM. The user must be a professional engineer in the server device field, who has
been trained and is able to identify danger levels when operating the device.
This manual is divided into the following chapters and appendices.
Introduction describes the main features of the RTM.
Hardware Preparation and Installation details the installation prerequisites and the
installation itself.
Controls, LEDs, and Connectors describes external interfaces such as connectors and LEDs.
Related Documentation lists further Artesyn user manuals for other products that use the
RTM, such as MVME7100, MVME2500, iVME7210, and MVME4100.
Abbreviations
This document uses the following abbreviations:
Abbreviation Definition
CPLD Complex Programmable Logic Device
DDR3 Double Data Rate 3
DMI Direct Media Interface
DUART Dual UART
EEPROM Erasable Programmable Read-Only Memory
FCC Federal Communications Commission
IEEE Institute of Electrical and Electronics Engineers
MCP Multi-Chip Package
MRAM Magnetoresistive Random Access Memory
PCI Peripheral Component Interconnect
PCI-E PCI Express
PIM PCI Mezzanine Card Input/Output Module

MVME721X RTM Installation and Use (6806800M42D)
About this Manual
10
About this Manual
Conventions
The following table describes the conventions used throughout this manual.
PLD Programmable Logic Device
PMC PCI Mezzanine Card (IEEE P1386.1)
RTC Real-Time Clock
RTM Rear Transition Module
SATA Serial AT Attachment
UART Universal Asynchronous Receiver-Transmitter
VITA VMEbus International Trade Association
VME Versa Module Eurocard
XMC PCI Express Mezzanine Card
Abbreviation Definition
Notation Description
0x00000000 Typical notation for hexadecimal numbers (digits are
0 through F), for example used for addresses and
offsets
0b0000 Same for binary numbers (digits are 0 and 1)
bold Used to emphasize a word
Screen Usedforon-screen output and coderelatedelements
or commands in body text
Courier + Bold Used to characterize user input and to separate it
from system output
Reference Used for references and for table and figure
descriptions
File > Exit Notation for selecting a submenu
<text> Notation for variables and keys
[text] Notation for software buttons to click on the screen
and parameter description

About this Manual
MVME721X RTM Installation and Use (6806800M42D) 11
... Repeated item for example node 1, node 2, ..., node
12
.
.
.
Omission of information from example/command
that is not necessary at the time being
.. Ranges, for example: 0..4 means one of the integers
0,1,2,3, and 4 (used in registers)
| Logical OR
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury
Indicates a hazardous situation which, if not avoided,
may result in minor or moderate injury
Indicates a property damage message
No danger encountered. Pay attention to important
information
Notation Description

MVME721X RTM Installation and Use (6806800M42D)
About this Manual
12
About this Manual
Summary of Changes
This manual has been revised and replaces all prior editions.
Part Number Publication Date Description
6806800M42A May 2011 GA Version
6806800M42B June 2011 Added tables and information on pin
assignments for J1 (Serial) and J2 (Ethernet) Pinout
Connectors, PMC Input/Output Module (PIM)
Connectors (J10/J14), and VME Backplane P2
Connector underChapter3,Rear Panel Connectors,
on page 42
6806800M42C July 2011 Added Chapter 2, Removing the RTM, on page 37.
Updated drawings of IEEE and Scanbe handles
and updated RTM installation and removal
procedures in Chapter 2, RTM Installation and
Removal, on page 28. Updated information on
Table "Environmental Conditions" on page 27.
6806800M42D April 2015 Re-branded to Artesyn template.

MVME721X RTM Installation and Use (6806800M42D) 13
Safety Notes
This section provides warnings that precede potentially dangerous procedures throughout
this manual. Instructions contained in the warnings must be followed during all phases of
operation, service, and repair of this equipment. You should also employ all other safety
precautions necessary for the operation of the equipment in your operating environment.
Failure to comply with these precautions or with specific warnings elsewhere in this manual
could result in personal injury or damage to the equipment.
Artesyn intends to provide all necessary information to install and handle the product in this
manual. Because of the complexity of this product and its various uses, we do not guarantee
that the given information is complete. If you need additional information, ask your Artesyn
representative.
The product has been designed to meet the standard industrial safety requirements. It must
not be used except in its specific area of office telecommunication industry and industrial
control.
Only personnel trained by Artesyn or persons qualified in electronics or electrical engineering
are authorized to install, remove or maintain the product.
The information given in this manual is meant to complete the knowledge of a specialist and
must not be used as replacement for qualified personnel. Keep away from live circuits inside
the equipment. Operating personnel must not remove equipment covers. Only factory
authorized service personnel or other qualified service personnel may remove equipment
covers for internal subassembly or component replacement or any internal adjustment.
Do not install substitute parts or perform any unauthorized modification of the equipment or
the warranty may be voided. Contact your local Artesyn representative for service and repair
to make sure that all safety features are maintained.

MVME721X RTM Installation and Use (6806800M42D)
Safety Notes
14
Electrical Interference
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense. Changes or
modifications not expressly approved by Artesyn could void the user's authority to operate the
equipment. Board products are tested in a representative system to show compliance with the
above mentioned requirements. A proper installation in a compliant system will maintain the
required performance. Use only shielded cables when connecting peripherals to assure that
appropriate radio frequency emissions compliance is maintained.
Installation
Damage of the RTM and Additional Devices and Modules
Incorrect installation or removal of additional devices or modules may damage the RTM or the
additional devices or modules.
Before installing or removing additional devices or modules, read the respective
documentation.
Damage of Circuits
Electrostatic discharge and incorrect installation and removal of the RTM can damage circuits
or shorten its life.
Before touching the RTM or electronic components, make sure that you are working in an ESD-
safe environment.
Damage of the RTM
Incorrect installation of the RTM can cause damage of the RTM.
Only use handles when installing/removing the RTM to avoid damage/deformation to the face
plate and/or PCB.

Safety Notes
MVME721X RTM Installation and Use (6806800M42D) 15
Damage to RTM/Backplane or System Components
Bent pins or loose components can cause damage to the RTM, the backplane, or other system
components.
Therefore, carefully inspect the RTM and the backplane for both pin and component integrity
before installation.
Artesyn and our suppliers take significant steps to ensure there are no bent pins on the
backplane or connector damage to the blades/RTMs prior to leaving the factory. Bent pins
caused by improper installation or by inserting blades with damaged connectors could void
the Artesyn warranty for the backplane or blades.
Operation
Damage of the RTM
High humidity and condensation on the RTM surface causes short circuits.
Do not operate the RTM outside the specified environmental limits. Make sure the RTM is
completely dry and there is no moisture on any surface before applying power.
Cabling and Connectors
Environment
Always dispose of used blades, system components and RTMs according to your country’s
legislation and manufacturer’s instructions.

MVME721X RTM Installation and Use (6806800M42D)
Safety Notes
16

MVME721X RTM Installation and Use (6806800M42D) 17
Sicherheitshinweise
Dieses Kapitel enthält Hinweise, die potentiell gefährlichen Prozeduren innerhalb dieses
Handbuchs vorrangestellt sind. Beachten Sie unbedingt in allen Phasen des Betriebs, der
Wartung und der Reparatur des Systems die Anweisungen, die diesen Hinweisen enthalten
sind. Sie sollten außerdem alle anderen Vorsichtsmaßnahmen treffen, die für den Betrieb des
Produktes innerhalb Ihrer Betriebsumgebung notwendig sind. Wenn Sie diese
Vorsichtsmaßnahmen oder Sicherheitshinweise, die an anderer Stelle diese Handbuchs
enthalten sind, nicht beachten, kann das Verletzungen oder Schäden am Produkt zur Folge
haben.
Artesyn ist darauf bedacht, alle notwendigen Informationen zum Einbau und zum Umgang mit
dem Produkt in diesem Handbuch bereit zu stellen. Da es sich jedoch um ein komplexes
Produkt mit vielfältigen Einsatzmöglichkeiten handelt, können wir die Vollständigkeit der im
Handbuch enthaltenen Informationen nicht garantieren. Falls Sie weitere Informationen
benötigen sollten, wenden Sie sich bitte an die für Sie zuständige Geschäftsstelle von Artesyn.
Das System erfüllt die für die Industrie geforderten Sicherheitsvorschriften und darf
ausschließlich für Anwendungen in der Telekommunikationsindustrie und im Zusammenhang
mit Industriesteuerungen verwendet werden.
Einbau, Wartung und Betrieb dürfen nur von durch Artesyn ausgebildetem oder im Bereich
Elektronik oder Elektrotechnik qualifiziertem Personal durchgeführt werden. Die in diesem
Handbuch enthaltenen Informationen dienen ausschließlich dazu, das Wissen von
Fachpersonal zu ergänzen, können dieses jedoch nicht ersetzen.
Halten Sie sich von stromführenden Leitungen innerhalb des Produktes fern. Entfernen Sie auf
keinen Fall Abdeckungen am Produkt. Nur werksseitig zugelassenes Wartungspersonal oder
anderweitig qualifiziertes Wartungspersonal darf Abdeckungen entfernen, um Komponenten
zu ersetzen oder andere Anpassungen vorzunehmen.
Installieren Sie keine Ersatzteile oder führen Sie keine unerlaubten Veränderungen am Produkt
durch, sonst verfällt die Garantie. Wenden Sie sich für Wartung oder Reparatur bitte an die für
Sie zuständige Geschäftsstelle von Artesyn. So stellen Sie sicher, dass alle
sicherheitsrelevanten Aspekte beachtet werden.

MVME721X RTM Installation and Use (6806800M42D)
Sicherheitshinweise
18
EMV
Das Produkt wurde in einem Artesyn Standard system getestet. Es erfüllt die für digitale Geräte
der Klasse A gültigen Grenzwerte in einem solchen System gemäß den FCC-Richtlinien
Abschnitt 15 bzw. EN 55022 Klasse A. Diese Grenzwerte sollen einen angemessenen Schutz
vor Störstrahlung beim Betrieb des Produktes in Gewerbe- sowie Industriegebieten
gewährleisten.
Das Produkt arbeitet im Hochfrequenzbereich und erzeugt Störstrahlung. Bei
unsachgemäßem Einbau und anderem als in diesem Handbuch beschriebenen Betrieb können
Störungen im Hochfrequenzbereich auftreten.
Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich
Funkstörungen verursachen. In diesem Fall kann vom Betreiber verlangt werden,
angemessene Maßnahmen durchzuführen.
Installation
Beschädigung des RTMs und von Zusatzmodulen
Fehlerhafte Installation von Zusatzmodulen, kann zur Beschädigung des RTMs und der
Zusatzmodule führen.
Lesen Sie daher vor der Installation von Zusatzmodulen die zugehörige Dokumentation.
Beschädigung von Schaltkreisen
Elektrostatische Entladung und unsachgemäßer Ein- und Ausbau von Blades/RTMs kann
Schaltkreise beschädigen oder ihre Lebensdauer verkürzen. Bevor Sie Blades/RTMs oder
elektronische Komponenten berühren, vergewissern Sie sich, dass
Sie in einem ESD-geschützten Bereich arbeiten.
Beschädigung des RTMs
Fehlerhafte Installation des RTMs kann zu einer Beschädigung des RTMs führen.
Verwenden Sie die Handles, um das RTM zu installieren/deinstallieren. Auf diese Weise
vermeiden Sie, dass das Face Plate oder die Platine deformiert oder zerstört wird.

Sicherheitshinweise
MVME721X RTM Installation and Use (6806800M42D) 19
Beschädigung des RTMs, der Backplane oder von System Komponenten
Verbogene Pins oder lose Komponenten können zu einer Beschädigung des RTMs, der
Backplane oder von Systemkomponenten führen.
Überprüfen Sie daher das RTM sowie die Backplane vor der Installation sorgältig und stellen Sie
sicher, dass sich beide in einwandfreien Zustand befinden und keine Pins verbogen sind.
Artesyn und unsere Zulieferer unternehmen größte Anstrengungen um sicherzustellen, dass
sich Pins und Stecker von Blades/RTMs vor dem Verlassen der Produktionsstätte in
einwandfreiem Zustand befinden. Verbogene Pins, verursacht durch fehlerhafte Installation
oder durch Installation von Blades/RTMs mit beschädigten Steckern kann die durch Artesyn
gewährte Garantie für Blades und Backplanes erlöschen lassen.
Betrieb
Beschädigung des Blades
Die RJ-45-Stecker an der Frontblende sind für Anschlüsse vom Typ Twisted-Pair Ethernet (TPE)
oder E1/T1/J1 vorgesehen. Der Anschluss eines E1/T1/J1-Interfaces an einen Ethernet-Stecker
kann zur Zerstörung des Blades führen.
Stellen Sie daher sicher, dass TPE-Stecker an Ihrem Arbeitsplatz eindeutig als
Netzwerkstecker gekennzeichnet sind.
Stellen Sie sicher, dass die Länge eines Kabels, welches an den RJ-45-Stecker
angeschlossen ist, 100 m nicht überschreitet.
Stellen Sie sicher, dass der TPE-Stecker ausschließlich mit einem Safety-Extra-Low-
Voltage-Stromkreis (SELV) verbunden ist.
Wenden Sie sich bei Fragen an ihren Systemadministrator
Beschädigung am Telefon
Die CH2und CH3 Stecker sind mit einem durchgestrichenem Telefonhörer markiert. Wenn Sie
an diese Stecker ein Telefon anschließen, kann Ihr Telefon beschädigt werden. Benutzen Sie für
diese Stecker ausschließlich das CABLE-8001-CLK-3/10 Kabel.

MVME721X RTM Installation and Use (6806800M42D)
Sicherheitshinweise
20
Umweltschutz
Entsorgen Sie alte Batterien und/oder Blades/Systemkomponenten/RTMs stets gemäß der in
Ihrem Land gültigen Gesetzgebung.
Table of contents
Other Artesyn Control Unit manuals
Popular Control Unit manuals by other brands

Pickering
Pickering 40-670 user manual

Kutai electronics
Kutai electronics ATS-PLC Operation manual

Comelit
Comelit 1259C Technical manual

Goetze
Goetze 4000 Assembly instructions

Valve Concepts
Valve Concepts 1049 Secure-Gard Installation, operation and maintenance manual

Barthelme
Barthelme CHROMOFLEX manual

Dtrovision
Dtrovision Pure Link DVI-DOC-F owner's manual

Omron
Omron NX-SL series Instruction & reference manual

VIA Technologies
VIA Technologies WMP-G10 user manual

INOXPA
INOXPA NL Installation, service and maintenance instructions

Aulisa
Aulisa ECG Instructions for use

Hubbell
Hubbell GAI-TRONICS HUBBCOM GRC600SS quick start guide