ASI three 60 Operating and maintenance manual

INSTRUCTIONAL MANUAL
ASI
Life Sciences
Three60 Valve Instructions
Pinch and Cut Disconnect Instructions
Single-Use Aseptic Sampling System

THREE60 SAMPLING SYSTEM VALVE INSTRUCTIONS
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE
• Remove sample system from sterile
package.
• Apply a gasket, Three 60 unit and clamp
to angeinterfaceofyourvessel(1½”
sanitary connector or a NA port).
• Position valve with white depressible
tab pointing upward and the turn arrow
pointing clockwise for easy push and
turn operations.
• Conductyour“steaminplace”or“clean
in place”process.
Step 1: Installation of Unit
With the three60 system, there are no parts to be assembled,
disassembled or cleaned and unlike other single-use sampling systems,
no additional tools are needed. The entire set can be easily applied
toyouruidholdingvesselortransferlineandfoursamplescanbe
removed in only a few minutes.
three60iscompatibletoyourvesselwitheitheraNAportora1½”
sanitary connector; no expensive hardware is needed. Each three60
package contains a valve and four assemblies with Pinch and Cut
Disconnections.

THREE60 SAMPLING SYSTEM INSTRUCTIONS | 3
• When you’re ready to take a sample, slightly
depress tab feature and begin to turn main
body clockwise.
CAUTION: Excessive pressure on the tab may
cause damage and compromise the locking
action.
• Once the turn is initiated, release the tab;
the tab will lock when the open position is
reached. Immediately release the tab, as it will
lockwhentheopenowpositionisreached.
CAUTION: Holding tab as you turn may cause
turning past the ow opening.
• Fill product to the volume desired. For 250 ml
or heavier samples, support the bag with your
hand.
CAUTION: Observe the speed of lling to
avoid overlling.
Step 1: Installation of Unit
Step 2: Start Sampling
• Whensamplelliscomplete,pressthe
depressible tab and again grip and turn the
body clockwise.
• Again, release the tab immediately when
the turn is initiated; valve will lock in to place
when the next closed position is reached.
Step 3: Close Sampling

PINCH AND CUT DISCONNECTION
The Pinch and Cut Disconnection is the answer to the industry’s need
for a simple method of sealing and disconnecting a tube. With only the
operator’s hands, the device will pinch the tube closed, seal the tube
endsand“cut”themapart;thusenablingaquickdisconnectionofthe
sample bag.
PRE-USE DIRECTIONS
Check the clamps to ensure they are not pinching the tubing and
cuttingofftheowpathbygentlypullingeachclampupward,butnot
disconnectingthem.ThePinchandCutisnowreadyforuidtransfer.
PINCH AND CUT DIRECTIONS
1) First,aftertheuidtransferiscomplete,usingbothhands,gripthe
cutting clamp closest to the sample bag and press down until the audible
click is heard and the top rests on the lip.
NOTE: It is CRUCIAL that the clamp closest to the sample bag is
engaged rst.
2) Repeat the same action as step one with the clamp closest to the valve.
3) When you are sure the lock has engaged, grip the clamps with both
hands and the “V” facing you.
4) Press thumbs towards each other. This action will break the clamps to
allow separation. Continue the motion until the tube separates. The clamp
is permanently closed and integrally sealed.

THREE60 SAMPLING SYSTEM INSTRUCTIONS | 5
1.
2.
3.
4.

THREE 60 SINGLE-USE ASEPTIC SAMPLING SYSTEM
TAKING A SAMPLE MADE TO BE SIMPLE
The simple design behind the three60 Sampling System allows you to take a
representative sample of your product with minimal effort.
For a completely sterile transfer, use a CIP or SIP process to prepare your tank.
Thepre-irradiatedbagsandassemblieswillensureasterileuidpathwhile
thequick-turnvalveandPinchandCutDisconnectionsmaintainsteriletransfer
and removal.
SINGLE-USE SOLUTIONS
Single-use systems are providing improved sterility and reduced cleaning
requirementsovertraditionalsamplingsystemsacrossallapplicationsinthe
Bio-Pharmaceutical Industry.
The three60 Single-Use System brings the same advantages to sampling
resultinginaquickersolutionandasaferprocess.
EFFICIENT
With the three60 system, there are no parts to be assembled, disassembled
or cleaned and unlike other single-use sampling systems, no additional tools
areneeded.Theentiresetcanbeeasilyappliedtoyouruidholdingvesselor
transfer line and four samples can be removed in only a few minutes.
three60iscompatibletoyourvesselwitheitheraNAportora1½”sanitary
connector; no expensive hardware is needed. Each three60 package contains a
valve and four assemblies with Pinch and Cut Disconnections.
ASI |163ResearchLane,Millersburg,PA|(717)692-2104|(800)724-4158|www.asisus.com
ASIisanFDARegistered,ISO13485:2003CertiedManufacturer
RevC01-17-2013PK-01195
ASI
Life Sciences
Table of contents
Popular Sampler manuals by other brands

Novation
Novation Circuit Rhythm user guide

ELMACRON
ELMACRON VA/V3 manual

Sibata
Sibata DAS-100 Operation manual

Particle Measuring Systems
Particle Measuring Systems MiniCapt 100R Operation manual

Lighthouse
Lighthouse ActiveCount100 Operator's manual

YZ Systems
YZ Systems DynaPak DP-2010RN Instructions & operating manual