ASKOHEAT-F+ Flange heater Ø 180mm
MV-012-6791.2 01.11.2021 www.askoma.com Page 3
Operating instructions
Important information
If a heat exchanger is ed in the same tank, the controller must limit the temperature caused by the
heat exchanger to 85°C. This prevents the safety temperature limiter of the ange heater tripping.
Safety temp erature limiter
The safety temperature limiter may trip at temperatures lower than approx. –15°C (e. g. transportaon
or storage). If this happens, press the reset buon, see page 6 “user manual”.
The device may o nly be used to h eat water.
Corrosion protection
Please note: This heang element is applicable in stainless steel boiler as well as in black steel / black
steel enamelled boilers. Select the sengs via DIP switch according to the boiler type.
For an installaon of the heang element into black steel or black steel enamelled boilers, the red slide
switch (DIP switch) has to be le in posion “Schwarzstahlspeicher” (factory seng).
When installing the heang element into a stainless steel or chrome steel boiler, the slide switch
(DIP switch) has to be switched to posion “Edelstahlspeicher”.
Electri cal connection
The device is intended for xed connecon only and may be connected only to xed cables. Select a
cable cross-secon suitable for the power rang of the device. All poles of the device must be able to
be disconnected from the mains by means of an at least 3mm isolang distance. The PE wire must be
100mm longer than the other conductors.
In the event of the following the guarantee is vo id:
- Not complying with this paperwork „Fing instrucons, user manual, and service“
- Not complying with the storage heater manufacturer's ng instrucons
- Technical modicaons, repairs or tampering with the device (including exchanging the thermostat)
- Applicaons for which the device was not designed
- Incorrect operaon and maintenance
- Not complying with direcve VDI 2035
- Manipulaons on the operang soware
- Undocumented parameterizaons via the documented interfaces