■HOW TO OPERATE
◆H-75
①Loosen Knob and pull out Wire. (Do not pull out Wire any more if you find “red mark” on Wire.)
②Insert Wire to the pipe slowly and when Head reaches the blockage or Head cannot be inserted due to an
acute bend of the pipe, tighten Knob to hold Wire.
③Holding Grip by right hand, rotate Handle clockwise to clean the pipe.
④In case of heavy blockage, repeat to move Wire for and backward with rotating Handle clockwise and counter-
clockwise.
⑤When finished cleaning the pipe, pull back Wire to Wire Case with washing and spraying Wire with
anticorrosive oil.
(Optional Accessory : Rowonal R72142)
◆H-150
①Loosen Knob, pull up Chuck Handle to release Wire and pull out Wire. (Do not pull out Wire any more if you
find “red mark” on wire.)
②Insert Wire to the pipe slowly and when Head reaches the blockage or Head cannot be inserted due to an
acute bend of the pipe, push down Chuck Handle to hold Wire. Tighten Knob also when Wire cannot be held
by Chuck Handle.
③In case of heavy blockage, repeat to move Wire for and backward with rotating Handle clockwise and counter-
clockwise.
④When finished cleaning the pipe, pull back Wire to Wire Case with washing and spraying Wire with
anticorrosive oil.
(Optional Accessory : Rowonal R72142)
■HOW TO OPEN WIRE CASE
Wire Case can be opened when Wire is twisted in Wire Case or to clean the inside of Wire Case.
◆How to open
Loosen 4 pcs. of Stop Bolt A (Fig.1) and loosen 4 pcs. of Stop Bolt fixing Wire Case.
(Wire Case for H-75 is fixed with 3 pcs. of Stop Bolt.)
■HOW TO FIX HANDLE (H-150)
Insert Handle and tighten Stop Bolt with the attached
Allen Wrench.
Allen Wrench can be used to open Wire Case.
INSTRUCTION MANUAL
DRAIN CLEANER H-75 DRAIN CLEANER H-150
①Wire Case ①Wire Case
②Knob ②Knob
③Wire ③Head
④Grip ④Chuck Handle
⑤Handle ⑤Handle
CLASSIFICATION OF CAUTIONS
WARNING : Indicates a potentially hazardous situation which, if not avoided, could result in death or serious
injury.
CAUTION : Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate
injury or damage to the machine.
①
②
③ ④ ⑤
①
② ③
④
⑤
Fig.1
Stop Bolt
Handle
A
IM801

WARNING
①All visitors should be kept a safe distance from work area.
Keep children away.
②When not in use, machines should be stored in dry and
locked-up place - out of reach of children.
③Wires and Heads should be handled carefully to avoid
accidents and injury.
④During operation, keep your face away from the moving
parts. You may be caught in the moving parts, causing
injury.
⑤ If you have dropped or hit the machine accidentally,
carefully check for damage, crack or deformation.
⑥If you have noticed abnormal state of the machine, ask for
inspection or repair.
CAUTION
①Ware proper apparel.
Wear safety shoes and glasses according to the environment.
②Connect Wire and Head properly. You cannot clean pipes
or Head may be dropped in pipe if not connected properly.
③Do not pull out Wire any more if you find “red mark” on
Wire. It shows the end of Wire.
④ Do not rotate Wire before tightening chuck to hold Wire.
Wire will be twisted and it may cause accident and injury.
⑤Use Safety Glove exclusive for drain cleaning. Unsuitable
gloves may be caught by rotating parts leading to accidents.
■SPECIFICATIONS
Code No. Item Capacity Length of Wire Weight
DH75B Drain Cleaner H-75 Bulb 20~75mm φ8mm×8m(Bulb Head) 2.8kg
DH75D Drain Cleaner H-75 Drop 20~75mm φ8mm×8m(Drop Head) 2.8kg
DH150 Drain Cleaner H-150 20~100mm φ10mm×15.5m(Universal)) 10.2kg
■WIRE
●
Bulb Head Wire
A barrel type Head is suitable for small
pipes.
●
Drop Head Wire
Suitable for small winding pipes
●
Universal Wire
4 types of Head can be changed depending on
the condition.
■HEAD
●
Funnel Head
Suitable to remove vegetables, ra
gs, papers, hairs, etc.
●
Wire Brush
Suitable to remove sands, rust, sc
ales, etc.
●
Grease Cutter
Suitable to remove grease, la
rd, etc.
●
Bulb Head
Suitable for small pipes
■STANDARD ACCESSORIES(●) AND OPTIONAL ACCESSORIES(○)
H-75
Code No. Item Size Bulb Drop H-150
DH301 Bulb Head Wire φ8×8m ● ○
DH309 Bulb Head Wire φ8×15.5m ○
DH310 Bulb Head Wire φ8×20m ○
DH302 Drop Head Wire φ8×8m ●
DH317 Drop Head Wire φ8×15.5m ○
DH318 Drop Head Wire φ8×20m ○
DH304 Universal Wire φ10×8m ○
DH303 Universal Wire φ10×15.5m ●
DH321 Universal Wire φ10×20m ○
48608 φ15mm ○
48606 Drop Head φ24mm ○
48609 φ24mm ○
48610 φ32mm ●
48611 φ38mm ○
48612
Funnel Head
φ60mm ●
48601 Bulb Head φ24mm ○
48613 φ22mm ○
48616 φ36mm ○
48617
Grease Cutter
φ62mm ○
48602 Double Grease Cutter φ40mm ○
48618 φ20mm ○
49619 φ30mm ○
48626 φ40mm ○
48620
Wire Brush
φ50mm ○
70135 Wire Key ●
■SUITABLE SIZE OF HEAD (H-150) *For reference only
Head 1”~ 1.1/4”~ 1.1/2”~ 2”~ 2.1/2”~ 3”~
Funnel Head φ24mm φ32mm φ38mm φ60mm
Bulb Head φ24mm
Grease Cutter φ22mm φ36mm φ62mm
Double Grease Cutter φ40mm
Drop Head φ15mmφ24mm
Wire Brush φ20mm φ30mm φ40mm φ50mm
■HOW TO CHANGE HEAD (H-150)
①To couple Head and Wire, simply slide male
・ to female・.
They are locked with male pin.
②To disconnect, insert Wire Key・ and slide
apart male and female.
③Wires are male and Heads are female.
Pipe