logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ashly
  6. •
  7. Computer Hardware
  8. •
  9. Ashly PE-1200 User manual

Ashly PE-1200 User manual

Other manuals for PE-1200

1

This manual suits for next models

7

Other Ashly Computer Hardware manuals

Ashly AMPLIFIER pne-c2 User manual

Ashly

Ashly AMPLIFIER pne-c2 User manual

Ashly Protea 24.24M User manual

Ashly

Ashly Protea 24.24M User manual

Ashly Keyboard Input Processor SC-44 User manual

Ashly

Ashly Keyboard Input Processor SC-44 User manual

Ashly Protea 3.6SP User manual

Ashly

Ashly Protea 3.6SP User manual

Ashly ne4400 User manual

Ashly

Ashly ne4400 User manual

Ashly ne24.24M User manual

Ashly

Ashly ne24.24M User manual

Ashly 24.24M Quick start guide

Ashly

Ashly 24.24M Quick start guide

Ashly Protea 24.24M User manual

Ashly

Ashly Protea 24.24M User manual

Ashly SWAMP 4-8SP User manual

Ashly

Ashly SWAMP 4-8SP User manual

Ashly ne4400 User manual

Ashly

Ashly ne4400 User manual

Ashly Protea NE4250 User manual

Ashly

Ashly Protea NE4250 User manual

Ashly NE8800S User manual

Ashly

Ashly NE8800S User manual

Ashly Protea DSP480 User manual

Ashly

Ashly Protea DSP480 User manual

Ashly Protea WR-1 Instruction Manual

Ashly

Ashly Protea WR-1 Instruction Manual

Popular Computer Hardware manuals by other brands

EMC2 VNX Series Hardware Information Guide

EMC2

EMC2 VNX Series Hardware Information Guide

Panasonic DV0PM20105 Operation manual

Panasonic

Panasonic DV0PM20105 Operation manual

Mitsubishi Electric Q81BD-J61BT11 user manual

Mitsubishi Electric

Mitsubishi Electric Q81BD-J61BT11 user manual

Gigabyte B660M DS3H AX DDR4 user manual

Gigabyte

Gigabyte B660M DS3H AX DDR4 user manual

Raidon iT2300 Quick installation guide

Raidon

Raidon iT2300 Quick installation guide

National Instruments PXI-8186 user manual

National Instruments

National Instruments PXI-8186 user manual

Hauppauge WinTV-HVR-2250 Quick installation guide

Hauppauge

Hauppauge WinTV-HVR-2250 Quick installation guide

Kontron CP6002 user guide

Kontron

Kontron CP6002 user guide

Manhattan 702843 user manual

Manhattan

Manhattan 702843 user manual

Aphex 230 instruction manual

Aphex

Aphex 230 instruction manual

Intel NUC 12 Pro user guide

Intel

Intel NUC 12 Pro user guide

Galaxy GHDX2-2430S-24F4D Installation and hardware reference manual

Galaxy

Galaxy GHDX2-2430S-24F4D Installation and hardware reference manual

Intel AXXRMFBU4 Quick installation user's guide

Intel

Intel AXXRMFBU4 Quick installation user's guide

Kontron DIMM-PC/MD product manual

Kontron

Kontron DIMM-PC/MD product manual

ST X-NUCLEO-SAFEA1B How to use

ST

ST X-NUCLEO-SAFEA1B How to use

STEINWAY LYNGDORF SP-1 installation manual

STEINWAY LYNGDORF

STEINWAY LYNGDORF SP-1 installation manual

Advantech ASMB-935 Series user manual

Advantech

Advantech ASMB-935 Series user manual

Jupiter RAM PACK instructions

Jupiter

Jupiter RAM PACK instructions

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Preset, Remote & Standby Wiring
Specifications
Optional Proteane DSP Input Card
Latency Analog - 1.512 ms at 48KHz sampling.
Digital - 0.784 ms at 96KHz sampling.
A/D, D/A Converters: 24-bit
DSP 32-bit, floating-point
Digital Input Type AES/EBU 24 bit 44.1 to 96KHz
Signal Flow Architecture "Click and hot plug" flexible architecture, non-
compiling
Available Processing Blocks
Equalization Parametric, Notch, Graphic, Shelving, HPF/LPF, All
pass, Bandpass
Signal Delay Up to 967msec any input/output
HPF/LPF Up to 8th order (48 dB/octave)
Compressor/Limiter, Gate, Meter
Signal Generator Pink noise, White Noise, Sine Wave
Level Control With or without DVCA subgrouping
Ashly Audio Inc.
847 Holt Road, Webster, NY 14580-9103
Toll Free (800) 828-6308, Tel (585) 872-0010, FAX (585) 872-0739
www.ashly.com
All Trademarks referred to herein, are the property of their respective owners.
PE-Series Amplifiers
Proteane DSP Option Cards
Installation and User Guide
Copyright© 2006 – Ashly Audio Inc. All Rights Reserved
Rev 1.2 1007
PE DSP
The Proteane-DSP cards are only for use in Ashly PE-Series (Protea
Enabled) amplifiers. The DSP-1 and DSP-2 cards offer a wide range
of digital features that extend the functionality of your PE-Series
amplifier.
Installation
If the Proteane-DSP Option Card was ordered with your amplifier, no
installation is necessary. If you are retrofitting it to a PE-Series
amplifier that you own already, follow these steps:
1. Disconnect the amplifier mains as well as all inputs and
outputs
2. Remove the 4 screws on the Standard Input card
3. Carefully pull the Standard Input card from the chassis
4. Remove the internal connectors from the Standard Input card
5. Reconnect the internal connectors to the Proteane-DSP Option
Card
6. Carefully slide the new card into the chassis
7. Replace the screws, inputs, outputs and mains
You can now power-up your amplifier and use your new card. If you
are not comfortable performing this installation, refer this task to an
authorized Ashly service provider.
The Proteane software is on the CD shipped with your amplifier. Check
www.ashly.com for software and firmware updates.
Features
Both Proteane-DSP Option Cards offer the same features, with different
connectors. The cards provide both AES/EBU digital inputs as well as
standard analog inputs.
Internal digital processing setup is accomplished via Ashly Proteane
software connected through the 10/100 Ethernet connector. To
maximize your investment in a Proteane-DSP Option Card, two
additional “processed” output connectors are provided to drive
additional amplifier channels.
Panel Details
1. Balanced Inputs – On the DSP-1, these inputs are standard female XLR connectors.
On the DSP-2 these inputs are via 3-pin Euroblock grounded connectors.
2. Processed Channel Outputs – These connectors provide processed signal to additional
amplifiers via male XLR connectors (DSP-1) or Euroblock connectors (DSP-2).
3. Ethernet Connector & Indicators – The 10/100 Ethernet connector interfaces with a
Protea NE network, or computer if available. The indicators show network link and data
activity. All DSP control is via this interface and Protea software on a connected PC.
4. Preset Recall, Remote Standby & Remote Level Control Connector – This
connector facilitates hard-wired preset recall (as set in in Protea software), remote
standby and remote attenuation control. See wiring diagram on the next page for
connection and contact closure information
5. AES/EBU Input Connector – This connector accepts a standard AES/EBU digital
signal at 44.1 to 96 KHz