HMI VICTORIA PLUS SILENT VS CONTROL PANEL - INSTRUCTION MANUAL
4
ENGLISH
HOW TO USE THE CONTROL PANEL
The Victoria Plus Silent VS variable speed pump has a control panel for switching the pump on and
off, and for adjusting and displaying the pump’s settings and configuration.
CONTROL KEYS:
1On/Off: Press the button to switch the pump on or off. The pump will always start in the same mode and
with the same configuration as when it was last switched off.
When the off button is pressed, the message “OFF” will be displayed on the screen for 2 minutes.
2Auto Mode: Press the button so that the pump connects and disconnects in AUTO Mode at the setpoint
Times and Speeds.
3Settings: Press the button to enter the Settings Menu. The Settings Menu can be accessed both when
the pump is on or off, provided it is plugged in.
4Exit: In the Settings Menu, press the button to exit without saving your changes. Every press of the button
will go back one step in the Settings Menu.
5Enter: In the Settings Menu, press the button to enter the option selected or to accept/save changes
made to the settings.
6Setpoint Mode. Low Speed: Press the button so that the pump runs or starts up at Low Speed (by
default, 1,400 rpm).
7Setpoint Mode. Medium speed: Press the button so that the pump runs or starts up at Medium Speed
(by default, 2,100 rpm).
8Setpoint Mode. High speed: Press the button so that the pump runs or starts up at High Speed (by
default, 2,750 rpm).
9Setpoint Mode. Turbo Speed: Press the button so that the pump runs or starts up in Manual Mode at
Turbo Speed. This mode is used for self-priming, fast cleaning, etc. (by default 3,025 rpm). The Manual
Mode at Turbo Speed lasts a set time that once over will automatically go into Manual Mode at High
Speed.
10 Arrow buttons: Browsing, selection and settings buttons.
Up arrow: In the Settings Menu, this arrow increases the value of the setting selected or goes on to the next
option. If you wish to increase the value selected without stopping, keep the button pressed down
for more than 3 seconds and release it when the desired value has been reached.
This arrow also starts the pump in Manual Mode when it is in Standby Mode or in Auto
Mode and increases the running speed.
Down arrow: In the Settings Menu, this arrow decreases the value of the setting selected or goes back to
the previous option. If you wish to decrease the value selected without stopping, keep the button
pressed down for more than 3 seconds and release it when the desired value has been reached.
This arrow also starts the pump in Manual Mode when it is in Standby Mode or in Auto
Mode and decreases the running speed.
Left arrow: This arrow scrolls through the options on the left of the Settings Menu or goes forward through
the options in the Settings Menu.
Right arrow: This arrow scrolls through the options on the right of the Settings Menu or goes backward through
the options in the Settings Menu.